Design and Cooling Properties of High Stable Field REBCO Superconducting Magnet for MRI

被引:24
作者
Yokoyama, Shoichi [1 ]
Kiss, Takanobu [3 ]
Miyagi, Daisuke [4 ]
Tsuda, Makoto [5 ]
Nakamura, Taketsune [6 ]
Shirai, Yasuyuki [6 ]
Miura, Hideaki [1 ]
Matsuda, Tetsuya [1 ]
Inoue, Tatsuya [2 ]
Morita, Yusuke [2 ]
Eguchi, Ryo [2 ]
Otake, Shunsuke [2 ]
Tanabe, Hajime [2 ]
Sato, Shinji [1 ]
机构
[1] Mitsubishi Electr Corp, Adv Technol R&D Ctr, Amagasaki, Hyogo 6618661, Japan
[2] Mitsubishi Electr Corp, Transmiss & Distribut Syst Ctr, Ako, Hyogo 6780256, Japan
[3] Kyushu Univ, Fukuoka 8190395, Japan
[4] Chiba Univ, Chiba 2638522, Japan
[5] Tohoku Univ, Sendai, Miyagi 9808579, Japan
[6] Kyoto Univ, Kyoto 6068507, Japan
关键词
Superconducting magnet; magnetic resonance imaging (MRI); high-temperature superconducting (HTS); liquid helium free; REBCO coil; field stability; field homogeneity;
D O I
10.1109/TASC.2020.2973936
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Research and development for the practical application of a medical-use magnetic resonance imaging system (MRI) superconducting magnet that does not require liquid helium started as the New Energy and Industrial Technology Development Organization's (NEDO) supported project in fiscal 2016. Development of a liquid helium-free medical MRI superconducting magnet has been desired. Another purpose is to reduce the size and weight of high magnetic field magnets. By using the high temperature superconducting coil, it is possible to make the 3T magnet of the same shape, weight, leakage magnetic field as 1.5T magnet. In this project, we are developing a half size active shield-type 3T REBCO coil for MRI. This magnet has active shield coils with a maximum diameter of 1200 mm, and its room bore diameter is 480 mm. This magnet is one of the world's largest magnets using a REBCO wire with an accumulated energy of 1.6 MJ at the rated magnetic field. It generates a magnetic field of high homogeneity and stability necessary for imaging. In this paper, we report the half-size active shield-type 3T coil and its cooling system that can reduce the initial cooling time by thermal switches.
引用
收藏
页数:4
相关论文
共 15 条
[1]  
Imura T., 2014, P CSSJ C, V89
[2]  
Miura H., 2019, P J PHYS C SERIE SEP
[3]   Magnetic Design of a Half-Size 5 T High-Temperature Superconducting Coil for MRI [J].
Miura, Hideaki ;
Matsuda, Tetsuya ;
Nomura, Kota ;
Yokoyama, Shoichi ;
Morita, Yusuke ;
Otake, Shunsuke ;
Inoue, Tatsuya ;
Tanabe, Hajime ;
Sato, Shinji .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (05)
[4]   Estimation Method of Optimal Amount of Overshooting Current for Temporal Uniform Magnetic Field in Conduction-Cooled HTS Coils [J].
Miura, Hideaki ;
Miyazaki, Jun ;
Ide, Momoe ;
Miyagi, Daisuke ;
Tsuda, Makoto ;
Yokoyama, Shoichi .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2018, 28 (03)
[5]  
Nakamura T., 2014, P CSSJ C, V89
[6]  
Shibayama Y., 2014, P CSSJ C, V89
[7]   Generalized Kac lemma for recurrence time in iterated open quantum systems [J].
Sinkovicz, P. ;
Kiss, T. ;
Asboth, J. K. .
PHYSICAL REVIEW A, 2016, 93 (05)
[8]   Magnetic Field Stability Control of HTS-MRI Magnet by Use of Highly Stabilized Power Supply [J].
Yachida, Takayuki ;
Yoshikawa, Masaki ;
Shirai, Yasuyuki ;
Matsuda, Tetsuya ;
Yokoyama, Shoichi .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)
[9]   A CONCEPTUAL DESIGN OF A SUPERCONDUCTING MAGNET FOR MAGLEV USING A BI-BASED HIGH-TC TAPE [J].
YOKOYAMA, S ;
SHIMOHATA, K ;
INAGUCHI, T ;
TAKEUCHI, T ;
KIM, T ;
NAKAMURA, S ;
MIYASHITA, S ;
UCHIKAWA, F .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1995, 5 (02) :610-613
[10]   Design of a half-size 3T REBCO superconducting magnet with active shielding coils for MRI [J].
Yokoyama, S. ;
Miura, H. ;
Matsuda, T. ;
Inoue, T. ;
Morita, Y. ;
Otake, S. ;
Sato, S. .
27TH INTERNATIONAL CRYOGENICS ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2018 (ICEC-ICMC 2018), 2019, 502