Digital radiography: optimization of image quality and dose using multi-frequency software

被引:20
|
作者
Precht, H. [1 ]
Gerke, O. [2 ,3 ]
Rosendahl, K. [4 ,5 ]
Tingberg, A. [6 ]
Waaler, D. [7 ]
机构
[1] Univ Coll Lillebelt, Conrad Res Ctr, DK-5220 Odense SO, Denmark
[2] Odense Univ Hosp, Dept Nucl Med, DK-5000 Odense C, Denmark
[3] Univ So Denmark, Res Unit Hlth Econ, DK-5000 Odense C, Denmark
[4] Haukeland Hosp, Sect Pediat Radiol, N-5021 Bergen, Norway
[5] Univ Bergen, Inst Surg Sci, Bergen, Norway
[6] Lund Univ, Skane Univ Hosp, Dept Clin Sci, SE-20502 Malmo, Sweden
[7] Gjovik Univ Coll, N-2815 Gjovik, Norway
关键词
Digital radiography; Software optimization; Multi-frequency processing; Dose reduction; CHEST;
D O I
10.1007/s00247-012-2385-3
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
New developments in processing of digital radiographs (DR), including multi-frequency processing (MFP), allow optimization of image quality and radiation dose. This is particularly promising in children as they are believed to be more sensitive to ionizing radiation than adults. To examine whether the use of MFP software reduces the radiation dose without compromising quality at DR of the femur in 5-year-old-equivalent anthropomorphic and technical phantoms. A total of 110 images of an anthropomorphic phantom were imaged on a DR system (Canon DR with CXDI-50 C detector and MLT[S] software) and analyzed by three pediatric radiologists using Visual Grading Analysis. In addition, 3,500 images taken of a technical contrast-detail phantom (CDRAD 2.0) provide an objective image-quality assessment. Optimal image-quality was maintained at a dose reduction of 61% with MLT(S) optimized images. Even for images of diagnostic quality, MLT(S) provided a dose reduction of 88% as compared to the reference image. Software impact on image quality was found significant for dose (mAs), dynamic range dark region and frequency band. By optimizing image processing parameters, a significant dose reduction is possible without significant loss of image quality.
引用
收藏
页码:1112 / 1118
页数:7
相关论文
共 50 条
  • [41] Large dose reduction by optimization of multifrequency processing software in digital radiography at follow-up examinations of the pediatric femur
    Helle Precht
    Oke Gerke
    Karen Rosendahl
    Anders Tingberg
    Dag Waaler
    Pediatric Radiology, 2014, 44 : 239 - 240
  • [42] Digital radiography of the skeleton using a large-area detector based on amorphous silicon technology:: Image quality and potential for dose reduction in comparison with screen-film radiography
    Völk, M
    Strotzer, M
    Holzknecht, N
    Manke, C
    Lenhart, M
    Gmeinwieser, J
    Link, J
    Reiser, M
    Feuerbach, S
    CLINICAL RADIOLOGY, 2000, 55 (08) : 615 - 621
  • [43] Automatic image quality evaluation in digital radiography using for-processing and for-presentation images
    Tsalafoutas, Ioannis A.
    Alkhazzam, Shady
    Tsapaki, Virginia
    Kharita, Mohammed Hassan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (04):
  • [44] Automatic image quality evaluation in digital radiography using a modified version of the IAEA radiography phantom allowing multiple detection tasks
    Tsalafoutas, Ioannis A.
    Alkhazzam, Shady
    Tsapaki, Virginia
    Kharita, Mohammed Hassan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025, 26 (02):
  • [45] Management of pediatric radiation dose using Canon digital radiography
    M. Arreola
    L. Rill
    Pediatric Radiology, 2004, 34 : S221 - S226
  • [46] IMAGE QUALITY OF A DIGITAL CHEST RADIOGRAPHY SYSTEM BASED ON A SELENIUM DETECTOR
    NEITZEL, U
    MAACK, I
    GUNTHERKOHFAHL, S
    MEDICAL PHYSICS, 1994, 21 (04) : 509 - 516
  • [47] Subjective image quality in digital panoramic radiography in relation to patient exposure
    Scheifele, C
    Hadjizadeh, H
    Thole, U
    Wree, A
    Hopfenmüller, W
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 1183 - 1183
  • [48] Management of pediatric radiation dose using Philips digital radiography
    U. Neitzel
    Pediatric Radiology, 2004, 34 : S227 - S233
  • [49] Image quality of supine chest radiographs: intra-individual comparison of computed radiography and low-dose linear-slit digital radiography
    Szucs-Farkas, Zsolt
    Vock, Peter
    EUROPEAN RADIOLOGY, 2009, 19 (09) : 2156 - 2162
  • [50] Management of pediatric radiation dose using Canon digital radiography
    Arreola, M
    Rill, L
    PEDIATRIC RADIOLOGY, 2004, 34 (Suppl 3) : S221 - S226