Computational hip joint simulator for wear and heat generation

被引:75
作者
Fialho, Jorge C.
Fernandes, Paulo R. [1 ]
Eca, Luis
Folgado, Joao
机构
[1] IDMEC IST, Lisbon, Portugal
[2] DEM IST, Lisbon, Portugal
关键词
hip joint; acetabular wear; heat generation; contact; finite elements;
D O I
10.1016/j.jbiomech.2006.12.005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper presents a computational simulator for the hip to compute the wear and heat generation on artificial joints. The friction produced on artificial hip joints originates wear rates that can lead to failure of the implant. Furthermore, the frictional heating can increase the wear. The developed computational model calculates the wear in the joint and the temperature in the surrounding zone, allowing the use of different combinations of joint materials, daily activities and different individuals. The pressure distribution on the joint bearing surfaces is obtained with the solution of a contact model. The heat generation by friction and the volumetric wear is computed from the pressure distribution and the sliding distance. The temperature is obtained from the solution of a transient heat conduction problem that includes the time-dependent heat generated by friction. The contact and heat conduction problems are solved numerically with the Finite Element Method. The developed computational model performs a full simulation of the acetabular bearing surface behaviour, which is useful for acetabular cup design and material selection. The results obtained by the present model agree with experimental and clinical data, as well as other numerical studies. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2358 / 2366
页数:9
相关论文
共 16 条
[1]  
*ANSYS INC, 2003, THEOR REF MAN
[2]   CONTACT AND RUBBING OF FLAT SURFACES [J].
ARCHARD, JF .
JOURNAL OF APPLIED PHYSICS, 1953, 24 (08) :981-988
[3]   Frictional heating of total hip implants. Part 1. measurements in patients [J].
Bergmann, G ;
Graichen, F ;
Rohlmann, A ;
Verdonschot, N ;
van Lenthe, GH .
JOURNAL OF BIOMECHANICS, 2001, 34 (04) :421-428
[4]   Frictional heating of total hip implants. Part 2: finite element study [J].
Bergmann, G ;
Graichen, F ;
Rohlmann, A ;
Verdonschot, N ;
van Lenthe, GH .
JOURNAL OF BIOMECHANICS, 2001, 34 (04) :429-435
[5]   HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[6]   Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[7]   MEASUREMENTS OF THERMAL-PROPERTIES FOR HUMAN FEMORA [J].
BIYIKLI, S ;
MODEST, MF ;
TARR, R .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1986, 20 (09) :1335-1345
[8]  
BRANDFONBRENER AG, 1994, MED PROBL PERFORM AR, V9, P1
[9]   Local head roughening as a factor contributing to variability of total hip wear: A finite element analysis [J].
Brown, TD ;
Stewart, KJ ;
Nieman, JC ;
Pedersen, DR ;
Callaghan, JJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (06) :691-698
[10]  
DAVIDSON JA, 1988, J BIOMED MATER RES-A, V22, P69