Corneal Biomechanical Comparison of Pseudoexfoliation Syndrome, Pseudoexfoliative Glaucoma and Healthy Subjects

被引:24
作者
Yazgan, Serpil [1 ]
Celik, Ugur [2 ]
Alagoz, Nese [3 ]
Tas, Mehmet [4 ]
机构
[1] Zonguldak Karaelmas Univ, Dept Ophthalmol, Zonguldak, Turkey
[2] Gaziosmanpasa Taksim Training & Res Hosp, Istanbul, Turkey
[3] Beyoglu Eye Training & Res Hosp, Istanbul, Turkey
[4] Malatya State Hosp, Dept Ophthalmol, Istanbul, Turkey
关键词
Corneal biomechanics; glaucoma; ocular response analyzer; pseudoexfoliation syndrome; pseudoexfoliative glaucoma; OCULAR RESPONSE ANALYZER; OPEN-ANGLE GLAUCOMA; EXFOLIATION SYNDROME; MICROSCOPY; THICKNESS;
D O I
10.3109/02713683.2014.930157
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the differences in corneal biomechanical properties between healthy subjects and patients with pseudoexfoliation syndrome (PEX) and pseudoexfoliative glaucoma (PEXG) using the ocular response analyzer (ORA). Materials and methods: One hundred eighteen eyes of 45 healthy, 43 PEX and 30 PEXG eyes were included in to the study. Corneal biomechanical parameters measurements were obtained using ORA. The main parameters assessed were corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated pressure measurement (IOPg) and corneal compensated intraocular pressure (IOPcc). Ultrasound pachymetry was used for measurement of central corneal thickness (CCT). Results: In healthy subjects, PEX and PEXG eyes' mean CH values were 10.3 +/- 1.4, 8.2 +/- 1.4 and 6.8 +/- 1.7 mmHg, respectively. The difference in mean CH between the PEXG and other two groups were statistically significant (p<0.001). Mean CRF values were 10.3 +/- 0.7, 7.9 +/- 1.6 and 7.9 +/- 1.9 mmHg, in healthy subjects PEX and PEXG, respectively. The difference in mean CRF between the PEX and PEXG was not statistically significant (p = 0.630), however the mean CRF was significantly higher in healthy subjects, compared to other two groups. Mean CCT were 546.3 +/- 28, 525.5 +/- 35 and 509 +/- 36 mu, in healthy subjects, PEX and PEXG, respectively. The differences on CCT were also significant among the three groups (p<0.001). Conclusion: In this study, the corneal biomechanical features of subjects with PEX were found to be changed as compared to healthy controls. In these patients; CH, CRF and CCT were decreased which was more obvious in patients with PEXG in comparison to PEX patients.
引用
收藏
页码:470 / 475
页数:6
相关论文
共 31 条
[1]   Corneal Hysteresis in Normal Subjects and in Patients with Primary Open-Angle Glaucoma and Pseudoexfoliation Glaucoma [J].
Ayala, Marcelo .
OPHTHALMIC RESEARCH, 2011, 46 (04) :187-191
[2]  
Bhat S., 2010, KOR J OPHTHALMOL, V22, P330
[3]   PROGRESSIVE CORNEAL ENDOTHELIAL-CELL CHANGES IN ANTERIOR SEGMENT DISEASE [J].
BROOKS, AMV ;
GRANT, G ;
ROBERTSON, IF ;
GILLIES, WE .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1987, 15 (01) :71-78
[4]   Ocular response analyzer to assess corneal biomechanical properties in exfoliation syndrome and exfoliative glaucoma [J].
Cankaya, Ali Bulent ;
Anayol, Alpaslan ;
Ozcelik, Dilek ;
Demirdogen, Elif ;
Yilmazbas, Pelin .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (02) :255-260
[5]   Assessment of true intraocular pressure: The gap between theory and practical data [J].
Chihara, Etsuo .
SURVEY OF OPHTHALMOLOGY, 2008, 53 (03) :203-218
[6]   Is diabetes mellitus a risk factor for open-angle glaucoma? The Rotterdam Study [J].
de Voogd, Simone ;
Ikram, M. Kamran ;
Wolfs, Roger C. W. ;
Jansonius, Nomdo M. ;
Witteman, Jacqueline C. M. ;
Hofman, Albert ;
de Jong, Paulus T. V. M. .
OPHTHALMOLOGY, 2006, 113 (10) :1827-1831
[7]   Assessment of myocardial ischaemia using tissue Doppler imaging in pseudoexfoliation syndrome [J].
Demir, N. ;
Ulus, T. ;
Yucel, O. E. ;
Kumral, E. T. ;
Singar, E. ;
Tanboga, H. I. .
EYE, 2011, 25 (09) :1177-1180
[8]   Ocular Pseudoexfoliation and Cardiovascular Disease: A National Cross-Section Comparison Study [J].
French, Dustin D. ;
Margo, Curtis E. ;
Harman, Lynn E. .
NORTH AMERICAN JOURNAL OF MEDICAL SCIENCES, 2012, 4 (10) :468-473
[9]   LONG-TERM FOLLOW-UP OF PSEUDOEXFOLIATION AND THE DEVELOPMENT OF ELEVATED INTRAOCULAR-PRESSURE [J].
HENRY, JC ;
KRUPIN, T ;
SCHMITT, M ;
LAUFFER, J ;
MILLER, E ;
EWING, MQ ;
SCHEIE, HG .
OPHTHALMOLOGY, 1987, 94 (05) :545-552
[10]  
HJORTDAL JO, 1995, ACTA OPHTHALMOL SCAN, V73, P12