Reactive Desorption Electrospray Ionization Mass Spectrometry To Determine Intrinsic Degradability of Poly(lactic-co-glycolic acid) Chains

被引:6
作者
Fouquet, Thierry N. J. [4 ]
Amalian, Jean-Arthur [1 ]
Aniel, Nathan [1 ]
Carvin-Sergent, Isaure [1 ]
Issa, Sebastien [1 ]
Poyer, Salome [1 ]
Crozet, Delphine [2 ]
Giusti, Pierre [2 ,3 ]
Gigmes, Didier [1 ]
Trimaille, Thomas [1 ]
Charles, Laurence [1 ]
机构
[1] Aix Marseille Univ, Inst Chim Radicalaire, UMR7273, CNRS, F-13397 Marseille, France
[2] Total Res & Technol Gonfreville, Total Refining & Chem, F-76700 Harfleur, France
[3] Int Joint Lab iC2MC Complex Matrices Mol Characte, F-76700 Harfleur, France
[4] Natl Inst Adv Ind Sci & Technol, Res Inst Sustainable Chem, Tsukuba, Ibaraki 3058565, Japan
关键词
HYDROLYTIC DEGRADATION; DISSOCIATION; OLIGOMERS; PRODUCTS; PROTEINS; SURFACES; PLA;
D O I
10.1021/acs.analchem.1c02280
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Because of its speed, sensitivity, and ability to scrutinize individual species, mass spectrometry (MS) has become an essential tool in analytical strategies aimed at studying the degradation behavior of polyesters. MS analyses can be performed prior to the degradation event for structural characterization of initial substrates or after it has occurred to measure the decreasing size of products as a function of time. Here, we show that MS can also be usefully employed during the degradation process by online monitoring the chain solvolysis induced by reactive desorption electrospray ionization (DESI). Cleavage of ester bonds in random copolymers of lactic acid (LA) and glycolic acid (GA) was achieved by electrospraying methanol-containing NaOH onto the substrates. Experimental conditions were optimized to generate methanolysis products of high abundance so that mass spectra can be conveniently processed using Kendrick-based approaches. The same reactive-DESI performance was demonstrated for two sample preparations, solvent casting for soluble samples or pressed pellets for highly crystalline substrates, permitting to compare polymers with LA/GA ratios ranging from 100/0 to 5/95. Analysis of sample fractions collected by size exclusion chromatography showed that methanolysis occurs independently of the original chain size, so data recorded for poly(LA-co-GA) (PLAGA) copolymers with the average molecular weight ranging from 10 to 180 kDa could be safely compared. The average mass of methanolysis products was observed to decrease linearly (R-2 = 0.9900) as the GA content increases in PLAGA substrates, consistent with the susceptibility of ester bonds toward solvolysis being higher in GA than in LA. Because DESI only explores the surface of solids, these data do not reflect bulk degradability of the copolymers but, instead, their relative degradability at the molecular level. Based on a "reactive-DESI degradability scale" such as that established here for PLAGA, the proposed method offers interesting perspectives to qualify intrinsic degradability of different polyesters and evaluate their erosion susceptibility or to determine the degradability of those polymers known to degrade via erosion only.
引用
收藏
页码:12041 / 12048
页数:8
相关论文
共 51 条
[1]   Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry with size-exclusion chromatographic fractionation for structural characterization of synthetic aliphatic copolyesters [J].
Adamus, G ;
Rizzarelli, P ;
Montaudo, MS ;
Kowalczuk, M ;
Montaudo, G .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (05) :804-814
[2]   Molecular level structure of novel synthetic analogues of aliphatic biopolyesters as revealed by multistage mass spectrometry [J].
Adamus, Grazyna ;
Kwiecien, Iwona ;
Maksymiak, Magdalena ;
Balakier, Tomasz ;
Jurczak, Janusz ;
Kowalczuk, Marek .
ANALYTICA CHIMICA ACTA, 2014, 808 :104-114
[3]   Degradation profile and preliminary clinical testing of a resorbable device for ligation of blood vessels [J].
Aminlashgari, Nina ;
Hoglund, Odd V. ;
Borg, Niklas ;
Hakkarainen, Minna .
ACTA BIOMATERIALIA, 2013, 9 (06) :6898-6904
[4]   Polylactide Stereocomplexation Leads to Higher Hydrolytic Stability but More Acidic Hydrolysis Product Pattern [J].
Andersson, Sofia Regnell ;
Hakkarainen, Minna ;
Inkinen, Saara ;
Sodergard, Anders ;
Albertsson, Ann-Christine .
BIOMACROMOLECULES, 2010, 11 (04) :1067-1073
[5]  
[Anonymous], 2016, CRC Handbook of Chemistry and Physics, V97th, DOI [10.1201/9781315380476, DOI 10.1201/9781315380476]
[6]   Reactions of Microsolvated Organic Compounds at Ambient Surfaces: Droplet Velocity, Charge State, and Solvent Effects [J].
Badu-Tawiah, Abraham K. ;
Campbell, Dahlia I. ;
Cooks, R. Graham .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (06) :1077-1084
[7]   Synthesis, properties and biomedical applications of hydrolytically degradable materials based on aliphatic polyesters and polycarbonates [J].
Brannigan, Ruairi P. ;
Dove, Andrew P. .
BIOMATERIALS SCIENCE, 2017, 5 (01) :9-21
[8]   Polyester/Poly(meth)acrylate Block Copolymers by Combined Polycondensation/ATRP: Characterization and Properties [J].
Chatterjee, Uma ;
Wang, Xiaojiang ;
Jewrajka, Suresh K. ;
Soucek, Mark D. .
MACROMOLECULAR CHEMISTRY AND PHYSICS, 2011, 212 (17) :1879-1890
[9]   Time-of-flight secondary ion mass spectrometry studies of in vitro hydrolytic degradation of biodegradable polymers [J].
Chen, JX ;
Gardella, JA .
MACROMOLECULES, 1999, 32 (22) :7380-7388
[10]   Disintegration and cancer immunotherapy efficacy of a squalane-in-water delivery system emulsified by bioresorbable poly (ethylene glycol)-block-polylactide [J].
Chen, Wei-Lin ;
Liu, Shih-Jen ;
Leng, Chih-Hsiang ;
Chen, Hsin-Wei ;
Chong, Pele ;
Huang, Ming-Hsi .
BIOMATERIALS, 2014, 35 (05) :1686-1695