Mid-infrared and Raman spectrometry for quality control of pesticide formulations

被引:54
|
作者
Armenta, S [1 ]
Quintás, G [1 ]
Garrigues, S [1 ]
de la Guardia, M [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Burjassot, Spain
关键词
ATR; attenuated total reflection; FIA; flow-injection analysis; formulation; Fourier transform infrared; Fourier transform Raman; FTIR; FT-Raman; pesticide; vibrational spectrometry;
D O I
10.1016/j.trac.2005.03.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This article deals with recent developments in the use of vibrational spectrometry for the quantitative analysis of active components in commercial pesticide formulations. We review the techniques, such as Fourier transform infrared (FTIR) and FT-Raman spectrometries, and measurement modes, such as stopped flow or flow injection. FTIR is being used increasingly in the determination of pesticides in agrochemical products because of its relatively short analysis time. However, FT-Raman spectrometry provides direct analysis of solid and aqueous samples. It is therefore clear that these techniques enable fast, non-destructive, precise and accurate measurements, so vibrational spectrometry appears to be a promising tool for on-line process monitoring and analysis in the agrochemical industry. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:772 / 781
页数:10
相关论文
共 50 条
  • [41] Plasmonics in the mid-infrared
    Ross Stanley
    Nature Photonics, 2012, 6 : 409 - 411
  • [42] INFRARED ANALYSIS OF PESTICIDE FORMULATIONS
    GOZA, SW
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1972, 55 (05): : 913 - +
  • [43] Mid-infrared optical spin injection and coherent control
    Fettu, G.
    Sipe, J. E.
    Moutanabbir, O.
    PHYSICAL REVIEW B, 2023, 107 (16)
  • [44] Mid-infrared soliton and Raman frequency comb generation in silicon microrings
    Hansson, Tobias
    Modotto, Daniele
    Wabnitz, Stefan
    OPTICS LETTERS, 2014, 39 (23) : 6747 - 6750
  • [45] Theoretical analysis and design of mid-infrared ZBLAN fiber Raman laser
    Li, Jianfeng
    Ou, Zhonghua
    Dai, Zhiyong
    Peng, Zengshou
    Zhang, Lixun
    Liu, Yongzhi
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2011, 40 (08): : 1432 - 1437
  • [46] Detecting adulterants in milk with lower cost mid-infrared and Raman spectroscopy
    Lee, Changwon
    Wang, Wenbo
    Wilson, Benjamin K.
    Connett, Marie
    Keller, Matthew D.
    OPTICS AND BIOPHOTONICS IN LOW-RESOURCE SETTINGS IV, 2018, 10485
  • [47] Shining in the mid-infrared
    Rachel Won
    Nature Photonics, 2011, 5 (8) : 457 - 458
  • [48] Mid-Infrared Lasers
    Carrig, Timothy J.
    Schober, Andrew M.
    IEEE PHOTONICS JOURNAL, 2010, 2 (02): : 207 - 212
  • [49] Progress on Mid-Infrared Raman Lasers Based on Special Glass Fibers
    Jia Zhixu
    Guo Xiaohui
    Jia Yadong
    Qin Weiping
    Qin Guanshi
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2022, 49 (01):
  • [50] Nonlinear absorption in silicon and the prospects of mid-infrared silicon Raman lasers
    Raghunathan, V
    Shori, R
    Stafsudd, OM
    Jalali, B
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2006, 203 (05): : R38 - R40