A label-free multiplex electrochemical biosensor for the detection of three breast cancer biomarker proteins employing dye/metal ion-loaded and antibody-conjugated polyethyleneimine-gold nanoparticles

被引:59
作者
Kuntamung, Kulrisa [1 ,2 ]
Jakmunee, Jaroon [1 ,3 ,4 ,5 ]
Ounnunkad, Kontad [1 ,3 ,4 ,5 ]
机构
[1] Chiang Mai Univ, Fac Sci, Dept Chem, Chiang Mai 50200, Thailand
[2] Chiang Mai Univ, Grad Sch, Chiang Mai 50200, Thailand
[3] Chiang Mai Univ, Fac Sci, Ctr Excellence Innovat Chem, Chiang Mai 50200, Thailand
[4] Chiang Mai Univ, Res Ctr Chem Dev Hlth Promoting Prod Northern Res, Chiang Mai 50200, Thailand
[5] Chiang Mai Univ, Ctr Excellence Mat Sci & Technol, Chiang Mai 50200, Thailand
关键词
TUMOR-MARKERS; VOLTAMMETRIC IMMUNOSENSOR; IMMUNOASSAY; PLATFORM;
D O I
10.1039/d1tb00940k
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
A new electrochemical immunosensor is developed for the label-free simultaneous detection of mucin1 (MUC1), cancer antigen 15-3 (CA15-3), and human epidermal growth factor receptor 2 (HER2) early breast cancer biomarkers. The biosensor is simply designed using the deposition of three different systems of redox species-antibody-conjugated polyethylenimine coated-gold nanoparticles (PEI-AuNPs), for the first time. The screen-printed carbon electrode (SPCE) comprising a three-working electrode array is modified with the conjugated PEI-AuNPs. Multiplex sensing is performed by utilizing the distinguishable electrochemical responses of the redox-active species; anthraquinone-2-carboxylic acid (AQ), thionine chloride (TH), and AgNO3 (Ag+) on the PEI-AuNPs conjugates for the detection of MUC1, CA15-3, and HER2, respectively. The single-run determination of the biomarkers by the proposed immunosensor is carried out by measuring the decrease (%) in the oxidation peak currents due to the formation of three kinds of antibody-antigen complexes. The decreased currents are logarithmically proportional to the antigen concentrations in the ranges of 0.10-100 U mL(-1) CA15-3 and 0.10-100 ng mL(-1) MUC1 and HER2 with detection limits of 0.21 U mL(-1), 0.53 ng mL(-1) and 0.50 ng mL(-1), respectively, which are significantly lower than the clinically relevant cut-off levels. The sensor reveals high selectivity and satisfactory reproducibility. After storing for two weeks, the sensor retains the responses with ca. 90% of the initial currents. The immunosensor is successfully applied to detect three tumor markers in human serum and can provide a new technological platform for the development of low-cost, highly stable, sensitive, selective, and point-of-care (POC) diagnosis.
引用
收藏
页码:6576 / 6585
页数:11
相关论文
共 41 条
[1]   Are preoperative serum CA15-3 levels different in breast cancer subgroups? [J].
Araz, Murat ;
Beypinar, Ismail ;
Kazan, Sinan ;
Inci, Fatih ;
Celiker, Mesut ;
Uysal, Mukremin .
CURRENT PROBLEMS IN CANCER, 2019, 43 (02) :115-122
[2]   Role of gold nanoparticles in advanced biomedical applications [J].
Bansal, Suneev Anil ;
Kumar, Vanish ;
Karimi, Javad ;
Singh, Amrinder Pal ;
Kumar, Suresh .
NANOSCALE ADVANCES, 2020, 2 (09) :3764-3787
[3]   Multiplexed electrochemical immunoassay of biomarkers using chitosan nanocomposites [J].
Chen, Xia ;
Ma, Zhanfang .
BIOSENSORS & BIOELECTRONICS, 2014, 55 :343-349
[4]   Electrochemical immunosensor for simultaneous detection of multiplex cancer biomarkers based on graphene nanocomposites [J].
Chen, Xia ;
Jia, Xinle ;
Han, Jingman ;
Ma, Jie ;
Ma, Zhanfang .
BIOSENSORS & BIOELECTRONICS, 2013, 50 :356-361
[5]   Ultrasensitive electrochemical immunosensors for multiplexed determination using mesoporous platinum nanoparticles as nonenzymatic labels [J].
Cui, Zhentao ;
Wu, Dan ;
Zhang, Yong ;
Ma, Hongmin ;
Li, He ;
Du, Bin ;
Wei, Qin ;
Ju, Huangxian .
ANALYTICA CHIMICA ACTA, 2014, 807 :44-50
[6]   An electrochemical immunosensor for simultaneous point-of-care cancer markers based on the host-guest inclusion of β-cyclodextrin-graphene oxide [J].
Feng, Taotao ;
Qiao, Xiuwen ;
Wang, Haining ;
Sun, Zhao ;
Qi, Yu ;
Hong, Chenglin .
JOURNAL OF MATERIALS CHEMISTRY B, 2016, 4 (05) :990-996
[7]   Nanostructures for nonlabeled and labeled electrochemical immunosensors: Simultaneous electrochemical detection of cancer markers: A review [J].
Filik, Hayati ;
Avan, A. Aslihan .
TALANTA, 2019, 205
[8]   A graphene oxide-based fluorescent aptasensor for the turn-on detection of epithelial tumor marker mucin 1 [J].
He, Yue ;
Lin, Yi ;
Tang, Hongwu ;
Pang, Daiwen .
NANOSCALE, 2012, 4 (06) :2054-2059
[9]   Novel electrochemical aptamer biosensor based on an enzyme-gold nanoparticle dual label for the ultrasensitive detection of epithelial tumour marker MUC1 [J].
Hu, Rong ;
Wen, Wei ;
Wang, Qingling ;
Xiong, Huayu ;
Zhang, Xiuhua ;
Gu, Haoshuang ;
Wang, Shengfu .
BIOSENSORS & BIOELECTRONICS, 2014, 53 :384-389
[10]   Simple and effective label-free electrochemical immunoassay for carbohydrate antigen 19-9 based on polythionine-Au composites as enhanced sensing signals for detecting different clinical samples [J].
Huang, Zhengjun ;
Jiang, Zhouqian ;
Zhao, Chengfei ;
Han, Wendi ;
Lin, Liqing ;
Liu, Ailin ;
Weng, Shaohuang ;
Lin, Xinhua .
INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 :3049-3058