摘要
The solar absorption-subcooled compression hybrid cooling system (SASCHCS) is tech-economically feasible for high-rise buildings. Since such a system operates with no auxiliary heat source, the performance coupling of its absorption subsystem and solar collectors is sensitive to the variation of hot water flow rate. In this regard, the relationship of system performance and hot water flow rate is required to be clarified exactly. Therefore, this paper aims to illustrate the effect mechanism of hot water flow rate and to propose the corresponding decision criterion. The case study is based on a typical high-rise office building in subtropical Guangzhou. The daily working process of this system with different hot water flow rates is simulated and analyzed. Subsequently, the useful heat of collectors and cooling capacity of the absorption subsystem with the hot water flow rate is discussed in detail. The results show that the SASCHCS operates with hot water temperatures ranging from 60 degrees C to 90 degrees C. The energy saving increases with the rise of hot water flow rate, but such variation tends to be flat for the excessively high flow rate. As the collector flow rate increases from 1 m(3)/h to 10 m(3)/h, the daily energy saving improves by 21% in August. Similarly, the daily energy saving increases by 37.5% as generator hot water flow rate increases from 1 m(3)/h to 10 m(3)/h. In addition, the collector flow rate of 3.6 m(3)/h (13.33 (kg/m(2)h)) and the generator flow rate of 5.2 m(3)/h (19.26 (kg/m(2)h)) are optimal for the annual operation, with considering power consumption of water pumps. This paper is helpful for the improvement of SASCHCS operating performance.
引用
收藏
页数:17
相关论文
共 31 条
[11]   Off-Design Modeling and Simulation of Solar Absorption-Subcooled Compression Hybrid Cooling System [J].
Li, Zeyu ;
Yu, Jianting ;
Chen, Erjian ;
Jing, Yue .
APPLIED SCIENCES-BASEL, 2018, 8 (12)
[12]   Economic and environmental study of solar absorption-subcooled compression hybrid cooling system [J].
Li, Zeyu ;
Liu, Liming .
INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2019, 38 (02) :123-140
[13]   Thermodynamic relationship of subcooling power and increase of cooling output in vapour compression chiller [J].
Li, Zeyu ;
Chen, Erjian ;
Jing, Yue ;
Lv, Shiliang .
ENERGY CONVERSION AND MANAGEMENT, 2017, 149 :254-262
[14]   Exergoeconomic analysis of solar absorption-subcooled compression hybrid cooling system [J].
Li, Zeyu ;
Liu, Liming ;
Jing, Yue .
ENERGY CONVERSION AND MANAGEMENT, 2017, 144 :205-216
[15]   Performance analysis of solar air cooled double effect LiBr/H2O absorption cooling system in subtropical city [J].
Li, Zeyu ;
Ye, Xiangyang ;
Liu, Jinping .
ENERGY CONVERSION AND MANAGEMENT, 2014, 85 :302-312
[16]   Performance prediction of a solar/gas driving double effect LiBr-H2O absorption system [J].
Liu, YL ;
Wang, RZ .
RENEWABLE ENERGY, 2004, 29 (10) :1677-1695
[17]   Thermal performance analysis of the glass evacuated tube solar collector with U-tube [J].
Ma, Liangdong ;
Lu, Zhen ;
Zhang, Jili ;
Liang, Ruobing .
BUILDING AND ENVIRONMENT, 2010, 45 (09) :1959-1967
[18]   Simulation of solar lithium bromide-water absorption cooling system with parabolic trough collector [J].
Mazloumi, M. ;
Naghashzadegan, M. ;
Javaherdeh, K. .
ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) :2820-2832
[19]  
Miao D., 1978, NASA TECHNICAL PAPER, P1296
[20]   Comprehensive Parametric Study of a Solar Absorption Refrigeration System to Lower Its Cut In/Off Temperature [J].
Mohammed, Osman Wageiallah ;
Guo Yanling .
ENERGIES, 2017, 10 (11)