Characterizing a proton beam scanning system for Monte Carlo dose calculation in patients

被引:50
|
作者
Grassberger, C. [1 ,2 ]
Lomax, Anthony [2 ]
Paganetti, H. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
关键词
active scanning proton therapy; Monte Carlo simulation; patient dose calculation; RANGE UNCERTAINTIES; THERAPY; TOPAS;
D O I
10.1088/0031-9155/60/2/633
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The presented work has two goals. First, to demonstrate the feasibility of accurately characterizing a proton radiation field at treatment head exit for Monte Carlo dose calculation of active scanning patient treatments. Second, to show that this characterization can be done based on measured depth dose curves and spot size alone, without consideration of the exact treatment head delivery system. This is demonstrated through calibration of a Monte Carlo code to the specific beam lines of two institutions, Massachusetts General Hospital (MGH) and Paul Scherrer Institute (PSI). Comparison of simulations modeling the full treatment head at MGH to ones employing a parameterized phase space of protons at treatment head exit reveals the adequacy of the method for patient simulations. The secondary particle production in the treatment head is typically below 0.2% of primary fluence, except for low-energy electrons (<0.6 MeV for 230 MeV protons), whose contribution to skin dose is negligible. However, there is significant difference between the two methods in the low-dose penumbra, making full treatment head simulations necessary to study out-of-field effects such as secondary cancer induction. To calibrate the Monte Carlo code to measurements in a water phantom, we use an analytical Bragg peak model to extract the range-dependent energy spread at the two institutions, as this quantity is usually not available through measurements. Comparison of the measured with the simulated depth dose curves demonstrates agreement within 0.5 mm over the entire energy range. Subsequently, we simulate three patient treatments with varying anatomical complexity (liver, head and neck and lung) to give an example how this approach can be employed to investigate site-specific discrepancies between treatment planning system and Monte Carlo simulations.
引用
收藏
页码:633 / 645
页数:13
相关论文
共 50 条
  • [41] Unsupervised classification of tissues composition for Monte Carlo dose calculation
    Lalonde, Arthur
    Remy, Charlotte
    Simard, Mikael
    Bouchard, Hugo
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (15)
  • [42] Developing a Monte Carlo model for MEVION S250i with HYPERSCAN and Adaptive Aperture™ pencil beam scanning proton therapy system
    Chiang, Bing-Hao
    Bunker, Austin
    Jin, Hosang
    Ahmad, Salahuddin
    Chen, Yong
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 20 (03) : 279 - 286
  • [43] A Python']Python package for fast GPU-based proton pencil beam dose calculation
    Bhattacharya, Mahasweta
    Reamy, Calin
    Li, Heng
    Lee, Junghoon
    Hrinivich, William T.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025,
  • [44] Effect of Scanning Beam for Superficial Dose in Proton Therapy
    Moskvin, Vadim P.
    Estabrook, Neil C.
    Cheng, Chee-Wai
    Das, Indra J.
    Johnstone, Peter A. S.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (05) : 643 - 652
  • [45] Simple beam models for Monte Carlo photon beam dose calculations in radiotherapy
    Fix, MK
    Keller, H
    Rüegsegger, P
    Born, EJ
    MEDICAL PHYSICS, 2000, 27 (12) : 2739 - 2747
  • [46] Feasibility of on-line multiple scanning proton beam range verification with PET imaging: Monte Carlo simulation studies
    Zhong, Yuncheng
    Lu, Weiguo
    Jia, Xun
    Shao, Yiping
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [47] Dosimetric evaluation of a commercial proton spot scanning Monte-Carlo dose algorithm: comparisons against measurements and simulations
    Saini, Jatinder
    Maes, Dominic
    Egan, Alexander
    Bowen, Stephen R.
    St James, Sara
    Janson, Martin
    Wong, Tony
    Bloch, Charles
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (19) : 7659 - 7681
  • [48] GATE as a GEANT4-based Monte Carlo platform for the evaluation of proton pencil beam scanning treatment plans
    Grevillot, L.
    Bertrand, D.
    Dessy, F.
    Freud, N.
    Sarrut, D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (13) : 4223 - 4244
  • [49] Validating a double Gaussian source model for small proton fields in a commercial Monte-Carlo dose calculation engine
    Kugel, Fabian
    Wulff, Jorg
    Baeumer, Christian
    Janson, Martin
    Kretschmer, Jana
    Brodbek, Leonie
    Behrends, Carina
    Verbeek, Nico
    Looe, Hui Khee
    Poppe, Bjorn
    Timmermann, Beate
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2023, 33 (04): : 529 - 541
  • [50] Technical Note: An approach to building a Monte Carlo simulation model for a double scattering proton beam system
    Yuan, Jiankui
    Ellis, Rodney
    Machtay, Mitchell
    MEDICAL PHYSICS, 2018, 45 (06) : 2660 - 2666