Nitrate-selective membrane electrode based on bis(2-hydroxyanil)acetylacetone lead(II) neutral carrier

被引:10
|
作者
Asghari, A
Amini, MK [1 ]
Mansour, HR
Salavati-Niasari, M
Rajabi, M
机构
[1] Univ Isfahan, Dept Chem, Esfahan 8174673441, Iran
[2] Univ Kashan, Dept Chem, Kashan, Iran
[3] Isfahan Univ Technol, Coll Chem, Esfahan, Iran
关键词
D O I
10.2116/analsci.19.1121
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A nitrate-selective electrode based on a recently synthesized bis(2-hydroxyanil)acetylacetone lead(II) complex [(haacac)Pb] has been developed. Among different compositions studied, a membrane containing 30.7% poly(vinyl chloride) (PVC), 61.3% dibutyl phthalate (DBP) as a plasticizer, 3% methyltrioctylammonium chloride (MTOAC) as a cationic additive and 5% ionophore (all w/w) exhibited the best potentiometric response toward nitrate ion in aqueous solutions. The potentiometric response of the electrode was linear with a Nemstian slope of -58.8 mV decade(-1) within the NO3- concentration range of 2 x 10(-5) - 1 x 10(-1) mol dm(-3). The response time of the electrode was less than or equal to 10 s over the entire linear concentration range of the calibration plot. The electrode is suitable for use within the pH range of 5.3 - 11. The selectivity coefficients for the proposed electrode were improved for some interferences, when compared with those of commercially available nitrate-selective electrodes.
引用
收藏
页码:1121 / 1125
页数:5
相关论文
共 50 条
  • [1] Nitrate-Selective Membrane Electrode Based on Bis(2-hydroxyanil)acetylacetone Lead(II) Neutral Carrier
    Alireza Asghari
    Mohammad K. Amini
    Hassan R. Mansour
    Masood Salavati-Niasari
    Maryam Rajabi
    Analytical Sciences, 2003, 19 : 1121 - 1126
  • [2] Chronium(III) ion selective electrode based on glyoxal bis(2-hydroxyanil)
    Gholivand, MB
    Sharifpour, F
    TALANTA, 2003, 60 (04) : 707 - 713
  • [3] A tetra-co ordinate nickel(II) complex as neutral carrier for nitrate-selective PVC membrane electrode
    Asghari, AR
    Amini, MK
    Mansour, HR
    Salavati-Niasari, M
    TALANTA, 2003, 61 (04) : 557 - 563
  • [4] A NITRATE-SELECTIVE ELECTRODE BASED ON BIS(TRIPHENYLPHOSPHINE)IMINIUM SALTS
    WERNER, G
    KOLOWOS, I
    SENKYR, J
    TALANTA, 1989, 36 (09) : 966 - 968
  • [5] The electrocatalytic reduction of molecular oxygen with a Co(II)-glyoxal bis(2-hydroxyanil) complex coated electrode
    Jeong, ED
    Won, MS
    Shim, YB
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 1998, 19 (04) : 417 - 422
  • [6] Nitrate-selective electrode based on a cyclic bis-thiourea ionophore
    Watts, Amanda S.
    Gavalas, Vasilis G.
    Cammers, Arthur
    Andrada, Pilar Sanchez
    Alajarin, Mateo
    Bachas, Leonidas G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 121 (01) : 200 - 207
  • [7] XYLENE BIS(DIETHYLDITHIOCARBAMATE) AS A NEUTRAL CARRIER FOR COPPER(II)-SELECTIVE MEMBRANE-ELECTRODE
    KAMATA, S
    OGAWA, F
    FUKUMOTO, M
    CHEMISTRY LETTERS, 1987, (03) : 533 - 534
  • [8] LEAD-SELECTIVE NEUTRAL CARRIER BASED LIQUID MEMBRANE-ELECTRODE
    LINDNER, E
    TOTH, K
    PUNGOR, E
    BEHM, F
    OGGENFUSS, P
    WELTI, DH
    AMMANN, D
    MORF, WE
    PRETSCH, E
    SIMON, W
    ANALYTICAL CHEMISTRY, 1984, 56 (07) : 1127 - 1131
  • [9] LEAD-SELECTIVE MEMBRANE-ELECTRODE USING METHYLENE BIS(DIISOBUTYLDITHIOCARBAMATE) NEUTRAL CARRIER
    KAMATA, S
    ONOYAMA, K
    ANALYTICAL CHEMISTRY, 1991, 63 (13) : 1295 - 1298
  • [10] Bis(2-hydroxyacetophenone)ethylenediimine as a Neutral Carrier in a Coated-Wire Membrane Electrode for Lead(II)
    Mohammad Mazloum Ardakani
    Pouran Pourhakak
    Masoud Salavati-Niasari
    Analytical Sciences, 2006, 22 : 865 - 870