Effect of different design of abutment and implant on stress distribution in 2 implants and peripheral bone: A finite element analysis study

被引:19
作者
Kul, Esra [1 ]
Korkmaz, Ismail Hakki [2 ]
机构
[1] Ataturk Univ, Dept Prosthodont, Fac Dent, Erzurum, Turkey
[2] Erzurum Tech Univ, Dept Mech Engn, Fac Engn & Architecture, Erzurum, Turkey
关键词
PROSTHESIS; LENGTH; CONNECTIONS; DIAMETER; QUALITY; MAXILLA; MISFIT; FORCES; 3D-FEA;
D O I
10.1016/j.prosdent.2020.09.058
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. How adjacent dental implants with different sizes, designs, and abutment connection shapes affect stress on the prosthetic structure is unclear. Purpose. The purpose of this finite element analysis (FEA) study was to analyze stress distribution around bone and around 2 implants with different sizes, diameters, shapes, and loading directions placed next to each other in splinted and unsplinted prostheses. Material and methods. On 3D FEA models representing the posterior right lateral segment of the mandible, 1 implant (empty set3.5x12 mm) and 1 implant (empty set5.5x8 mm) were placed adjacent. Three different contemporary implant models were created with different teeth, pitch, spiral numbers, and self-taping features, and different abutments for them were modeled in 3D. The implant abutment connection was internal hexagonal (MIH), stepped conical (MSC), and internal conical (MIC). Vertical and oblique loads of 365 N for molar teeth and of 200 N for premolar teeth were applied as boundary conditions to the cusp ridges and grooves in a nonlinear FEA. Results. The MIH implants resulted in improved stress conditions. According to the von Mises stresses occurring on the screw, abutment, and implant, especially under oblique loads, MIH was exposed to less stress than MSC, and MSC was exposed to less stress than MIC. Conclusions. When a standard implant and a short implant were placed adjacent and splinted by crowns, the implants, abutments, and screws had unfavorable stress levels; therefore, adjacent splinted implants should be of similar size. The form of the implant-abutment junction is also an important factor affecting stress.
引用
收藏
页码:664.e1 / 664.e9
页数:9
相关论文
共 35 条
  • [1] Akca K, 2001, Implant Dent, V10, P238
  • [2] Crestal Bone Loss Around Adjacent Dental Implants Restored with Splinted and Nonsplinted Fixed Restorations: A Systematic Literature Review
    Al Amri, Mohammad D.
    Kellesarian, Sergio Varela
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (06): : 495 - 501
  • [3] Tilted and Short Implants Supporting Fixed Prosthesis in an Atrophic Maxilla: A 3D-FEA Biomechanical Evaluation
    Almeida, Erika O.
    Rocha, Eduardo P.
    Freitas Junior, Amilcar C.
    Anchieta, Rodolfo B.
    Poveda, Ronald
    Gupta, Nikhil
    Coelho, Paulo G.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E332 - E342
  • [4] Amid Reza, 2017, J Long Term Eff Med Implants, V27, P1, DOI 10.1615/JLongTermEffMedImplants.2017019926
  • [5] Splinted and Nonsplinted Crowns with Different Implant Lengths in the Posterior Maxilla by Three-Dimensional Finite Element Analysis
    Araujo Lemos, Cleidiel Aparecido
    Verri, Fellippo Ramos
    Santiago Junior, Joel Ferreira
    de Souza Batista, Victor Eduardo
    Kemmoku, Daniel Takanori
    Noritomi, Pedro Yoshito
    Pellizzer, Eduardo Piza
    [J]. JOURNAL OF HEALTHCARE ENGINEERING, 2018, 2018
  • [6] Effect of Superstructure Materials and Misfit on Stress Distribution in a Single Implant-Supported Prosthesis: A Finite Element Analysis
    Assuncao, Wirley Goncalves
    Gomes, Erica Alves
    Ricardo Barao, Valentim Adelino
    Delben, Juliana Aparecida
    Tabata, Lucas Fernando
    Capello de Sousa, Edson Antonio
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (03) : 689 - 695
  • [7] Stress distribution in fixed-partial prosthesis and peri-implant bone tissue with different framework materials and vertical misfit levels: a three-dimensional finite element analysis
    Bacchi, Atais
    Consani, Rafael L. X.
    Mesquita, Marcelo F.
    dos Santos, Mateus B. F.
    [J]. JOURNAL OF ORAL SCIENCE, 2013, 55 (03) : 239 - 244
  • [8] Brunski JB, 2000, INT J ORAL MAX IMPL, V15, P15
  • [9] Mechanical analysis of a dental implant system under 3 contact conditions and with 2 mechanical factors
    Chang, Hung-Chih
    Li, Hung-Yuan
    Chen, Yen-Nien
    Chang, Chih-Han
    Wang, Chau-Hsiang
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (04) : 376 - 382
  • [10] Choi KS., 2012, Int J Oral Maxillofac Implants, V27, P29