Organizational model and reactions to alerts in remote monitoring of cardiac implantable electronic devices: A survey from the Home Monitoring Expert Alliance project

被引:31
|
作者
Zanotto, Gabriele [1 ]
D'Onofrio, Antonio [2 ]
Della Bella, Paolo [3 ]
Solimene, Francesco [4 ]
Pisano, Ennio C. [5 ]
Iacopino, Saverio [6 ]
Dondina, Cristina [7 ]
Giacopelli, Daniele [7 ]
Gargaro, Alessio [7 ]
Ricci, Renato P. [8 ]
机构
[1] Osped Mater Salutis, Legnago, Italy
[2] Osped Monaldi, Naples, Italy
[3] Osped San Raffaele, Milan, Italy
[4] Clin Montevergine, Mercogliano, Italy
[5] Osped Vito Fazzi, Lecce, Italy
[6] Villa Maria Care & Res, Cotignola, Italy
[7] BIOTRONIK Italia, Vimodrone, Italy
[8] Cardio Arrhythmol Ctr, Rome, Italy
关键词
atrial fibrillation; cardiac resynchronization therapy; implantable cardioverter defibrillator; remote monitoring; telemonitoring; pacemaker; FOLLOW-UP; HEART-FAILURE; PACEMAKER PATIENTS; DEFIBRILLATORS; ASSOCIATION; SURVIVAL; EVENTS; SHOCKS; ICD;
D O I
10.1002/clc.23108
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background This survey aimed to describe the organizational workflow of cardiac implantable electronic devices (CIEDs) remote monitoring (RM) service in ordinary practice. Methods A questionnaire was designed for our purpose and completed by 49 sites participating to the Italian Home Monitoring Expert Alliance. Results A dedicated organizational model for RM was set up for 86% of centers. The median RM team consisted of 2 (Interquartile range [IQR]: 1-3) physicians and 1 (IQR: 0-2) nurse. RM service was available in working hours and the median percentage of patients included was 100% (IQR: 10%-100%) for implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy (CRT) recipients and 5% (IQR:0%-30%) for pacemakers. In-office follow-up was performed every 12 and 6 months for pacemaker and ICD/CRT recipients, respectively. More than 90% of sites used to activate all technical alerts, with a prompt reaction in case of an out-of-range parameter. The threshold for atrial fibrillation (AF) daily burden notification in most cases ranged from 2.4 to 7.2 hours. All ventricular arrhythmias alerts were usually switched on: an inappropriate therapy or more than one appropriate episode triggered an urgent in-hospital visit. Concerning heart failure, low CRT percentage pacing alert was always used, while the other available notifications were less frequently switched on. Conclusions This survey showed that RM service was usually set up with a primary nursing model including on average two responsible physicians and one nurse and mainly offered to ICD/CRT patients. Technical, AF and ventricular arrhythmia alerts triggered prompt reactions, while heart failure related indexes were generally less applied.
引用
收藏
页码:76 / 83
页数:8
相关论文
共 50 条
  • [31] Remote monitoring and follow-up of cardiovascular implantable electronic devices in the Netherlands An expert consensus report of the Netherlands Society of Cardiology
    de Cock, C. C.
    Elders, J.
    van Hemel, N. M.
    van den Broek, K.
    van Erven, L.
    de Mol, B.
    Talmon, J.
    Theuns, D. A. M. J.
    de Voogt, W.
    NETHERLANDS HEART JOURNAL, 2012, 20 (02) : 53 - 65
  • [32] Remote Monitoring of Cardiovascular Implantable Electronic Devices: New Questions Raised
    Joglar, Jose A.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (12): : 1489 - 1491
  • [33] Remote monitoring for follow-up of patients with implantable cardiac devices
    Oliveira, Mario
    Cunha, Pedro Silva
    da Silva, Nogueira
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2013, 32 (03) : 185 - 190
  • [34] Impact of COVID-19 Pandemic on Remote Monitoring of Cardiac Implantable Electronic Devices in Italy: Results of a Survey Promoted by AIAC (Italian Association of Arrhythmology and Cardiac Pacing)
    Maines, Massimiliano
    Palmisano, Pietro
    Del Greco, Maurizio
    Melissano, Donato
    De Bonis, Silvana
    Baccillieri, Stella
    Zanotto, Gabriele
    D'Onofrio, Antonio
    Ricci, Renato Pietro
    De Ponti, Roberto
    Boriani, Giuseppe
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (18)
  • [35] Strategies to enhance remote monitoring adherence among patients with cardiovascular implantable electronic devices
    Rotering, Thomas L.
    Hysong, Sylvia J.
    Williams, Katherine E.
    Raitt, Merritt H.
    Whooley, Mary A.
    Dhruva, Sanket S.
    HEART RHYTHM O2, 2023, 4 (12): : 794 - 804
  • [36] Remote monitoring of cardiac implantable electronic devices to predict acute clinical decompensation events
    Tinoco, Mariana
    Castro, Margarida
    Mota, Marta
    Almeida, Filipa
    Ribeiro, Silvia
    Faria, Bebiana
    Calvo, Lucy
    Cardoso, Filipa
    Sanfins, Victor
    Lourenco, Antonio
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, : 1300 - 1307
  • [37] Impact of the COVID-19 pandemic on implantation of cardiac implantable electronic devices and remote monitoring activations
    Garcia-Fernandez, F. J.
    Simal, Sara Calvo
    Perez, Oscar Cano
    Cuervo, David Calvo
    Jimenez, Marta Pombo
    Lozano, Ignacio Fernandez
    Tercedor, Lola Villagraz
    Palacios, Gonzalo Fernandez
    Gonzalez, Javier Martin
    REVISTA ESPANOLA DE CARDIOLOGIA, 2024, 77 (03): : 243 - 253
  • [38] False remote monitoring alerts from explanted cardiac implantable electronic device: How is this possible?
    Heath, Kyle M.
    Lyrtzis, Ellen
    Middeldorp, Melissa E.
    Sanders, Prashanthan
    Lau, Dennis H.
    JOURNAL OF ELECTROCARDIOLOGY, 2020, 62 : 132 - 133
  • [39] Remote Monitoring of Cardiac Implantable Electronic Devices: What is the Evidence?
    Adrian Reinhardt
    Rodolfo Ventura
    Current Heart Failure Reports, 2023, 20 : 12 - 23
  • [40] Remote monitoring of cardiac implantable electronic devices in Europe: results of the European Heart Rhythm Association survey
    Hernandez-Madrid, Antonio
    Lewalter, Thorsten
    Proclemer, Alessandro
    Pison, Laurent
    Lip, Gregory Y. H.
    Blomstrom-Lundqvist, Carina
    EUROPACE, 2014, 16 (01): : 129 - 132