Non-invasive intraocular pressure monitoring with a contact lens engineered with a nanostructured polymeric sensing film

被引:47
|
作者
Laukhin, Vladimir [1 ,2 ]
Sanchez, Irene [3 ,4 ]
Moya, Ana [4 ,5 ]
Laukhina, Elena [1 ,4 ]
Martin, Raul [3 ,4 ,6 ]
Ussa, Fernando [3 ]
Rovira, Concepcio [1 ,4 ]
Guimera, Anton [4 ,5 ]
Villa, Rosa [4 ,5 ]
Aguilo, Jordi [4 ,5 ]
Pastor, Jose-Carlos [3 ]
Veciana, Jaume [1 ,4 ]
机构
[1] CSIC, Inst Ciencia Mat Barcelona, E-08193 Barcelona, Spain
[2] ICREA, Catalunya, Spain
[3] Univ Valladolid, IOBA Eye Inst, Valladolid, Spain
[4] Networking Res Ctr Bioengn Biomat & Nanomed CIBER, Zaragoza, Spain
[5] CSIC, Inst Microelect Barcelona IMB CNM, E-08193 Barcelona, Spain
[6] Univ Valladolid, Sch Optometry, Dept Phys TAO, Valladolid, Spain
关键词
Glaucoma; Pressure sensor; Nanostructured polymer composite; Contact lens; Intraocular pressure; In vitro experiments; OPEN-ANGLE GLAUCOMA; CORNEAL CURVATURE;
D O I
10.1016/j.sna.2011.05.021
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new prototype of contact lens sensor (CLS) for monitoring the intraocular pressure (IOP) variations in a non-invasive way has been developed. The CLS has as a key element a thin film, comprised of a new all-organic flexible highly piezo-resistive sensor, that is glued to the central hole of a doughnut-shaped hard contact lens. A few CLSs were fabricated and tested with an eye phantom and with enucleated pig eyes by means of applying pressure with a low pressure transducer and recording the electrical changes in the sensor with a portable recorder. The developed CLSs are biocompatible permitting to transmit the changes in cornea curvature induced by the IOP variations, directly to the flexible conducting polymeric sensor embedded in the CL The electrical response of the CLS to pressure changes reveals a high linearity as well as a good reproducibility having the proper sensitivity to perform continuous monitoring of LOP. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:36 / 43
页数:8
相关论文
共 50 条
  • [31] High-sensitive microfluidic contact lens sensor for intraocular pressure visualized monitoring
    Yuan, Miao
    Liu, Zhiduo
    Wu, Xiaoting
    Gou, Haoyang
    Zhang, Yugui
    Ning, Xin
    Li, Weijun
    Yao, Zhaohui
    Wang, Yijun
    Pei, Weihua
    Chen, Hongda
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 354
  • [32] Non-Invasive Intracranial Pressure Monitoring and Its Applicability in Spaceflight
    Felix, Hugo
    Oliveira, Edson Santos
    AEROSPACE MEDICINE AND HUMAN PERFORMANCE, 2022, 93 (06) : 517 - 531
  • [33] The effects of non-invasive mechanic ventilator modes on intraocular pressure in COPD patients with hypercapnic respiratory failure
    Aytekin, Fuat
    Gulhan, Pinar Yildiz
    Teberik, Kuddusi
    Balbay, Ege Gulec
    Iritas, Ilter
    Ercelik, Merve
    Elverisli, Mehmet Fatih
    Balbay, Oner Abidin
    CLINICAL RESPIRATORY JOURNAL, 2020, 14 (02): : 165 - 172
  • [34] Smart Contact Lenses-A Step towards Non-Invasive Continuous Eye Health Monitoring
    Kazanskiy, Nikolay L.
    Khonina, Svetlana N.
    Butt, Muhammad A.
    BIOSENSORS-BASEL, 2023, 13 (10):
  • [35] Efficacy of a Contact Lens Sensor for Monitoring 24-H Intraocular Pressure Related Patterns
    Mansouri, Kaweh
    Weinreb, Robert N.
    Liu, John H. K.
    PLOS ONE, 2015, 10 (05):
  • [36] Correlation between corneal and contact lens deformation with changes in intraocular pressure for wearable monitoring systems
    Campigotto, Angelica
    Campbell, Robert J.
    Lai, Yongjun
    EYE, 2023, 37 (10) : 2055 - 2060
  • [37] Continuous 24 h monitoring of changes in intraocular pressure with the wireless contact lens sensor Triggerfish™. First results in patients
    Faschinger, C.
    Mossboeck, G.
    OPHTHALMOLOGE, 2010, 107 (10): : 918 - 922
  • [38] Fish Fin-Derived Non-Invasive Flexible Bioinspired Contact Lens for Continuous Ophthalmic Drug Delivery
    Li, Xu
    Li, Hui
    Wang, Zihao
    Wang, Xianda
    Zhang, Jinlong
    Bin, Fengjiao
    Chen, Wei
    Li, Hongyang
    Huo, Dongmei
    Xiao, Dengbao
    ADVANCED SCIENCE, 2025, 12 (06)
  • [39] 24-Hour Contact Lens Sensor Monitoring of Intraocular Pressure-Related Profiles in Normal-Tension Glaucoma and Rates of Disease Progression
    Hoban, Katie
    Peden, Robert
    Megaw, Roly
    Halpin, Patricia
    Tatham, Andrew J.
    OPHTHALMIC RESEARCH, 2017, 57 (04) : 208 - 215
  • [40] Continuous intraocular pressure monitoring in patients with obstructive sleep apnea syndrome using a contact lens sensor
    Carnero, Elena
    Bragard, Jean
    Urrestarazu, Elena
    Rivas, Estefania
    Polo, Vicente
    Manuel Larrosa, Jose
    Anton, Vanesa
    Pelaez, Antonio
    Moreno-Montanes, Javier
    PLOS ONE, 2020, 15 (03):