First Steps Towards an Implantable Electromyography (EMG) Sensor Powered and Controlled by Galvanic Coupling

被引:4
作者
Becerra-Fajardo, Laura [1 ]
Ivorra, Antoni [1 ,2 ]
机构
[1] Univ Pompeu Fabra, Dept Informat & Commun Technol, Barcelona 08018, Spain
[2] Univ Pompeu Fabra, Barcelona 08018, Spain
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3 | 2019年 / 68卷 / 03期
基金
欧洲研究理事会;
关键词
Galvanic coupling; Microsensors; Microstimulator;
D O I
10.1007/978-981-10-9023-3_4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the past it has been proposed to use implanted electromyography (EMG) sensors for myoelectric control. In contrast to surface systems, these implanted sensors provide signals with low cross-talk. To achieve this, miniature implantable devices that acquire and transmit real-time EMG signals are necessary. We have recently in vivo demonstrated electronic implants for electrical stimulation which can be safely powered and independently addressed by means of galvanic coupling. Since these implants lack bulky components as coils and batteries, we anticipate it will be possible to accomplish very thin implants to be massively deployed in tissues. We have also shown that these devices can have bidirectional communication. The aim of this work is to demonstrate a circuit architecture for embedding EMG sensing capabilities in our galvanically powered implants. The circuit was simulated using intramuscular EMG signals obtained from an analytical infinite volume conductor model that used a similar implant configuration. The simulations showed that the proposed analog front-end is compatible with the galvanic powering scheme and does not affect the implant's ability to perform electrical stimulation. The system has a bandwidth of 958 Hz, an amplification gain of 45 dB, and an output-referred noise of 160 mu V-rms. The proposed embedded EMG sensing capabilities will boost the use of these galvanically powered implants for diagnosis, and closed-loop control.
引用
收藏
页码:19 / 22
页数:4
相关论文
共 8 条
[1]   Demonstration of 2 mm Thick Microcontrolled Injectable Stimulators Based on Rectification of High Frequency Current Bursts [J].
Becerra-Fajardo, Laura ;
Schmidbauer, Marieluise ;
Ivorra, Antoni .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2017, 25 (08) :1343-1352
[2]  
Becerra-Fajardo L, 2015, I IEEE EMBS C NEUR E, P545, DOI 10.1109/NER.2015.7146680
[3]   The dielectric properties of biological tissues .3. Parametric models for the dielectric spectrum of tissues [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2271-2293
[4]   Remote Electrical Stimulation by Means of Implanted Rectifiers [J].
Ivorra, Antoni .
PLOS ONE, 2011, 6 (08)
[5]   Simulation of intramuscular-EMG signals detected using implantable myoelectric sensors (IMES) [J].
Lowery, Madeleine M. ;
Weir, Richard E. ff. ;
Kuiken, Todd A. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (10) :1926-1933
[6]   Implanted Neuroprosthesis for Restoring Arm and Hand Function in People With High Level Tetraplegia [J].
Memberg, William D. ;
Polasek, Katharine H. ;
Hart, Ronald L. ;
Bryden, Anne M. ;
Kilgore, Kevin L. ;
Nemunaitis, Gregory A. ;
Hoyen, Harry A. ;
Keith, Michael W. ;
Kirsch, Robert F. .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2014, 95 (06) :1201-1211
[7]   Rehabilitation Exoskeletal Robotics The Promise of an Emerging Field [J].
Pons, Jose L. .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2010, 29 (03) :57-63
[8]   Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording [J].
Weir, Richard E. Ff ;
Troyk, Phil R. ;
DeMichele, Glen A. ;
Kerns, Douglas A. ;
Schorsch, Jack F. ;
Maas, Huub .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (01) :159-171