Discrimination of Substandard and Falsified Formulations from Genuine Pharmaceuticals Using NIR Spectra and Machine Learning

被引:21
作者
Awotunde, Olatunde [1 ]
Roseboom, Nicholas [1 ]
Cai, Jin [1 ]
Hayes, Kathleen [1 ]
Rajane, Revati [2 ]
Chen, Ruoyan [2 ]
Yusuf, Abdullah [2 ]
Lieberman, Marya [1 ]
机构
[1] Univ Notre Dame, Dept Chem & Biochem, Notre Dame, IN 46556 USA
[2] Precise Software Solut Inc, Rockville, MD 20850 USA
关键词
NEAR-INFRARED SPECTROSCOPY; TABLETS; QUANTIFICATION; IDENTIFICATION; CHEMOMETRICS; INGREDIENTS; PARACETAMOL; CALIBRATION; DESIGN; RAMAN;
D O I
10.1021/acs.analchem.2c00998
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Near-infrared (NIR) spectroscopy is a promising technique for field identification of substandard and falsified drugs because it is portable, rapid, nondestructive, and can differentiate many formulated pharmaceutical products. Portable NIR spectrometers rely heavily on chemometric analyses based on libraries of NIR spectra from authentic pharmaceutical samples. However, it is difficult to build comprehensive product libraries in many low- and middle-income countries due to the large numbers of manufacturers who supply these markets, frequent unreported changes in materials sourcing and product formulation by the manufacturers, and general lack of cooperation in providing authentic samples. In this work, we show that a simple library of lab-formulated binary mixtures of an active pharmaceutical ingredient (API) with two diluents gave good performance on field screening tasks, such as discriminating substandard and falsified formulations of the API. Six data analysis models, including principal component analysis and supportvector machine classification and regression methods and convolutional neural networks, were trained on binary mixtures of acetaminophen with either lactose or ascorbic acid. While the models all performed strongly in cross-validation (on formulations similar to their training set), they individually showed poor robustness for formulations outside the training set. However, a predictive algorithm based on the six models, trained only on binary samples, accurately predicts whether the correct amount of acetaminophen is present in ternary mixtures, genuine acetaminophen formulations, adulterated acetaminophen formulations, and falsified formulations containing substitute APIs. This data analytics approach may extend the utility of NIR spectrometers for analysis of pharmaceuticals in low-resource settings.
引用
收藏
页码:12586 / 12594
页数:9
相关论文
共 64 条
[51]   Simple assessment of homogeneity in pharmaceutical mixing processes using a near-infrared reflectance probe and control charts [J].
Skibsted, ETS ;
Boelens, HFM ;
Westerhuis, JA ;
Witte, DT ;
Smilde, AK .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (01) :26-35
[52]   Light leakage effects with different sample holder geometries in quantitative near-infrared transmission spectroscopy of pharmaceutical tablets [J].
Sparén, A ;
Malm, M ;
Josefson, M ;
Folestad, S ;
Johansson, J .
APPLIED SPECTROSCOPY, 2002, 56 (05) :586-592
[53]   Expanding the analytical toolbox for identity testing of pharmaceutical ingredients: Spectroscopic screening of dextrose using portable Raman and near infrared spectrometers [J].
Srivastava, Hirsch K. ;
Wolfgang, Steven ;
Rodriguez, Jason D. .
ANALYTICA CHIMICA ACTA, 2016, 914 :91-99
[54]  
The Pathology of Negligence, 2012, REPORT JUDICIAL INQU
[55]   Open-source python']python module for automated preprocessing of near infrared spectroscopic data [J].
Torniainen, Jari ;
Afara, Isaac O. ;
Prakash, Mithilesh ;
Sarin, Jaakko K. ;
Stenroth, Lauri ;
Toyras, Juha .
ANALYTICA CHIMICA ACTA, 2020, 1108 :1-9
[56]  
WHO, 2017, 70 WORLD HLTH ASS UP, V41
[57]   Evaluation of the performance of three hand-held near-infrared spectrometer through investigation of total antioxidant capacity in gluten free grains [J].
Wiedemair, Verena ;
Huck, Christian W. .
TALANTA, 2018, 189 :233-240
[58]  
World Health Organization, 2019, WHO MEMB STAT MECH S
[59]   Quality-by-Design (QbD): An integrated multivariate approach for the component quantification in powder blends [J].
Wu, Huiquan ;
Tawakkul, Mobin ;
White, Maury ;
Khan, Mansoor A. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2009, 372 (1-2) :39-48
[60]   Development of robust quantitative methods by near-infrared spectroscopy for rapid pharmaceutical determination of content uniformity in complex tablet matrix [J].
Xiang, Dong ;
Konigsberger, Michele ;
Wabuyele, Busolo ;
Hornung, Karl ;
Cheney, James .
ANALYST, 2009, 134 (07) :1405-1415