Deformable Image Registration with a Featurelet Algorithm - Implementation as a 3D-Slicer Extension and Validation

被引:0
作者
Renner, A. [1 ,4 ]
Furtad, H. [2 ,3 ]
Seppenwoolde, Y. [1 ,3 ]
Birkfellner, W. [2 ,3 ]
Georg, D. [1 ,3 ]
机构
[1] Med Univ Vienna, Dept Radiat Oncol, Vienna, Austria
[2] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Vienna, Austria
[3] Med Univ Vienna, Christian Doppler Lab Med Radiat Res Radiat Oncol, Vienna, Austria
[4] Vienna Univ Technol, Inst Appl Phys, Vienna, Austria
来源
MEDICAL IMAGING 2016: IMAGE PROCESSING | 2016年 / 9784卷
关键词
Image-guided radiotherapy; tumor motion; non-rigid registration; open source; 3D Slicer; graphical user interface; Featurelet; INTENSITY-MODULATED RADIOTHERAPY; 3D SLICER; CANCER;
D O I
10.1117/12.2216863
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A radiotherapy (RT) treatment can last for several weeks. In that time organ motion and shape changes introduce uncertainty in dose application. Monitoring and quantifying the change can yield a more precise irradiation margin definition and thereby reduce dose delivery to healthy tissue and adjust tumor targeting. Deformable image registration (DIR) has the potential to fulfill this task by calculating a deformation field (DF) between a planning CT and a repeated CT of the altered anatomy. Application of the DF on the original contours yields new contours that can be used for an adapted treatment plan. DIR is a challenging method and therefore needs careful user interaction. Without a proper graphical user interface (GUI) a misregistration cannot be easily detected by visual inspection and the results cannot be fine-tuned by changing registration parameters. To provide a DIR algorithm with such a GUI available for everyone, we created the extension Featurelet-Registration for the open source software platform 3D Slicer. The registration logic is an upgrade of an in-house-developed DIR method, which is a featurelet-based piecewise rigid registration. The so called "featurelets" are equally sized rectangular subvolumes of the moving image which are rigidly registered to rectangular search regions on the fixed image. The output is a deformed image and a deformation field. Both can be visualized directly in 3D Slicer facilitating the interpretation and quantification of the results. For validation of the registration accuracy two deformable phantoms were used. The performance was benchmarked against a demons algorithm with comparable results.
引用
收藏
页数:6
相关论文
共 11 条
[1]   A margin-of-the-day online adaptive intensity-modulated radiotherapy strategy for cervical cancer provides superior treatment accuracy compared to clinically recommended margins: A dosimetric evaluation [J].
Ahmad, Rozilawati ;
Bondar, Luiza ;
Voet, Peter ;
Mens, Jan-Willem ;
Quint, Sandra ;
Dhawtal, Glenn ;
Heijmen, Ben ;
Hoogeman, Mischa .
ACTA ONCOLOGICA, 2013, 52 (07) :1430-1436
[2]   Toward an individualized target motion management for IMRT of cervical cancer based on model-predicted cervix-uterus shape and position [J].
Bondar, Luiza ;
Hoogeman, Mischa ;
Mens, Jan Willem ;
Dhawtal, Glenn ;
de Pree, Ilse ;
Ahmad, Rozilawati ;
Quint, Sandra ;
Heijmen, Ben .
RADIOTHERAPY AND ONCOLOGY, 2011, 99 (02) :240-245
[3]  
Castelli J., RAD ONE, V10
[4]  
Fabri D., 2014, THESIS
[5]   A quantitative comparison of the performance of three deformable registration algorithms in radiotherapy [J].
Fabri, Daniella ;
Zambrano, Valentina ;
Bhatia, Amon ;
Furtado, Hugo ;
Bergmann, Helmer ;
Stock, Markus ;
Bloch, Christoph ;
Luetgendorf-Caucig, Carola ;
Pawiro, Supriyanto ;
Georg, Dietmar ;
Birkfellner, Wolfgang ;
Figl, Michael .
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2013, 23 (04) :279-290
[6]   3D Slicer as an image computing platform for the Quantitative Imaging Network [J].
Fedorov, Andriy ;
Beichel, Reinhard ;
Kalpathy-Cramer, Jayashree ;
Finet, Julien ;
Fillion-Robin, Jean-Christophe ;
Pujol, Sonia ;
Bauer, Christian ;
Jennings, Dominique ;
Fennessy, Fiona ;
Sonka, Milan ;
Buatti, John ;
Aylward, Stephen ;
Miller, James V. ;
Pieper, Steve ;
Kikinis, Ron .
MAGNETIC RESONANCE IMAGING, 2012, 30 (09) :1323-1341
[7]   SlicerRT: Radiation therapy research toolkit for 3D Slicer [J].
Pinter, Csaba ;
Lasso, Andras ;
Wang, An ;
Jaffray, David ;
Fichtinger, Gabor .
MEDICAL PHYSICS, 2012, 39 (10) :6332-6338
[8]   Model-independent, multimodality deformable image registration by local matching of anatomical features and minimization of elastic energy [J].
Soehn, Matthias ;
Birkner, Mattias ;
Chi, Yuwei ;
Wang, Jian ;
Yan, Di ;
Berger, Bernhard ;
Alber, Markus .
MEDICAL PHYSICS, 2008, 35 (03) :866-878
[9]   Deformable Medical Image Registration: A Survey [J].
Sotiras, Aristeidis ;
Davatzikos, Christos ;
Paragios, Nikos .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (07) :1153-1190
[10]   AUTOMATED WEEKLY REPLANNING FOR INTENSITY-MODULATED RADIOTHERAPY OF CERVIX CANCER [J].
Stewart, James ;
Lim, Karen ;
Kelly, Valerie ;
Xie, Jason ;
Brock, Kristy K. ;
Moseley, Joanne ;
Cho, Young-Bin ;
Fyles, Anthony ;
Lundin, Anna ;
Rehbinder, Henrik ;
Lof, Johan ;
Jaffray, David ;
Milosevic, Michael .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (02) :350-358