It is extensively well-known that Ni and other metals occurring as impurities in cosmetic products might give rise to contact dermatitis in subjects with pre-existing allergy. The present study on the content of 13 metals (Cd, Co, Cr, Cu, Hg, Ir, Mn, Ni, Pb, Pd, Pt, Rh, and V) in moisturizing creams, labelled as "Ni-tested" (i.e., Ni content < 100 ng g(-1)) and available on the Italian market, provides a basis for assessing their safety for consumers. Quantification of metals was performed by sector field inductively coupled plasma mass spectrometry after microwave-assisted acid digestion of products. The developed method had limits of quantification less than 0.8 ng g(-1) for all the elements; recovery was in the interval 88% (Cd, Cc) to 110% (Hg), and precision was always under 7%. Nickel was present in all the products with levels between 17.5 and 153 ng g(-1); three skin creams were slightly above the concentration reported on the label. The other elements were at levels below 1 mu g g(-1). The highest concentrations, in ng g(-1), of Co, Cr, Cu, and Mn were 222, 303, 51.2, and 59.9, respectively. Mean Cd, Pb, and V were below 5 ng g(-1), while Hg was absent in all the samples. Among the new emergent allergens, Ir and Rh were in traces or even undetectable, while Pt had levels of 2.65 and 6.28 ng g(-1) in two creams and Pd was equal to 1.07 ng g(-1) in one product. The overall results are below the sensitizing limit proposed for consumer products and, thus, probably have no significant toxicological effects. Nevertheless, some creams presented amounts of Co and Cr comparable to those of Ni and therefore they have to be monitored in consideration of their cross-reactivity as well. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1197 / 1202
页数:6
相关论文
共 34 条
  • [1] AN ARM IMMERSION MODEL OF COMPROMISED SKIN .2. INFLUENCE ON MINIMAL ELICITING PATCH TEST CONCENTRATIONS OF NICKEL
    ALLENBY, CF
    BASKETTER, DA
    [J]. CONTACT DERMATITIS, 1993, 28 (03) : 129 - 133
  • [2] NICKEL, COBALT AND CHROMIUM IN CONSUMER PRODUCTS - A ROLE IN ALLERGIC CONTACT-DERMATITIS
    BASKETTER, DA
    BRIATICOVANGOSA, G
    KAESTNER, W
    LALLY, C
    BONTINCK, WJ
    [J]. CONTACT DERMATITIS, 1993, 28 (01) : 15 - 25
  • [3] Nickel, chromium and cobalt in consumer products:: revisiting safe levels in the new millennium
    Basketter, DA
    Angelini, G
    Ingber, A
    Kern, PS
    Menné, T
    [J]. CONTACT DERMATITIS, 2003, 49 (01) : 1 - 7
  • [4] High-throughput microwave-digestion procedures to monitor neurotoxic elements in body fluids by means of inductively coupled plasma mass spectrometry
    Bocca, B
    Alimonti, A
    Forte, G
    Petrucci, F
    Pirola, C
    Senofonte, O
    Violante, N
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (01) : 65 - 70
  • [5] Nickel quantification in serum by a validated sector-field inductively coupled plasma mass spectrometry method: assessment of tentative reference values for an Italian population
    Bocca, Beatrice
    Forte, Giovanni
    Ronchi, Anna
    Gaggeri, Raffaella
    Alimonti, Alessandro
    Minoia, Claudio
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (22) : 3289 - 3294
  • [6] Ciaralli L, 1996, Ann Ist Super Sanita, V32, P381
  • [7] Conti M., 1996, J APPL COSMETOL, V14, P147
  • [8] EBNER H, 1978, WIEN KLIN WOCHENSCHR, V90, P311
  • [9] EC, 1994, OFF J EUR COMM L, P1
  • [10] Fowler JF, 1998, CURR PROBL DERM-US, V10, P216