Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions

被引:62
作者
Haiter-Neto, F. [1 ]
Wenzel, A. [2 ]
Gotfredsen, E. [2 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Dentomaxillofacial Radiol Area, BR-13414901 Piracicaba, SP, Brazil
[2] Univ Aarhus, Dept Oral Dent, Sch Dent, DK-8000 Aarhus C, Denmark
关键词
radiography; digital; computed tomography; diagnosis; dental caries;
D O I
10.1259/dmfr/87103878
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim was to compare the caries diagnostic accuracy of two cone beam CT systems (CBCT) with two intraoral receptors, one digital and one film. Methods: 100 non-cavitated extracted human teeth were placed with approximal contacts: each row of teeth comprised I canine, I first and second premolar., and I first and second molar. Radiographs of each tooth were recorded using two intraoral modalities: Digora-fmx (Soredex) and film (Kodak Insight), and two CBCT systems: NewTom 3G (Quantitative Radiology) in three fields of view (FOVs): pixel size of 0.36 mm (FOV 12 inches), pixel size of 0.25 mm (FOV 9 inches), pixel size of 0.16 mm (FOV 6 inches); and 3DX Accuitomo (Morita), pixel size of 0.125 (FOV 4 cm). The volumetric data from the CBCT systems were reconstructed and sectioned (0.5 mm) in the mesiodistal tooth plane. Six observers scored approximal and occlusal surfaces for the detection of caries lesions. The teeth were clinically sectioned and microscopy served as the validation tool. Two-way ANOVA tested differences in sensitivity, specificity and overall true score (true positives plus true negatives) between the modalities. Results: Microscopy of approximal surfaces found 63% sound, 3101 enamel and 6% dentin lesions; of occlusal surfaces, 6% sound, 59% enamel, 19% dentin lesions and 16% had fillings. For approximal surfaces, NewTom 12 inch and 9 inch images had significantly lower sensitivities than Accuitomo (P < 0.02); and NewTom 9 inch and 6 inch had significantly lower specificities than film and Digora-fmx (P < 0.04). Accuitomo images were not significantly different from film or Digora-fmx images for any of the tested variables (P > 0.2). For occlusal surfaces, the Accuitomo presented a higher sensitivity than the other systems. Specificity and overall true score did not differ (P > 0.06) among the modalities. Conclusions: In conclusion, the NewTom 3G CBCT had a lower diagnostic accuracy for detection of caries lesions than intraoral modalities and the 3DX Accuitomo CBCT. The Accuitomo CBCT had a higher sensitivity than the intraoral systems for detection of lesions in dentin, but the overall true score was not higher.
引用
收藏
页码:18 / 22
页数:5
相关论文
共 28 条
  • [1] Accuracy of proximal caries depth measurements:: Comparison between limited cone beam computed tomography, storage phosphor and film radiography
    Akdeniz, B. Guniz
    Grondahl, Hans-Goran
    Magnusson, Bengt
    [J]. CARIES RESEARCH, 2006, 40 (03) : 202 - 207
  • [2] Development of a compact computed tomographic apparatus for dental use
    Arai, Y
    Tammisalo, E
    Iwai, K
    Hashimoto, K
    Shinoda, K
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) : 245 - 248
  • [3] Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay™):: system configuration and physical properties
    Araki, K
    Maki, K
    Seki, K
    Sakamaki, K
    Harata, Y
    Sakaino, R
    Okano, T
    Seo, K
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (01) : 51 - 59
  • [4] Bianchi SD, 1998, INT CONGR SER, V1165, P792
  • [5] *COMM EUR COMM, 2004, EUR GUID RAD PROT DE
  • [6] Danforth Robert A, 2003, J Calif Dent Assoc, V31, P814
  • [7] ALARA still applies
    Farman, AG
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2005, 100 (04): : 395 - 397
  • [8] A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine
    Hashimoto, K
    Arai, Y
    Iwai, K
    Araki, M
    Kawashima, S
    Terakado, M
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2003, 95 (03): : 371 - 377
  • [9] Influence of the validation method on diagnostic accuracy for caries. A comparison of six digital and two conventional radiographic systems
    Hintze, H
    Wenzel, A
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (01) : 44 - 49
  • [10] Accuracy of caries detection with four storage phosphor systems and E-speed radiographs
    Hintze, H
    Wenzel, A
    Frydenberg, M
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (03) : 170 - 175