Higher Order Reconstruction for MRI in the Presence of Spatiotemporal Field Perturbations

被引:135
作者
Wilm, Bertram J.
Barmet, Christoph
Pavan, Matteo
Pruessmann, Klaas P. [1 ]
机构
[1] ETH, Inst Biomed Engn, Zurich, Switzerland
关键词
magnetic field monitoring; diffusion imaging; DTI; Eddy current correction; algebraic image reconstruction; EDDY-CURRENT ARTIFACTS; DISTORTION CORRECTION; GEOMETRIC DISTORTION; GRADIENTS; ELIMINATION; REDUCTION; MAGNETS; EPI;
D O I
10.1002/mrm.22767
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Despite continuous hardware advances, MRI is frequently subject to field perturbations that are of higher than first order in space and thus violate the traditional k-space picture of spatial encoding. Sources of higher order perturbations include eddy currents, concomitant fields, thermal drifts, and imperfections of higher order shim systems. In conventional MRI with Fourier reconstruction, they give rise to geometric distortions, blurring, artifacts, and error in quantitative data. This work describes an alternative approach in which the entire field evolution, including higher order effects, is accounted for by viewing image reconstruction as a generic inverse problem. The relevant field evolutions are measured with a third-order NMR field camera. Algebraic reconstruction is then formulated such as to jointly minimize artifacts and noise in the resulting image. It is solved by an iterative conjugate-gradient algorithm that uses explicit matrix-vector multiplication to accommodate arbitrary net encoding. The feasibility and benefits of this approach are demonstrated by examples of diffusion imaging. In a phantom study, it is shown that higher order reconstruction largely overcomes variable image distortions that diffusion gradients induce in EPI data. In vivo experiments then demonstrate that the resulting geometric consistency permits straightforward tensor analysis without coregistration. Magn Reson Med 65:1690-1701, 2011. (C) 2011 Wiley-Liss, Inc.
引用
收藏
页码:1690 / 1701
页数:12
相关论文
共 60 条
  • [1] Elimination of eddy current artifacts in diffusion-weighted echo-planar images: The use of bipolar gradients
    Alexander, AL
    Tsuruda, JS
    Parker, DL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (06) : 1016 - 1021
  • [2] Gradient characterization using a Fourier-transform technique
    Alley, MT
    Glover, GH
    Pelc, NJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) : 581 - 587
  • [3] [Anonymous], 1894, Analytische Zahlentheorie
  • [4] [Anonymous], 1973, A Course of Modern Analysis
  • [5] Barmet C, 2009, P ISMRM 17 SCI M EXH
  • [6] Barmet C., 2010, Proc. Intl. Soc. Mag. Reson. Med., V18, P216
  • [7] Spatiotemporal magnetic field monitoring for MR
    Barmet, Christoph
    De Zanche, Nicola
    Pruessmann, Klaas P.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (01) : 187 - 197
  • [8] A Transmit/Receive System for Magnetic Field Monitoring of In Vivo MRI
    Barmet, Christoph
    De Zanche, Nicola
    Wilm, Bertram J.
    Pruessmann, Klaas P.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) : 269 - 276
  • [9] Inferring microstructural features and the physiological state of tissues from diffusion-weighted images
    Basser, PJ
    [J]. NMR IN BIOMEDICINE, 1995, 8 (7-8) : 333 - 344
  • [10] Rapid gridding reconstruction with a minimal oversampling ratio
    Beatty, PJ
    Nishimura, DG
    Pauly, JM
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (06) : 799 - 808