Mechanomyographic and electromyographic responses of the vastus medialis muscle during isometric and concentric muscle actions

被引:3
|
作者
Coburn, JW [1 ]
Housh, TJ
Cramer, JT
Weir, JP
Miller, JM
Beck, TW
Malek, MH
Johnson, GO
机构
[1] Univ Nebraska, Lincoln, NE 68583 USA
[2] Univ Texas, Arlington, TX 76019 USA
[3] Des Moines Univ, Des Moines, IA 50312 USA
关键词
electromyography; mechanomyography; phonomyography; acoustic myography; quadriceps;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Coburn, JW., T.J. Housh, J.T. Cramer, J.P. Weir, J.M. Miller, T.W. Beek, M.H. Malek, and G.O. Johnson. Mechanomyographic and electromyographic responses of the vastus medialis muscle during isometric and concentric muscle actions. J. Strength Cond. Res. 19(2):412-420. 2005.-The purpose of this study was to examine the patterns for the mechanomyographic (MMG) and electromyographic (EMG) amplitude and mean power frequency (MPF) vs. torque relationships during submaximal to maximal isometric and isokinetic muscle actions. Seven men (mean +/- SD age, 22.4 +/- 1.3 years) volunteered to perform isometric and concentric isokinetic leg extension muscle actions at 20, 40, 60, 80, and 100% of maximal voluntary contraction (MVC) and peak torque (PT) on a Cybex II dynamometer. A piezoelectric MMG recording sensor was placed between bipolar surface EMG electrodes on the vastus medialis. Polynomial regression and separate 1-way repeated-measures analysis of variance were used to analyze the EMG amplitude, MMG amplitude, EMG MPF, and MMG MPF data for the isometric and isokinetic muscle actions. For the isometric muscle actions, EMG amplitude (R-2 = 0.999) and MMG MPF (R-2 = 0.946) increased to MVC, mean MMG amplitude increased to 60% MVC and then plateaued, and mean EMG MPF did not change (p > 0.05) across torque levels. For the isokinetic muscle actions, EMG amplitude (R-2 = 0.988) and MMG amplitude (R-2 = 0.933) increased to PT, but there were no significant mean changes with torque for EMG MPF or MMG MPF. The different torque-related responses for EMG and MMG amplitude and MPF may reflect differences in the motor control strategies that modulate torque production for isometric vs. dynamic muscle actions. These results support the findings of others and suggest that isometric torque production was modulated by a combination of recruitment and firing rate, whereas dynamic torque production was modulated primarily through recruitment.
引用
收藏
页码:412 / 420
页数:9
相关论文
共 50 条
  • [1] Mechanomyographic responses of the vastus medialis to isometric and eccentric muscle actions
    Coburn, JW
    Housh, TJ
    Weir, JP
    Malek, MH
    Cramer, JT
    Beck, TW
    Johnson, GO
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (11) : 1916 - 1922
  • [2] Gender, muscle, and velocity comparisons of mechanomyographic and electromyographic responses during isokinetic muscle actions
    Cramer, JT
    Housh, TJ
    Weir, JP
    Johnson, GO
    Berning, JM
    Perry, SR
    Bull, AJ
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2004, 14 (02) : 116 - 127
  • [3] Mechanomyographic and electromyographic responses to repeated concentric muscle actions of the quadriceps femoris
    Ebersole, KT
    O'Connor, KM
    Wier, AP
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2006, 16 (02) : 149 - 157
  • [4] Electromyographic and mechanomyographic responses across repeated maximal isometric and concentric muscle actions of the leg extensors
    Camic, Clayton L.
    Housh, Terry J.
    Zuniga, Jorge M.
    Hendrix, C. Russell
    Bergstrom, Haley C.
    Traylor, Daniel A.
    Schmidt, Richard J.
    Johnson, Glen O.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2013, 23 (02) : 342 - 348
  • [5] Mechanomyographic and electromyographic responses to eccentric and concentric isokinetic muscle actions of the biceps brachii
    Smith, DB
    Housh, TJ
    Johnson, GO
    Evetovich, TK
    Ebersole, KT
    Perry, SR
    MUSCLE & NERVE, 1998, 21 (11) : 1438 - 1444
  • [6] Mechanomyographic and electromyographic responses to eccentric muscle contractions
    Coburn, JW
    Housh, TJ
    Malek, MH
    Weir, JP
    Cramer, JT
    Beck, TW
    Johnson, GO
    MUSCLE & NERVE, 2006, 33 (05) : 664 - 671
  • [7] Mechanomyographic and electromyographic responses during submaximal to maximal eccentric isokinetic muscle actions of the biceps brachii
    Beck, TW
    Housh, TJ
    Johnson, GO
    Weir, JP
    Cramer, JT
    Coburn, JW
    Malek, MH
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2006, 20 (01) : 184 - 191
  • [8] An examination of mechanomyographic signal stationarity during concentric isokinetic, eccentric isokinetic and isometric muscle actions
    Beck, Travis W.
    DeFreitas, Jason M.
    Stock, Matt S.
    Dillon, Michael A.
    PHYSIOLOGICAL MEASUREMENT, 2010, 31 (03) : 339 - 361
  • [9] Mechanomyographic and electromyographic responses during fatigue in humans: influence of muscle length
    Weir, JP
    Ayers, KM
    Lacefield, JF
    Walsh, KL
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2000, 81 (04) : 352 - 359
  • [10] Mechanomyographic and electromyographic responses during fatigue in humans: influence of muscle length
    Joseph P. Weir
    Kristi M. Ayers
    Jennifer F. Lacefield
    Kara L. Walsh
    European Journal of Applied Physiology, 2000, 81 : 352 - 359