An optical coherence photoacoustic microscopy system using a fiber optic sensor

被引:11
|
作者
Deng, Shiyu [1 ]
Haindl, Richard [1 ]
Zhang, Edward [2 ,3 ]
Beard, Paul [2 ,3 ]
Scheuringer, Eva [4 ]
Sturtzel, Caterina [4 ]
Li, Qian [1 ]
Deloria, Abigail J. [1 ]
Sattmann, Harald [1 ]
Leitgeb, Rainer A. [1 ]
Yuan, Yi [5 ]
Schmetterer, Leopold [1 ,6 ,7 ,8 ,9 ,10 ,11 ]
Pramanik, Manojit [8 ]
Distel, Martin [4 ]
Drexler, Wolfgang [4 ]
Liu, Mengyang [4 ]
机构
[1] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Wahringer Gurtel 18-20,AKH 4L, A-1090 Vienna, Austria
[2] UCL, Dept Med Phys & Biomed Engn, Gower St, London WC1E 6BT, England
[3] UCL, Wellcome EPSRC Ctr Intervent & Surg Sci, Gower St, London WC1E 6BT, England
[4] St Anna Childrens Canc Res Inst, Innovat Canc Models, Zimmermannpl 10, A-1090 Vienna, Austria
[5] Yanshan Univ, Inst Elect Engn, Qinhuangdao 066004, Hebei, Peoples R China
[6] Med Univ Vienna, Dept Clin Pharmacol, Wahringer Gurtel 18-20,Floor 6, A-1090 Vienna, Austria
[7] Singapore Eye Res Inst, Acad Bldg,20 Coll Rd,Discovery Tower,Level 6, Singapore 169856, Singapore
[8] Nanyang Technol Univ, Sch Chem & Biomed Engn, 62 Nanyang Drive, Singapore 637459, Singapore
[9] SERI NTU Adv Ocular Engn STANCE Lab, Singapore, Singapore
[10] Duke NUS Med Sch, Ophthalmol & Visual Sci Acad Clin Program, 8 Coll Rd, Singapore 169857, Singapore
[11] Inst Mol & Clin Ophthalmol Basel, Mittlere Str 91, CH-4031 Basel, Switzerland
基金
欧盟地平线“2020”; 欧洲研究理事会;
关键词
IN-VIVO; TOMOGRAPHY; ZEBRAFISH; MODEL;
D O I
10.1063/5.0059351
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this work, a novel fiber optic sensor based on Fabry-Perot interferometry is adopted in an optical coherence photoacoustic microscopy (OC-PAM) system to enable high-resolution in vivo imaging. The complete OC-PAM system is characterized using the fiber optic sensor for photoacoustic measurement. After characterization, the performance of the system is evaluated by imaging zebrafish larvae in vivo. With a lateral resolution of 3.4 mu m and an axial resolution of 3.7 mu m in air, the optical coherence microscopy subsystem visualizes the anatomy of the zebrafish larvae. The photoacoustic microscopy subsystem reveals the vasculature of the zebrafish larvae with a lateral resolution of 1.9 mu m and an axial resolution of 37.3 mu m. As the two modalities share the same sample arm, we obtain inherently co-registered morphological and vascular images. This OC-PAM system provides comprehensive information on the anatomy and vasculature of the zebrafish larvae. Featuring compactness, broad detection bandwidth, and wide detection angle, the fiber optic sensor enables a large field of view with a static sensor position. We verified the feasibility of the fiber optic sensor for dual-modality in vivo imaging. The OC-PAM system, as a non-invasive imaging method, demonstrates its superiority in the investigation of zebrafish larvae, an animal model with increasing significance in developmental biology and disease research. This technique can also be applied for functional as well as longitudinal studies in the future.& nbsp; (C) 2021 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution (CC BY) license(http://creativecommons.org/licenses/by/4.0/).</p>
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Dual modality reflection mode optical coherence and photoacoustic microscopy using an akinetic sensor
    Haindl, Richard
    Preisser, Stefan
    Andreana, Marco
    Rohringer, Wolfgang
    Sturtzel, Caterina
    Distel, Martin
    Chen, Zhe
    Rank, Elisabet
    Fischer, Balthasar
    Drexler, Wolfgang
    Liu, Mengyang
    OPTICS LETTERS, 2017, 42 (21) : 4319 - 4322
  • [2] In vivo imaging of microcirculation using integrated photoacoustic and optical coherence microscopy
    Li, Li
    Maslov, Konstantin I.
    Ku, Geng
    Wang, Lihong V.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2009, 2009, 7177
  • [3] Optical coherence photoacoustic microscopy for in vivo multimodal retinal imaging
    Liu, Xiaojing
    Liu, Tan
    Wen, Rong
    Li, Yiwen
    Puliafito, Carmen A.
    Zhang, Hao F.
    Jiao, Shuliang
    OPTICS LETTERS, 2015, 40 (07) : 1370 - 1373
  • [4] Miniaturized fiber optic ultrasound sensor with multiplexing for photoacoustic imaging
    Yang, Liuyang
    Xu, Dongchen
    Chen, Geng
    Wang, Anqi
    Li, Liangye
    Sun, Qizhen
    PHOTOACOUSTICS, 2022, 28
  • [5] Dual-Polarized Fiber Laser Sensor for Photoacoustic Microscopy
    Lin, Xiangwei
    Liang, Yizhi
    Jin, Long
    Wang, Lidai
    SENSORS, 2019, 19 (21)
  • [6] Fast subcellular optical coherence photoacoustic microscopy for pigment cell imaging
    Li, Lin
    Dai, Cuixia
    Li, Qian
    Zhao, Qingliang
    Jiang, Xiaoyun
    Chai, Xinyu
    Zhou, Chuanqing
    OPTICS LETTERS, 2015, 40 (19) : 4448 - 4451
  • [7] Imaging Dynamic Processes Using Fiber Laser Optical-Resolution Photoacoustic Microscopy
    Shi, Wei
    Shao, Peng
    Hajireza, Parsin
    Forbrich, Alexander
    Zemp, Roger J.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2012, 2012, 8223
  • [8] Integrated photoacoustic microscopy, optical coherence tomography, and fluorescence microscopy for multimodal chorioretinal imaging
    Tian, Chao
    Zhang, Wei
    Van Phuc Nguyen
    Huang, Ziyi
    Wang, Xueding
    Paulus, Yannis M.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2018, 2018, 10494
  • [9] Functional optical coherence tomography and photoacoustic microscopy imaging for zebrafish larvae
    Haindl, Richard
    Deloria, Abigail J.
    Sturtzel, Caterina
    Sattmann, Harald
    Rohringer, Wolfgang
    Fischer, Balthasar
    Andreana, Marco
    Unterhuber, Angelika
    Schwerte, Thorsten
    Distel, Martin
    Drexler, Wolfgang
    Leitgeb, Rainer
    Liu, Mengyang
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (04) : 2137 - 2151
  • [10] Multiview optical resolution photoacoustic microscopy
    Zhu, Liren
    Li, Lei
    Gao, Liang
    Wang, Lihong V.
    OPTICA, 2014, 1 (04): : 217 - 222