Configuration optimization of an enhanced ejector heat exchanger based on an ejector refrigerator and a plate heat exchanger

被引:8
作者
Sun, Fangtian [1 ,2 ]
Chen, Xu [1 ]
Fu, Lin [2 ]
Zhang, Shigang [2 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Beijing 100044, Peoples R China
[2] Tsinghua Univ, Beijing 100084, Peoples R China
关键词
System configuration; Regulating characteristics; Thermodynamic performance; Industrial waste heat; District heating; Enhanced ejector heat exchanger; INDUSTRIAL-WASTE HEAT; SYSTEM; PERFORMANCE; COMPONENT; EFFICIENCIES; MODES;
D O I
10.1016/j.energy.2018.08.194
中图分类号
O414.1 [热力学];
学科分类号
摘要
Ejector heat exchanger has good performance in heat transfer, but its regulating characteristics are poor, and to improve its regulating characteristics, an enhanced ejector heat exchanger (EHE) with a pressure booster is presented. According to the difference in location of the pressure booster, the enhanced ejector heat exchangers are divided into two types. One is EHE-MF with its pressure booster located in the pipeline between outlet of ejector and refrigerant inlet of the condenser. The other is EHE-SF with its pressure booster located in the pipeline between secondary fluid inlet of ejector and refrigerant outlet of the evaporator. The two enhanced ejector heat exchangers have been analyzed from the perspective of thermodynamics. The results show that the location of pressure booster in the pipeline between outlet of ejector and refrigerant inlet of the condenser contributes to decreasing boosted pressure and power and increasing product exergy efficiency. The EHE-MF has higher thermodynamic performance, and its system configuration is optimal from the perspective of thermodynamics. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:408 / 417
页数:10
相关论文
共 31 条
[1]   A review on exergy analysis of vapor compression refrigeration system [J].
Ahamed, J. U. ;
Saidur, R. ;
Masjuki, H. H. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (03) :1593-1600
[2]   An Integrated Lumped Parameter-CFD approach for off-design ejector performance evaluation [J].
Besagni, Giorgio ;
Mereu, Riccardo ;
Chiesa, Paolo ;
Inzoli, Fabio .
ENERGY CONVERSION AND MANAGEMENT, 2015, 105 :697-715
[3]   Methods to estimate the industrial waste heat potential of regions - A categorization and literature review [J].
Brueckner, Sarah ;
Miro, Laia ;
Cabeza, Luisa F. ;
Pehnt, Martin ;
Laevemann, Eberhard .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 38 :164-171
[4]   A review on versatile ejector applications in refrigeration systems [J].
Chen, Jianyong ;
Jarall, Sad ;
Havtun, Hans ;
Palm, Bjorn .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 49 :67-90
[5]   Screening of working fluids for the ejector refrigeration system [J].
Chen, Jianyong ;
Hautun, Hans ;
Palm, Bjorn .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 47 :1-14
[6]   Parametric analysis of ejector working characteristics in the refrigeration system [J].
Chen, Jianyong ;
Havtun, Hans ;
Palm, Bjorn .
APPLIED THERMAL ENGINEERING, 2014, 69 (1-2) :130-142
[7]   Theoretical analysis of ejector refrigeration system performance under overall modes [J].
Chen, Weixiong ;
Shi, Chaoyin ;
Zhang, Shuangping ;
Chen, Huiqiang ;
Chong, Daotong ;
Yan, Junjie .
APPLIED ENERGY, 2017, 185 :2074-2084
[8]   Recent developments in ejector refrigeration technologies [J].
Chen, Xiangjie ;
Omer, Siddig ;
Worall, Mark ;
Riffat, Saffa .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 19 :629-651
[9]   Innovative planning and evaluation system for district heating using waste heat considering spatial configuration: A case in Fukushima, Japan [J].
Dou, Yi ;
Togawa, Takuya ;
Dong, Liang ;
Fujii, Minoru ;
Ohnishi, Satoshi ;
Tanikawa, Hiroki ;
Fujita, Tsuyoshi .
RESOURCES CONSERVATION AND RECYCLING, 2018, 128 :406-416
[10]   Key issues and solutions in a district heating system using low-grade industrial waste heat [J].
Fang, Hao ;
Xia, Jianjun ;
Jiang, Yi .
ENERGY, 2015, 86 :589-602