Clinical Value of Patient-Specific Three-Dimensional Printing of Kidney Before Partial Nephrectomy: A Qualitative Assessment

被引:5
|
作者
Nayyar, Rishi [1 ]
Sharma, Kulbhushan [1 ]
Saini, Sumit [1 ]
Das, Chandan J. [2 ]
Singh, Prabhjot [1 ]
Nayak, Brusabhanu [1 ]
Panaiyadiyan, Sridhar [1 ]
Seth, Amlesh [1 ]
机构
[1] All India Inst Med Sci, Dept Urol, New Delhi 110029, India
[2] All India Inst Med Sci, Dept Radiol, New Delhi, India
关键词
3D printing; complex renal tumors; partial nephrectomy; quality assessment; MODELS;
D O I
10.1089/end.2020.1103
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To qualitatively assess the clinical usefulness of patient-specific high-fidelity three-dimensional (3D) print model of kidney before partial nephrectomy (PN) and to identify subset domains where it may help in clinical terms. Materials and Methods: Thirteen 3D models were printed for tumors having RENAL nephrometry score of >= 8. Their usage for PN was assessed prospectively using a qualitative questionnaire to be answered on a Likert scale of 1-10. The questions focused on realistic resemblance, preoperative dry surgical run, intertest comparison, surgical impact, and overall beneficence domains as perceived by primary surgeons with respect to surgical conduct during PN. Results: Mean RENAL score was 9.15 (8-11). Models were rated high (9.07 +/- 0.86) for realistic resemblance domain and were rated better than contrast-enhanced computed tomography (CECT) (8.38 +/- 0.87) and intraoperative ultrasonography (8.07 +/- 1.26) for orientation regarding resection margins. A further marginal improvement to 8.2 +/- 0.84 was noted against ultrasound where surgeon did a dry cut preoperatively. Use of superselective arterial approach in four, precise awareness about dissection of a major vessel in four, retroperitoneoscopic approach in one, and surgical margin awareness in three were directly attributed to the model. Overall utility of having a model printed was rated high (8.23 +/- 1.3). Conclusion: The 3D print models of complex renal tumors have high realistic resemblance to actual patient's anatomy. They were rated better than preoperative CECT or intraoperative ultrasonography for orientation regarding surgical resection margins. It may also help change or modify the surgical plan in a subset of patients with a potential to improve overall outcomes in these complex cases.
引用
收藏
页码:1405 / 1410
页数:6
相关论文
共 50 条
  • [31] The application of full-size three-dimensional individual printed model combined with three-dimensional digital demonstration can facilitate patient’s preoperative comprehension to robotic-assisted laparoscopic partial nephrectomy
    Xiaobin Yuan
    Xiaolei Liu
    Qiang Jing
    Fan Liu
    Xuhui Zhang
    Perioperative Medicine, 11
  • [32] The application of full-size three-dimensional individual printed model combined with three-dimensional digital demonstration can facilitate patient's preoperative comprehension to robotic-assisted laparoscopic partial nephrectomy
    Yuan, Xiaobin
    Liu, Xiaolei
    Jing, Qiang
    Liu, Fan
    Zhang, Xuhui
    PERIOPERATIVE MEDICINE, 2022, 11 (01)
  • [33] Characterization and clinical validation of patient-specific three-dimensional printed tissue-equivalent bolus for radiotherapy of head and neck malignancies involving skin
    Dyer, Brandon A.
    Campos, David D.
    Hernandez, Daniel D.
    Wright, Cari L.
    Perks, Julian R.
    Lucero, Steven A.
    Bewley, Arnaud F.
    Yamamoto, Tokihiro
    Zhu, Xiandong
    Rao, Shyam S.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 138 - 145
  • [34] Three-Dimensional Microwave Breast Imaging: Dispersive Dielectric Properties Estimation Using Patient-Specific Basis Functions
    Winters, David W.
    Shea, Jacob D.
    Kosmas, Panagiotis
    Van Veen, Barry D.
    Hagness, Susan C.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (07) : 969 - 981
  • [35] Three-Dimensional Planning and Patient-Specific Drill Guides for Repair of Spondylolysis/L5 Pars Defect
    Mobbs, Ralph J.
    Choy, Wen Jie
    Singh, Telvinderjit
    Cassar, Lachlan
    Davidoff, Chris
    Harris, Leigh
    Phan, Kevin
    Fiechter, Meinrad
    WORLD NEUROSURGERY, 2019, 132 : 75 - 80
  • [36] A patient-specific three-dimensional couplant pad for ultrasound image-guided radiation therapy: a feasibility study
    Heejung Kim
    Ah Ram Chang
    Sungwoo Cho
    Sung-Joon Ye
    Radiation Oncology, 13
  • [37] Three-Dimensional Heart Modeling of Hypertrophic Obstructive Cardiomyopathy for In Situ Patient-Specific Simulation to Optimize Septal Myectomy
    Smits, Karin C.
    Speekenbrink, Ron G. H.
    Hekman, Edsko E. G.
    Koenrades, Maaike A.
    Heeringa, Tijn J. P.
    Arens, Jutta
    Halfwerk, Frank R.
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2024, 19 (05) : 532 - 540
  • [38] A patient-specific three-dimensional couplant pad for ultrasound image-guided radiation therapy: a feasibility study
    Kim, Heejung
    Chang, Ah Ram
    Cho, Sungwoo
    Ye, Sung-Joon
    RADIATION ONCOLOGY, 2018, 13
  • [39] Design and Application of a Novel Patient-Specific Three-Dimensional Printed Drill Navigational Guiding in Atlantoaxial Pedicle Screw Placement
    Pu, Xinwei
    Yin, Mengchen
    Ma, Junming
    Liu, Yujie
    Chen, Guanghui
    Huang, Quan
    Zhao, Guoquan
    Lu, Tingsheng
    Yao, Shudan
    Chen, Qinlin
    Luo, Chunshan
    WORLD NEUROSURGERY, 2018, 114 : E1 - E10
  • [40] A three-dimensional printed silk-based biomimetic tri-layered meniscus for potential patient-specific implantation
    Bandyopadhyay, Ashutosh
    Mandal, Biman B.
    BIOFABRICATION, 2020, 12 (01)