An innovative immunosensor for detection of tumor suppressor protein p53 in unprocessed human plasma and cancer cell lysates

被引:47
作者
Hasanzadeh, Mohammad [1 ]
Baghban, Hossein Navay [2 ]
Mokhtarzadeh, Ahad [3 ]
Shadjou, Nasrin [4 ,5 ]
Mahboob, Soltanali [6 ]
机构
[1] Tabriz Univ Med Sci, Drug Appl Res Ctr, Tabriz 51664, Iran
[2] Tabriz Univ Med Sci, Pharmaceut Anal Res Ctr, Tabriz, Iran
[3] Tabriz Univ Med Sci, Immunol Res Ctr, Tabriz, Iran
[4] Uremia Univ, Nano Technol Res Ctr, Dept Nanochem, Uremia 57154, Iran
[5] Uremia Univ, Fac Sci, Dept Nano Technol, Uremia 57154, Iran
[6] Higher Educ Inst Rab Rashid, Dept Biochem, Tabriz, Iran
关键词
Electrochemical immunosensor; Biomarker; Gold nanoparticles; Poly amino acid; p53 Tumor protein; Signal amplification; SIGNAL-AMPLIFICATION ELEMENTS; ASSEMBLED GOLD ELECTRODE; GLASSY-CARBON ELECTRODE; ELECTROCHEMICAL QUANTIFICATION; ASCORBIC-ACID; WHOLE-BLOOD; NANOMATERIALS; FILM; NANOPARTICLES; IMMUNOASSAY;
D O I
10.1016/j.ijbiomac.2017.07.165
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
An innovative mediator-free electrochemical immunosensor for quantitation of p53 tumor suppressor protein based on signal amplification strategy was fabricated. In this work, biotin conjugated p53 antibody (anti-p53) was immobilized onto a green and biocompatible nanocomposite containing poly L-cysteine (P-Cys) as conductive matrix and 3D gold nanoparticles (GNPs) as signal amplification element. Therefore, a novel nanocomposite film based on P-Cys and GNPs was exploited to develop a highly sensitive immunosensor for detection of p53 protein. Importantly, GNPs prepared by sonoelectrodeposition method which lead to compact morphology. Fully electrochemical methodology was used to prepare a new transducer on a gold surface which provided a high surface area to immobilize a high amount of the anti-p53. The surface morphology of electrode was characterized by high-resolution field emission scanning electron microscope (FE-SEM) and energy dispersive spectroscopy (EDX). The immunosensor was employed for the detection of p53 in physiological pH using square wavvoltammetry and differential pulse voltammetry (DPVs) techniques. tinder optimized condition the calibration curve for p53 concentration by SWV and DPV was linear in 0.0369-50 pM and 0.018-2.5 pM with lower limit of quantification of 48 fM and 18 fM, respectively. The method was successfully applied assay of the p53 in unprocessed human plasma samples. Also, the method was applied to the assay of p53 in human plasma sample and normal and malignant cell line lysates such as (L929 normal cell Line from mouse C3H (L929), colon cancer cell-HCT, prostate cancer cell line PC-3, and human breast adenocarcinoma cell line-MCF7). (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:1337 / 1348
页数:12
相关论文
共 31 条
[1]   A sandwich type immunosensor for ultrasensitive electrochemical quantification of p53 protein based on gold nanoparticles/graphene oxide [J].
Afsharan, Hadi ;
Khalilzadeh, Balal ;
Tajalli, Habib ;
Mollabashi, Mahmood ;
Navaeipour, Farzaneh ;
Rashidi, Mohammad-Reza .
ELECTROCHIMICA ACTA, 2016, 188 :153-164
[2]   Magnetic particle-based immunoassay of phosphorylated p53 using protein cage templated lead phosphate and carbon nanospheres for signal amplification [J].
Chen, Aiqiong ;
Bao, Yuanwu ;
Ge, Xiaoxiao ;
Shin, Yongsoon ;
Du, Dan ;
Lin, Yuehe .
RSC ADVANCES, 2012, 2 (29) :11029-11034
[3]   Multiplexed Electrochemical Immunoassay of Phosphorylated Proteins Based on Enzyme-Functionalized Gold Nanorod Labels and Electric Field-Driven Acceleration [J].
Du, Dan ;
Wang, Jun ;
Lu, Donglai ;
Dohnalkova, Alice ;
Lin, Yuehe .
ANALYTICAL CHEMISTRY, 2011, 83 (17) :6580-6585
[4]   Functionalized Graphene Oxide as a Nanocarrier in a Multienzyme Labeling Amplification Strategy for Ultrasensitive Electrochemical Immunoassay of Phosphorylated p53 (S392) [J].
Du, Dan ;
Wang, Limin ;
Shao, Yuyan ;
Wang, Jun ;
Engelhard, Mark H. ;
Lin, Yuehe .
ANALYTICAL CHEMISTRY, 2011, 83 (03) :746-752
[5]   β-Cyclodextrin-Functionalized Gold Nanoparticles/Poly(L-cysteine) Modified Glassy Carbon Electrode for Sensitive Determination of Metronidazole [J].
Gu, Yue ;
Liu, Weilu ;
Chen, Ruixue ;
Zhang, Li ;
Zhang, Zhiquan .
ELECTROANALYSIS, 2013, 25 (05) :1209-1216
[6]  
Hasanzadeh M, 2017, REV MICROCHIMICA ACT, V184, P389
[7]   Proline dehydrogenase-entrapped mesoporous magnetic silica nanomaterial for electrochemical biosensing of L-proline in biological fluids [J].
Hasanzadeh, Mohammad ;
Nahar, Arezoo Saadati ;
Hassanpour, Soodabeh ;
Shadjou, Nasrin ;
Molchtarzadeh, Ahad ;
Mohammadi, Jalal .
ENZYME AND MICROBIAL TECHNOLOGY, 2017, 105 :64-76
[8]   Early stage diagnosis of programmed cell death (apoptosis) using electroanalysis: Nanomaterial and methods overview [J].
Hasanzadeh, Mohammad ;
Shadjou, Nasrin ;
de la Guardia, Miguel .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 93 :199-211
[9]   Early stage screening of breast cancer using electrochemical biomarker detection [J].
Hasanzadeh, Mohammad ;
Shadjou, Nasrin ;
de la Guardia, Miguel .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 91 :67-76
[10]   (Nano)-materials and methods of signal enhancement for genosensing of p53 tumor suppressor protein: Novel research overview [J].
Hasanzadeh, Mohammad ;
Shadjou, Nasrin .
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 76 :1424-1439