A consensus statement of the society of thoracic radiology - Screening for lung cancer with helical computed tomography

被引:86
|
作者
Aberle, DR [1 ]
Gamsu, G [1 ]
Henschke, CI [1 ]
Naidich, DP [1 ]
Swensen, SJ [1 ]
机构
[1] Cornell Univ, Med Ctr, New York Hosp, Dept Radiol, New York, NY 10021 USA
关键词
lung cancer screening; low dose CT; lung nodules; early detection;
D O I
10.1097/00005382-200101000-00010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This consensus statement by the Society of Thoracic Radiology is a summary of the current understanding of low dose computed tomography (CT) for screening for lung cancer. Lung cancer is the most common fatal malignancy in the industrialized world. Unlike the next three most common cancers, screening for lung cancer is not currently recommended by cancer organizations. Improvements in CT technology make lung screening feasible. Early prevalence data indicate that about two-thirds of lung cancers that are detected by CT screening are at an early stage. Other data support the postulate that patients with lung cancers detected at this early stage have better rates of survival. Whether this will translate into an improved disease specific mortality is yet to be demonstrated. The suggested technical protocols, selection criteria, and method of handling the numerous benign nodules that are detected are discussed. It is the consensus of this committee that mass screening for lung cancer with CT is not currently advocated. Suitable subjects who wish to participate should be encouraged to do so in controlled trials, so that the value of CT screening can be ascertained as soon as possible.
引用
收藏
页码:65 / 68
页数:4
相关论文
共 50 条
  • [21] Low-dose computed-tomography lung cancer screening : the first European recommendations from the European Society of Radiology and European Respiratory Society
    Adamek, Mariusz
    Szablowska-Siwik, Sylwia
    Peled, Nir
    Rzyman, Witold
    Grodzki, Tomasz
    Czyzewski, Damian
    POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ-POLISH ARCHIVES OF INTERNAL MEDICINE, 2015, 125 (09): : 607 - 609
  • [22] Use of multidetector computed tomography for the assessment of acute chest pain: a consensus statement of the North American Society of Cardiac Imaging and the European Society of Cardiac Radiology
    Arthur E. Stillman
    Matthijs Oudkerk
    Margaret Ackerman
    Christoph R. Becker
    Pawel E. Buszman
    Pim J. de Feyter
    Udo Hoffmann
    Matthew T. Keadey
    Riccardo Marano
    Martin J. Lipton
    Gilbert L. Raff
    Gautham P. Reddy
    Michael R. Rees
    Geoffrey D. Rubin
    U. Joseph Schoepf
    Giuseppe Tarulli
    Edwin J. R. van Beek
    Lewis Wexler
    Charles S. White
    European Radiology, 2007, 17 : 2196 - 2207
  • [23] Use of multidetector computed tomography for the assessment of acute chest pain: a consensus statement of the North American Society of Cardiac Imaging and the European Society of Cardiac Radiology
    Stillman, Arthur E.
    Oudkerk, Matthijs
    Ackerman, Margaret
    Becker, Christoph R.
    Buszman, Pawel E.
    de Feyter, Pim J.
    Hoffmann, Udo
    Keadey, Matthew T.
    Marano, Riccardo
    Lipton, Martin J.
    Raff, Gilbert L.
    Reddy, Gautham P.
    Rees, Michael R.
    Rubin, Geoffrey D.
    Schoepf, U. Joseph
    Tarulli, Giuseppe
    van Beek, Edwin J. R.
    Wexler, Lewis
    White, Charles S.
    EUROPEAN RADIOLOGY, 2007, 17 (08) : 2196 - 2207
  • [24] Screening for lung cancer with low-dose helical computed tomography: Anti-lung cancer association project
    Sobue, T
    Moriyama, N
    Kaneko, M
    Kusumoto, M
    Kobayashi, T
    Tsuchiya, R
    Kakinuma, R
    Ohmatsu, H
    Nagai, K
    Nishiyama, H
    Matsui, E
    Eguchi, K
    JOURNAL OF CLINICAL ONCOLOGY, 2002, 20 (04) : 911 - 920
  • [25] Use of multidetector computed tomography for the assessment of acute chest pain: a consensus statement of the North American Society of Cardiac Imaging and the European Society of Cardiac Radiology
    Stillman, Arthur E.
    Oudkerk, Matthijs
    Ackerman, Margaret
    Becker, Christoph R.
    Buszman, Pawel E.
    de Feyter, Pim J.
    Hoffmann, Udo
    Keadey, Matthew T.
    Marano, Riccardo
    Lipton, Martin J.
    Raff, Gilbert L.
    Reddy, Gautham P.
    Rees, Michael R.
    Rubin, Geoffrey D.
    Schoepf, U. Joseph
    Tarulli, Giuseppe
    van Beek, Edwin J. R.
    Wexler, Lewis
    White, Charles S.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2007, 23 (04): : 415 - 427
  • [26] Computed Tomography Screening for Lung Cancer RESPONSE
    Henschke, Claudia I.
    Yip, Rowena
    Yankelevitz, David F.
    Smith, James P.
    ANNALS OF INTERNAL MEDICINE, 2013, 159 (02) : 156 - 157
  • [27] Computed tomography screening and lung cancer outcomes
    Bach, Peter B.
    Jett, James R.
    Pastorino, Ugo
    Tockman, Melvyn S.
    Swensen, Stephen J.
    Begg, Colin B.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 297 (09): : 953 - 961
  • [28] Computed tomography questioned for lung cancer screening
    不详
    PHOTONICS SPECTRA, 2003, 37 (03) : 42 - 42
  • [29] Computed tomography screening for lung cancer - Reply
    Bach, Peter B.
    Jett, James R.
    Pastorino, Ugo
    Tockman, Melvyn S.
    Swensen, Stephen J.
    Begg, Colin B.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (05): : 515 - 516
  • [30] Spiral Computed Tomography for Lung Cancer Screening
    Cabanes Domenech, Anna
    REVISTA ESPANOLA DE SALUD PUBLICA, 2010, 84 (06): : 687 - 689