Correlation in Retinal Nerve Fiber Layer Thickness between Two OCT Units

被引:7
作者
Chen, Hsin-Yi [1 ,2 ]
Chang, Yue-Cune [3 ]
Lane, Hsien-Yuan [1 ,4 ]
机构
[1] China Med Univ, Grad Inst Clin Med Sci, Taichung, Taiwan
[2] China Med Univ Hosp, Dept Ophthalmol, Glaucoma Serv, Taichung 404, Taiwan
[3] Tamkang Univ, Dept Math, Taipei, Taiwan
[4] China Med Univ Hosp, Dept Psychiat, Taichung 404, Taiwan
关键词
correlation; Stratus OCT; Cirrus OCT; Taiwan Chinese population; OPTICAL COHERENCE TOMOGRAPHY; SPECTRAL-DOMAIN; GLAUCOMA-DETECTION; TIME-DOMAIN; CIRRUS HD; DIAGNOSIS; CLASSIFIERS; VARIABILITY;
D O I
10.1097/OPX.0b013e31822f4b82
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. It is expected that spectral-domain optical coherence tomography (SD-OCT) will replace time-domain (TD)-OCT in the near future. In this study, we applied a robust set of statistical analyses to evaluate the correlation between retinal nerve fiber layer (RNFL) thickness measurements obtained by SD-OCT and those obtained by TD-OCT in a Chinese population with different stages of glaucoma. Methods. A total of 40 patients with primary open-angle glaucoma, 31 with primary angle-closure glaucoma (PACG), 31 with suspected glaucoma (GS), 25 with ocular hypertension (OH), and 52 normal subjects were enrolled in this prospective, cross-sectional study. Eyes of all participants were imaged by a single trained operator using the Stratus TD-OCT (fast RNFL scan mode) system and the Cirrus SD-OCT (optic disc cube mode) system during the same visit. The correlations between RNFL thickness measurements obtained from the two OCT instruments were assessed using Pearson correlation analysis and generalized estimating equation (GEE), mixed effect, linear regression models, after adjusting for the effect of individual variation. Results. There was good correlation in RNFL thickness parameters between the two OCT devices, particularly in average RNFL thickness (Pearson Correlation, 0.8798 vs. GEE mixed model, 0.9470). The proposed GEE mixed model method showed better correlation than the Pearson correlation analysis in each RNFL thickness parameter between the two OCT measurements. Conclusions. Although the RNFL thickness measurements obtained by the TD-OCT system correlated well with those obtained by the SD-OCT system, clinicians should be cautious when interpreting RNFL thickness data for any subject undergoing longitudinal follow-up with different OCTs. (Optom Vis Sci 2011; 88: 1326-1332)
引用
收藏
页码:1326 / 1332
页数:7
相关论文
共 31 条
[1]   Determinants of normal retinal nerve fiber layer thickness measured by stratus OCT [J].
Budenz, Donald L. ;
Anderson, Douglas R. ;
Varma, Rohit ;
Schuman, Joel ;
Cantor, Louis ;
Savell, Jonathan ;
Greenfeld, David S. ;
Patella, Vincent Michael ;
Quigley, Harry A. ;
Tielsch, James .
OPHTHALMOLOGY, 2007, 114 (06) :1046-1052
[2]   Optical coherence tomography machine learning classifiers for glaucoma detection: A preliminary study [J].
Burgansky-Eliash, Z ;
Wollstein, G ;
Chu, TJ ;
Ramsey, JD ;
Glymour, C ;
Noecker, RJ ;
Ishikawa, H ;
Schuman, JS .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (11) :4147-4152
[3]  
*C ZEISS MED INC, 2008, CIRR HD OCT US MAN R
[4]  
Caprioli J, 1998, INVEST OPHTH VIS SCI, V39, P2321
[5]   Discrimination between normal and glaucomatous eyes using Stratus optical coherence tomography in Taiwan Chinese subjects [J].
Chen, HY ;
Huang, ML .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 243 (09) :894-902
[6]   Spectral domain optical coherence tomography - Ultra-high speed, ultra-high resolution ophthalmic imaging [J].
Chen, TC ;
Cense, B ;
Pierce, MC ;
Nassif, N ;
Park, BH ;
Yun, SH ;
White, BR ;
Bouma, BE ;
Tearney, GJ ;
de Boer, JF .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (12) :1715-1720
[7]  
Diggle Peter, 2002, Analysis of longitudinal data
[8]   Relationship between central corneal thickness and retinal nerve fiber layer thickness in ocular hypertensive patients [J].
Henderson, PA ;
Medeiros, FA ;
Zangwill, LM ;
Weinreb, RN .
OPHTHALMOLOGY, 2005, 112 (02) :251-256
[9]   Development and comparison of automated classifiers for glaucoma diagnosis using stratus optical coherence tomography [J].
Huang, ML ;
Chen, HY .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (11) :4121-4129
[10]   Effect of Myopia on the Thickness of the Retinal Nerve Fiber Layer Measured by Cirrus HD Optical Coherence Tomography [J].
Kang, Shin Hee ;
Hong, Seung Woo ;
Im, Seong Kyu ;
Lee, Sang Hyup ;
Ahn, Myung Douk .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (08) :4075-4083