High performance CCD camera system for digitalisation of 2D DIGE gels

被引:7
|
作者
Strijkstra, Annemieke [1 ,2 ]
Trautwein, Kathleen [1 ,2 ]
Roesler, Stefan [3 ]
Feenders, Christoph [4 ]
Danzer, Daniel [3 ]
Riemenschneider, Udo [3 ]
Blasius, Bernd [4 ]
Rabus, Ralf [1 ,2 ]
机构
[1] Carl von Ossietzky Univ Oldenburg, Gen & Mol Microbiol, Inst Chem & Biol Marine Environm ICBM, Carl von Ossietzky Str 9-11, D-26111 Oldenburg, Germany
[2] Max Planck Inst Marine Mikrobiol, Dept Microbiol, Bremen, Germany
[3] Intas Sci Imaging Instruments GmbH, Gottingen, Germany
[4] Carl von Ossietzky Univ Oldenburg, Math Modelling, Inst Chem & Biol Marine Environm ICBM, Oldenburg, Germany
关键词
2D DIGE; CCD camera; Laser scanner; Intas Advanced 2D Imager; Technology; Typhoon; MARINE;
D O I
10.1002/pmic.201500385
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An essential step in 2D DIGE-based analysis of differential proteome profiles is the accurate and sensitive digitalisation of 2D DIGE gels. The performance progress of commercially available charge-coupled device (CCD) camera-based systems combined with light emitting diodes (LED) opens up a new possibility for this type of digitalisation. Here, we assessed the performance of a CCD camera system (Intas Advanced 2D Imager) as alternative to a traditionally employed, high-end laser scanner system (Typhoon 9400) for digitalisation of differential protein profiles from three different environmental bacteria. Overall, the performance of the CCD camera system was comparable to the laser scanner, as evident from very similar protein abundance changes (irrespective of spot position and volume), as well as from linear range and limit of detection.
引用
收藏
页码:1975 / 1979
页数:5
相关论文
共 50 条
  • [1] 2D DIGE
    Lilley, K. S.
    Karp, N. A.
    Griffin, J. L.
    Borner, G. H. H.
    Weimar, T.
    Dupree, P.
    COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-MOLECULAR & INTEGRATIVE PHYSIOLOGY, 2005, 141 (03): : S248 - S248
  • [2] Quantitative evaluation of 2D chromatograms with a CCD camera
    Petrovic, M
    Kastelan-Macan, M
    Babic, S
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 1998, 11 (05) : 353 - 356
  • [3] State of the art of 2D DIGE
    Arentz, Georgia
    Weiland, Florian
    Oehler, Martin K.
    Hoffmann, Peter
    PROTEOMICS CLINICAL APPLICATIONS, 2015, 9 (3-4) : 277 - 288
  • [4] High performance, dual speed CCD camera system for scientific imaging
    Simpson, RW
    SOLID STATE SENSOR ARRAYS AND CCD CAMERAS, 1996, 2654 : 259 - 265
  • [5] The development of the DIGE system: 2D fluorescence difference gel analysis technology
    Marouga, R
    David, S
    Hawkins, E
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (03) : 669 - 678
  • [6] Line-scan CCD camera calibration in 2D coordinate measurement
    Ma, Weihong
    Dong, Tao
    Tian, Hui
    Ni, Jinping
    OPTIK, 2014, 125 (17): : 4795 - 4798
  • [7] The development of the DIGE system: 2D fluorescence difference gel analysis technology
    Rita Marouga
    Stephen David
    Edward Hawkins
    Analytical and Bioanalytical Chemistry, 2005, 382 : 669 - 678
  • [8] Performance of Mobile Camera on Colour 2D Barcode
    Ong, Siong Khai
    Chai, Douglas
    Tan, Keng T.
    2009 INTERNATIONAL SYMPOSIUM ON INTELLIGENT SIGNAL PROCESSING AND COMMUNICATION SYSTEMS (ISPACS 2009), 2009, : 497 - 500
  • [9] Performance evaluation of high resolution CCD image sensor and CCD camera
    Tan, Xinquan
    Mei, Xiaoying
    Guangxue Jishu/Optical Technique, 1999, (01): : 70 - 72
  • [10] 2D gels are not enough
    William Wells
    Genome Biology, 1 (1)