Intra- and inter-observer agreements in detecting peri-implant bone defects between periapical radiography and cone beam computed tomography: A clinical study

被引:6
|
作者
Zhang, Chu-Nan [1 ,2 ,3 ,4 ]
Zhu, Yu [1 ,2 ,3 ,4 ]
Fan, Lin-Feng [5 ]
Zhang, Xiao [1 ,2 ,3 ,4 ]
Jiang, Yin-Hua [6 ]
Gu, Ying-Xin [1 ,2 ,3 ,4 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Coll Stomatol, Dept Implant Dent,Sch Med, Shanghai, Peoples R China
[2] Natl Clin Res Ctr Oral Dis, Shanghai, Peoples R China
[3] Shanghai Key Lab Stomatol, Shanghai, Peoples R China
[4] Shanghai Res Inst Stomatol, Shanghai, Peoples R China
[5] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 9, Coll Stomatol, Dept Radiol,Sch Med, Shanghai, Peoples R China
[6] Wenzhou Med Univ, Lishui Peoples Hosp 6, Dept Oral & Maxillofacial Implantol, Lishui, Peoples R China
关键词
Cone beam computed tomography; Dental implants; Periapical radiography; Peri-implant bone defect; FIELD-OF-VIEW; DENTAL IMPLANTS; ACCURACY; FENESTRATION; LEVEL;
D O I
10.1016/j.jds.2020.10.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background/purpose: Information regarding agreements between periapical radio-graph (PA) and cone beam computed tomography (CBCT) in detecting peri-implant defect is still scarce. The aim of this clinical study was to compare agreements between PA and CBCT in detecting peri-implant bone defect. Materials and methods: This retrospective clinical study enrolled 32 patients with both PA and CBCT filmed right after implant placement. Four modalities were used for film reading: PA1 (orig-inal), PA2 (enhanced brightness/contrast), CBCT1 (selected axial and mesial-distal direction im-ages) and CBCT2 (all data with software). 2 experienced and 2 inexperienced observers scored all films. Intra-and inter-observer agreements were estimated with Cohen's kappa coefficient. Cate-gorized agreements were compared and differences among four modalities were calculated. Results: Agreements of PA were better than CBCT when detecting peri-implant bone defects in inter-observer agreements (median kappa 0.471 vs. 0.192; p = 0.016). Moreover, agreements in experienced observers were better than inexperienced observers (median kappa 0.883 vs. 0.567; p < 0.001). There was significant difference among four modalities except for experienced observer 2 (p = 0.218). Conclusion: Agreements of PA are better than CBCT when detecting peri-implant bone defects, especially for inter-observer agreements. Experienced observers are more consistent in assess-ment than inexperienced ones. & ordf; 2020 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons. org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:948 / 956
页数:9
相关论文
共 46 条
  • [21] Detection of periapical bone defects in human jaws using cone beam computed tomography and intraoral radiography
    Patel, S.
    Dawood, A.
    Mannocci, F.
    Wilson, R.
    Ford, T. Pitt
    INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (06) : 507 - 515
  • [22] Accuracy evaluation of cone beam computed tomography applied to measure peri-implant bone thickness in living patients: an ex vivo and in vivo experiment
    Yanhua Lan
    Xiaoyuan Huang
    Mingxing Fan
    Huazhen Yu
    Zhijian Xie
    Yiqun Zhou
    Clinical Oral Investigations, 2022, 26 : 6347 - 6359
  • [23] Accuracy evaluation of cone beam computed tomography applied to measure peri-implant bone thickness in living patients: an ex vivo and in vivo experiment
    Lan, Yanhua
    Huang, Xiaoyuan
    Fan, Mingxing
    Yu, Huazhen
    Xie, Zhijian
    Zhou, Yiqun
    CLINICAL ORAL INVESTIGATIONS, 2022, 26 (10) : 6347 - 6359
  • [24] Effect of Cone-Beam Computed Tomography Field of View and Acquisition Frame on the Detection of Chemically Simulated Peri-Implant Bone Loss In Vitro
    Pinheiro, Lucas Rodrigues
    Scarfe, William C.
    de Oliveira Sales, Marcelo Augusto
    Gaia, Bruno Felipe
    Gonzalez Cortes, Arthur Rodriguez
    Cavalcanti, Marcelo Gusmao
    JOURNAL OF PERIODONTOLOGY, 2015, 86 (10) : 1159 - 1165
  • [25] Comparison of the different voxel sizes in the estimation of peri-implant fenestration defects using cone beam computed tomography: an ex vivo study
    Kurt, Mehmet Hakan
    Bagis, Nilsun
    Evli, Cengiz
    Atakan, Cemal
    Orhan, Kaan
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [26] Measurement of Peri-Implant Bone Width with and without Metal Artifact Reduction Algorithm Using Two Cone-Beam Computed Tomography Software Programs
    Hedayatipanah, Morad
    Salemi, Fatemeh
    Kamyari, Naser
    Yalpanian, Ashkan
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2021, 21
  • [27] Peri-implant bone tissue assessment by comparing the outcome of intra-oral radiograph and cone beam computed tomography analyses to the histological standard
    Corpas, Livia dos Santos
    Jacobs, Reinhilde
    Quirynen, Marc
    Huang, Yan
    Naert, Ignace
    Duyck, Joke
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (05) : 492 - 499
  • [28] Evaluation of Post-implant Buccal Bone Resorption Using Cone Beam Computed Tomography: A Clinical Pilot Study
    Vera, Carolina
    De Kok, Ingeborg J.
    Chen, Wenjie
    Reside, Glenn
    Tyndall, Donald
    Cooper, Lyndon F.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (05) : 1249 - 1257
  • [29] Comparison of the different voxel sizes in the estimation of peri-implant fenestration defects using cone beam computed tomography: an ex vivo study
    Mehmet Hakan Kurt
    Nilsun Bağış
    Cengiz Evli
    Cemal Atakan
    Kaan Orhan
    International Journal of Implant Dentistry, 6
  • [30] Association between marginal bone loss and bone quality at dental implant sites based on evidence from cone beam computed tomography and periapical radiographs
    Eskandarloo, Amir
    Arabi, Reza
    Bidgoli, Mohsen
    Yousefi, Faezeh
    Poorolajal, Jalal
    CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (01) : 36 - 41