A new 'online' method to measure increased exhaled isoprene in end-stage renal failure

被引:75
作者
Davies, S
Spanel, P
Smith, D
机构
[1] Univ Keele, Postgrad Med Sch, Ctr Sci & Technol Med, Stoke On Trent ST4 7QB, Staffs, England
[2] N Staffordshire Hosp, Dept Nephrol, Stoke On Trent, Staffs, England
[3] Acad Sci Czech Republ, J Heyrovsky Inst Phys Chem, CR-18223 Prague 8, Czech Republic
关键词
biocompatibility; breath analysis; haemodialysis; isoprene; SIFT-MS;
D O I
10.1093/ndt/16.4.836
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. Isoprene is the most abundant hydrocarbon present in breath, and recent reports indicate that breath concentrations increase following haemodialysis. The purpose of this study was to establish whether selected ion flow tube mass spectrometry (SIFT-MS), a newly established technique in breath analysis, may be used to quantify breath isoprene in haemodialysis patients in the clinical setting. SIFT-MS is compared and contrasted with the established gas chromatography mass spectrometric technique for this purpose. Methods. Three consecutive exhalations from 19 haemodialysis patients (12 males, seven females) undergoing a morning dialysis shift were analysed just prior to commencing treatment. Within 5 min of completing their usual dialysis regimen, using polysulphone membranes, the breath of each patient was analysed again. Additional contemporary samples were obtained from 17 normal controls. Breath isoprene was quantified using SIFT-MS, a method previously validated quantitatively using neat isoprene. Results. Successful measurements of breath isoprene were obtained for each subject within 2 min, with minimum disruption to a busy dialysis environment. The coefficient of variation of triplicate measurements of breath isoprene was < 10%. Prior to dialysis, the mean (+/- SD) breath isoprene concentration (138 +/- 63 parts per billion (ppb)) was significantly greater than for normal controls (89 +/- 36 ppb; P = 0.016). Immediately following treatment, breath isoprene increased significantly to 184 +/- 95 ppb (P = 0.023). Conclusions. SIFT-MS permits the accurate and rapid measurement of breath isoprene in haemodialysis patients in the clinical setting. The previously reported increase in breath isoprene following dialysis treatment is confirmed. SIFT-MS is the ideal analytical tool to investigate this phenomenon further.
引用
收藏
页码:836 / 839
页数:4
相关论文
共 23 条
  • [1] Volatile alkanes and increased concentrations of isoprene in exhaled air during hemodialysis
    Capodicasa, E
    Trovarelli, G
    De Medio, GE
    Pelli, MA
    Lippi, G
    Verdura, C
    Timio, M
    [J]. NEPHRON, 1999, 82 (04) : 331 - 337
  • [2] Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
    Davies, S
    Spanel, P
    Smith, D
    [J]. KIDNEY INTERNATIONAL, 1997, 52 (01) : 223 - 228
  • [3] Euler DE, 1996, CLIN CHEM, V42, P303
  • [4] Breath isoprene: Temporal changes in respiratory output after exposure to ozone
    Foster, WM
    Jiang, L
    Stetkiewicz, PT
    Risby, TH
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1996, 80 (02) : 706 - 710
  • [5] Hyspler R, 2000, J CHROMATOGR B, V739, P183
  • [6] DETERMINATION OF ISOPRENE IN HUMAN BREATH BY THERMAL-DESORPTION GAS-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION
    JONES, AW
    LAGESSON, V
    TAGESSON, C
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1995, 672 (01): : 1 - 6
  • [7] MENDIS S, 1994, CLIN CHEM, V40, P1485
  • [8] EXPIRED HYDROCARBONS IN PATIENTS WITH ACUTE MYOCARDIAL-INFARCTION
    MENDIS, S
    SOBOTKA, PA
    EULER, DE
    [J]. FREE RADICAL RESEARCH, 1995, 23 (02) : 117 - 122
  • [9] Exhaled isoprene and acetone in newborn infants and in children with diabetes mellitus
    Nelson, N
    Lagesson, V
    Nosratabadi, AR
    Ludvigsson, J
    Tagesson, C
    [J]. PEDIATRIC RESEARCH, 1998, 44 (03) : 363 - 367
  • [10] Application of a new method for analysis of exhaled gas in critically ill patients
    Schubert, JK
    Muller, WPE
    Benzing, A
    Geiger, K
    [J]. INTENSIVE CARE MEDICINE, 1998, 24 (05) : 415 - 421