Characterizing a proton beam scanning system for Monte Carlo dose calculation in patients

被引:50
|
作者
Grassberger, C. [1 ,2 ]
Lomax, Anthony [2 ]
Paganetti, H. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
关键词
active scanning proton therapy; Monte Carlo simulation; patient dose calculation; RANGE UNCERTAINTIES; THERAPY; TOPAS;
D O I
10.1088/0031-9155/60/2/633
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The presented work has two goals. First, to demonstrate the feasibility of accurately characterizing a proton radiation field at treatment head exit for Monte Carlo dose calculation of active scanning patient treatments. Second, to show that this characterization can be done based on measured depth dose curves and spot size alone, without consideration of the exact treatment head delivery system. This is demonstrated through calibration of a Monte Carlo code to the specific beam lines of two institutions, Massachusetts General Hospital (MGH) and Paul Scherrer Institute (PSI). Comparison of simulations modeling the full treatment head at MGH to ones employing a parameterized phase space of protons at treatment head exit reveals the adequacy of the method for patient simulations. The secondary particle production in the treatment head is typically below 0.2% of primary fluence, except for low-energy electrons (<0.6 MeV for 230 MeV protons), whose contribution to skin dose is negligible. However, there is significant difference between the two methods in the low-dose penumbra, making full treatment head simulations necessary to study out-of-field effects such as secondary cancer induction. To calibrate the Monte Carlo code to measurements in a water phantom, we use an analytical Bragg peak model to extract the range-dependent energy spread at the two institutions, as this quantity is usually not available through measurements. Comparison of the measured with the simulated depth dose curves demonstrates agreement within 0.5 mm over the entire energy range. Subsequently, we simulate three patient treatments with varying anatomical complexity (liver, head and neck and lung) to give an example how this approach can be employed to investigate site-specific discrepancies between treatment planning system and Monte Carlo simulations.
引用
收藏
页码:633 / 645
页数:13
相关论文
共 50 条
  • [21] NRG Oncology Survey of Monte Carlo Dose Calculation Use in US Proton Therapy Centers
    Lin, Liyong
    Taylor, Paige A.
    Shen, Jiajian
    Saini, Jatinder
    Kang, Minglei
    Simone, Charles B.
    Bradley, Jeffrey D.
    Li, Zuofeng
    Xiao, Ying
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2021, 8 (02) : 73 - 81
  • [22] The effects of a transverse magnetic field on the dose enhancement of nanoparticles in a proton beam: a Monte Carlo simulation
    Parishan, Mohammadreza
    Faghihi, Reza
    Kadoya, Noriyuki
    Jingu, Keiichi
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (08)
  • [23] A sector-integration method for dose/MU calculation in a uniform scanning proton beam
    Zhao, Qingya
    Wu, Huanmei
    Wolanski, Mark
    Pack, Daniel
    Johnstone, Peter A. S.
    Das, Indra J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (03) : N87 - N95
  • [24] Validation and application of a fast Monte Carlo algorithm for assessing the clinical impact of approximations in analytical dose calculations for pencil beam scanning proton therapy
    Huang, Sheng
    Souris, Kevin
    Li, Siyang
    Kang, Minglei
    Montero, Ana Maria Barragan
    Janssens, Guillaume
    Lin, Alexander
    Garver, Elizabeth
    Ainsley, Christopher
    Taylor, Paige
    Xiao, Ying
    Lin, Liyong
    MEDICAL PHYSICS, 2018, 45 (12) : 5631 - 5642
  • [25] Development and validation of the Dynamic Collimation Monte Carlo simulation package for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Yu, Jen
    Rana, Suresh
    Gutierrez, Alonso N.
    Hill, Patrick M.
    MEDICAL PHYSICS, 2021, 48 (06) : 3172 - 3185
  • [26] Technical Note: Defining cyclotron-based clinical scanning proton machines in a FLUKA Monte Carlo system
    Fiorini, Francesca
    Schreuder, Niek
    Van den Heuvel, Frank
    MEDICAL PHYSICS, 2018, 45 (02) : 963 - 970
  • [27] Determination of surface dose in pencil beam scanning proton therapy
    Kern, A.
    Baeumer, C.
    Kroeninger, K.
    Mertens, L.
    Timmermann, B.
    Walbersloh, J.
    Wulff, J.
    MEDICAL PHYSICS, 2020, 47 (05) : 2277 - 2288
  • [28] Proton minibeam (pMBRT) radiation therapy: experimental validation of Monte Carlo dose calculation in the RayStation TPS
    Lin, Yuting
    Traneus, Erik
    Wang, Aoxiang
    Li, Wangyao
    Gao, Hao
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (04)
  • [29] Monte Carlo simulation of single beam dose profile
    LIU Xiaowei
    WEN Guanghao
    LI Mianfeng(Zhongshan University
    NuclearScienceandTechniques, 1999, (02) : 87 - 90
  • [30] A Monte Carlo study for the calculation of the average linear energy transfer (LET) distributions for a clinical proton beam line and a radiobiological carbon ion beam line
    Romano, F.
    Cirrone, G. A. P.
    Cuttone, G.
    Di Rosa, F.
    Mazzaglia, S. E.
    Petrovic, I.
    Fira, A. Ristic
    Varisano, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (12) : 2863 - 2882