Role of environmental surveillance in determining the risk of hospital-acquired legionellosis: A national surveillance study with clinical correlations

被引:107
作者
Stout, Janet E.
Muder, Robert R.
Mietzner, Sue
Wagener, Marilyn M.
Perri, Mary Beth
DeRoos, Kathleen
Goodrich, Dona
Arnold, William
Williamson, Theresa
Ruark, Ola
Treadway, Christine
Eckstein, Elizabeth C.
Marshall, Debra
Rafferty, Mary Ellen
Sarro, Kathleen
Page, Joann
Jenkins, Robert
Oda, Gina
Shimoda, Kathleen J.
Zervos, Marcus J.
Bittner, Marvin
Camhi, Sharon L.
Panwalker, Anand P.
Donskey, Curtis J.
Nguyen, Minh-Hong
Holodniy, Mark
Yu, Victor L.
机构
[1] Univ Pittsburgh, VA Pittsburgh Healthcare Syst, Pittsburgh, PA 15260 USA
[2] Vet Affairs Med Ctr, Butler, PA USA
[3] William Beaumont Hosp, Royal Oak, MI 48072 USA
[4] Vet Affairs Med Ctr, Omaha, NE USA
[5] So Arizona Healthcare Syst, Tucson, AZ USA
[6] Vet Affairs Med Ctr, Wilmington, DE USA
[7] Louis Stokes Vet Affairs Med Ctr, Cleveland, OH USA
[8] Vet Affairs Med Ctr, Dayton, OH USA
[9] Stratton Vet Affairs Med Ctr, Albany, NY USA
[10] Vet Affairs Med Ctr, Iowa City, IA USA
[11] Vet Affairs Med Ctr, Gainesville, FL 32608 USA
[12] Vet Affairs Med Ctr, Palo Alto, CA USA
[13] Vet Affairs Med Ctr, Long Beach, CA USA
关键词
D O I
10.1086/518754
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objective. Hospital-acquired Legionella pneumonia has a fatality rate of 28%, and the source is the water distribution system. Two prevention strategies have been advocated. One approach to prevention is clinical surveillance for disease without routine environmental monitoring. Another approach recommends environmental monitoring even in the absence of known cases of Legionella pneumonia. We determined the Legionella colonization status of water systems in hospitals to establish whether the results of environmental surveillance correlated with discovery of disease. None of these hospitals had previously experienced endemic hospital-acquired Legionella pneumonia. Design. Cohort study. kll;llSetting. Twenty US hospitals in 13 states. Interventions. Hospitals performed clinical and environmental surveillance for Legionella from 2000 through 2002. All specimens were shipped to the Special Pathogens Laboratory at the Veterans Affairs Pittsburgh Medical Center. Results. Legionella pneumophila and Legionella anisa were isolated from 14 (70%) of 20 hospital water systems. Of 676 environmental samples, 198 (29%) were positive for Legionella species. High-level colonization of the water system (30% or more of the distal outlets were positive for L. pneumophila) was demonstrated for 6 (43%) of the 14 hospitals with positive findings. L. pneumophila serogroup 1 was detected in 5 of these 6 hospitals, whereas 1 hospital was colonized with L. pneumophila serogroup 5. A total of 633 patients were evaluated for Legionella pneumonia from 12 (60%) of the 20 hospitals: 377 by urinary antigen testing and 577 by sputum culture. Hospital-acquired Legionella pneumonia was identified in 4 hospitals, all of which were hospitals with L. pneumophila serogroup 1 found in 30% or more of the distal outlets. No cases of disease due to other serogroups or species (L. anisa) were identified. Conclusion. Environmental monitoring followed by clinical surveillance was successful in uncovering previously unrecognized cases of hospital-acquired Legionella pneumonia.
引用
收藏
页码:818 / 824
页数:7
相关论文
共 36 条
[1]  
Allegheny County Health Department, 1997, APPR PREV CONTR LEG
[2]  
Tablan Ofelia C, 2004, MMWR Recomm Rep, V53, P1
[3]   Trends in legionnaires disease, 1980-1998: Declining mortality and new patterns of diagnosis [J].
Benin, AL ;
Benson, RF ;
Besser, RE .
CLINICAL INFECTIOUS DISEASES, 2002, 35 (09) :1039-1046
[4]  
BEST M, 1983, LANCET, V2, P307
[5]   Prospective 3-year surveillance for nosocomial and environmental Legionella pneumophila:: Implications for infection control [J].
Boccia, S. ;
Laurenti, P. ;
Borella, P. ;
Moscato, U. ;
Capalbo, G. ;
Cambieri, A. ;
Amore, R. ;
Quaranta, G. ;
Boninti, F. ;
Orsini, M. ;
Branca, G. ;
Fadda, G. ;
Spica, V. Romano ;
Ricciardi, G. .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2006, 27 (05) :459-465
[6]   Issues in the control of nosocomial legionellosis [J].
Butler, JC ;
Fields, BS ;
Breiman, RF .
INFECTIOUS DISEASES IN CLINICAL PRACTICE, 1998, 7 (02) :117-118
[7]   Prevention and control of legionellosis [J].
Butler, JC ;
Fields, BS ;
Breiman, RF .
INFECTIOUS DISEASES IN CLINICAL PRACTICE, 1997, 6 (07) :458-464
[8]  
Centers for Disease Control and Prevention, 1997, MMWR Morb Mortal Wkly Rep., V46, P31
[9]   Nosocomial legionnaires' disease caused by Legionella pneumophila serogroup 5: Laboratory and epidemiologic implications [J].
Chang, FY ;
Jacobs, SL ;
Colodny, SM ;
Stout, JE ;
Yu, VL .
JOURNAL OF INFECTIOUS DISEASES, 1996, 174 (05) :1116-1119
[10]   Clinical and environmental distributions of Legionella strains in France are different [J].
Doleans, A ;
Aurell, H ;
Reyrolle, M ;
Lina, G ;
Freney, J ;
Vandenesch, F ;
Etienne, J ;
Jarraud, S .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (01) :458-460