Digital radiography: optimization of image quality and dose using multi-frequency software

被引:20
|
作者
Precht, H. [1 ]
Gerke, O. [2 ,3 ]
Rosendahl, K. [4 ,5 ]
Tingberg, A. [6 ]
Waaler, D. [7 ]
机构
[1] Univ Coll Lillebelt, Conrad Res Ctr, DK-5220 Odense SO, Denmark
[2] Odense Univ Hosp, Dept Nucl Med, DK-5000 Odense C, Denmark
[3] Univ So Denmark, Res Unit Hlth Econ, DK-5000 Odense C, Denmark
[4] Haukeland Hosp, Sect Pediat Radiol, N-5021 Bergen, Norway
[5] Univ Bergen, Inst Surg Sci, Bergen, Norway
[6] Lund Univ, Skane Univ Hosp, Dept Clin Sci, SE-20502 Malmo, Sweden
[7] Gjovik Univ Coll, N-2815 Gjovik, Norway
关键词
Digital radiography; Software optimization; Multi-frequency processing; Dose reduction; CHEST;
D O I
10.1007/s00247-012-2385-3
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
New developments in processing of digital radiographs (DR), including multi-frequency processing (MFP), allow optimization of image quality and radiation dose. This is particularly promising in children as they are believed to be more sensitive to ionizing radiation than adults. To examine whether the use of MFP software reduces the radiation dose without compromising quality at DR of the femur in 5-year-old-equivalent anthropomorphic and technical phantoms. A total of 110 images of an anthropomorphic phantom were imaged on a DR system (Canon DR with CXDI-50 C detector and MLT[S] software) and analyzed by three pediatric radiologists using Visual Grading Analysis. In addition, 3,500 images taken of a technical contrast-detail phantom (CDRAD 2.0) provide an objective image-quality assessment. Optimal image-quality was maintained at a dose reduction of 61% with MLT(S) optimized images. Even for images of diagnostic quality, MLT(S) provided a dose reduction of 88% as compared to the reference image. Software impact on image quality was found significant for dose (mAs), dynamic range dark region and frequency band. By optimizing image processing parameters, a significant dose reduction is possible without significant loss of image quality.
引用
收藏
页码:1112 / 1118
页数:7
相关论文
共 50 条
  • [1] Digital radiography: optimization of image quality and dose using multi-frequency software
    H. Precht
    O. Gerke
    K. Rosendahl
    A. Tingberg
    D. Waaler
    Pediatric Radiology, 2012, 42 : 1112 - 1118
  • [2] Optimization of dose and image quality for computed radiography and digital radiography
    Aldrich, JE
    Duran, E
    Dunlop, P
    Mayo, JR
    JOURNAL OF DIGITAL IMAGING, 2006, 19 (02) : 126 - 131
  • [3] Optimization of Dose and Image Quality for Computed Radiography and Digital Radiography
    John E. Aldrich
    Emerenciana Duran
    Pat Dunlop
    John R. Mayo
    Journal of Digital Imaging, 2006, 19 : 126 - 131
  • [4] Dose Optimization and Image Quality in Digital Radiography: A Review Article
    Barai, Juhi
    Tivaskar, Suhas
    Sable, Apeksha
    Luharia, Anurag
    JOURNAL OF PHARMACEUTICAL NEGATIVE RESULTS, 2022, 13 (03) : 1076 - 1080
  • [5] Optimization of dose and image quality in pediatrics chest digital radiography
    Deevband, Mohammad Reza
    Rahmani, Fereshteh
    Bardar, Meisam Ebrahimi
    Ghorbani, Mahdi
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2021, 52 (03) : 443 - 449
  • [6] Optimization of image quality and patient dose in radiographs of paediatric extremities using direct digital radiography
    Jones, A.
    Ansell, C.
    Jerrom, C.
    Honey, I. D.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1050)
  • [7] Digital radiography image quality evaluation using various phantoms and software
    Tsalafoutas, Ioannis A.
    AlKhazzam, Shady
    Tsapaki, Virginia
    AlNaemi, Huda
    Kharita, Mohammed Hassan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):
  • [8] Image Quality Optimization vs. Patient Dose in Digital Thoracic Radiography
    Perez-Diaz, M.
    Ruiz-Gonzalez, Y.
    Machin-Linares, L.
    Ely-Andrade, M.
    Barros-Saito, J. C.
    Khoury, H. J.
    Ventosa-Almeida, J. C.
    VI LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2014), 2014, 49 : 353 - 356
  • [9] Image quality and exposure dose in digital projection radiography
    Busch, HP
    Busch, S
    Decker, C
    Schilz, C
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (01): : 32 - 37
  • [10] New image quality and dose reduction technique for pediatric digital radiography
    Feghali, Joelle A.
    Chambers, Greg
    Delepierre, Julie
    Chapeliere, Sophie
    Mannes, Ines
    Adamsbaum, Catherine
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (7-8) : 463 - 470