Non-invasive Assessment of in Vivo Auricular Cartilage by Ultra-short Echo Time (UTE) T2* Mapping

被引:0
|
作者
Li, Xue [1 ]
Zhao, Cheng [1 ]
Zhang, Weiwei [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Inst Basic Med Sci, Beijing, Peoples R China
关键词
Auricular cartilage; Non-invasive assessment; Ultra-short echo time T-2*; Component analysis;
D O I
10.1007/978-3-030-32254-0_11
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this paper, Ultra-short Echo Time (UTE) T-2* mapping is proposed to non-invasively evaluate auricular cartilages from volunteers and donated bodies. The mono- and bi-exponential models were used for mono- and bi-component analysis (short component T-2* and long component T-2*) respectively. The external ears were manually segmented from images and then reconstructed into 3D T-2* mappings. In the monocomponent analysis, the mean T-2* value for 3 volunteers was 34.987 +/- 2.266 ms. As for results from the bi-component analysis, the mean values for 3 volunteers were 8.992 +/- 0.466 ms and 53.648 +/- 1.961 ms for short component T-2* and long component T-2* respectively, with the ratio of bound water to free water of 0.464 +/- 0.020. The bi-exponential fitting model performed better than the mono-exponential fitting model on the curve fitting in volunteers, with R-2[bi] = 0.999 +/- 0.131 vs. R-2 [mono] = 0.972 +/- 0.144. According to the bi-component analysis from donated specimens of auricular cartilage, the ratio of bound water to free water was 0.023 +/- 0.018, which was significantly different from that of volunteers (p < 0.01), but the fitting curves of specimens showed similar findings with volunteers, with R-2 [bi] = 0.999 +/- 0.001 vs. R-2 [mono] = 0.903 +/- 0.005. Our preliminary results demonstrated that the proposed UTE T-2* apping is a feasible non-invasive means for evaluating the development of auricular cartilage scaffold with bio-inks in reconstructive surgery using 3D bioprinting technique.
引用
收藏
页码:92 / 100
页数:9
相关论文
共 50 条
  • [41] Multi-component T2*relaxation modelling in human Achilles tendon: Quantifying chemical shift information in ultra-short echo time imaging
    Anjum, Muhammad A. R.
    Gonzalez, Felix M.
    Swain, Anshuman
    Leisen, Johannes
    Hosseini, Zahra
    Singer, Adam
    Umpierrez, Monica
    Reiter, David A.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (01) : 415 - 428
  • [42] Ultrashort echo time Cones double echo steady state (UTE-Cones-DESS) for rapid morphological imaging of short T2 tissues
    Jang, Hyungseok
    Ma, Yajun
    Carl, Michael
    Jerban, Saeed
    Chang, Eric Y.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (02) : 881 - 892
  • [43] Feasibility of Ultrashort Echo Time T2* Mapping in Comparison With T2 Mapping for Quantitative Evaluation of Meniscal Degeneration
    Ryu, Jeongah
    Lee, Sang Hoon
    Choi, Soo Yeon
    Shin, Myung Jin
    Lee, Min Hee
    Chung, Hye Won
    INVESTIGATIVE MAGNETIC RESONANCE IMAGING, 2023, 27 (01) : 49 - 55
  • [44] Cardiac 4D phase-contrast CMR at 9.4 T using self-gated ultra-short echo time (UTE) imaging
    Kraemer, M.
    Motaal, A. G.
    Herrmann, K-H.
    Loeffler, B.
    Reichenbach, J. R.
    Strijkers, G. J.
    Hoerr, V.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
  • [45] Cardiac 4D phase-contrast CMR at 9.4 T using self-gated ultra-short echo time (UTE) imaging
    M. Krämer
    A. G. Motaal
    K-H. Herrmann
    B. Löffler
    J. R. Reichenbach
    G. J. Strijkers
    V. Hoerr
    Journal of Cardiovascular Magnetic Resonance, 19
  • [46] T2 Mapping of Cartilage with Triple-Echo Steady State MR Sequence
    Juras, V.
    Bohndorf, K.
    Heule, R.
    Kronnerwetter, C.
    Szomolanyi, P.
    Bieri, O.
    Frollo, I.
    Trattnig, S.
    2017 11TH INTERNATIONAL CONFERENCE ON MEASUREMENT, 2017, : 189 - 192
  • [47] Non-invasive and in vivo assessment of osteoarthritic articular cartilage: a review on MRI investigations
    Ahmad Fadzil Mohd Hani
    Dileep Kumar
    Aamir Saeed Malik
    Raja Mohd Kamil Raja Ahmad
    Ruslan Razak
    Azman Kiflie
    Rheumatology International, 2015, 35 : 1 - 16
  • [48] Non-invasive and in vivo assessment of osteoarthritic articular cartilage: a review on MRI investigations
    Hani, Ahmad Fadzil Mohd
    Kumar, Dileep
    Malik, Aamir Saeed
    Ahmad, Raja Mohd Kamil Raja
    Razak, Ruslan
    Kiflie, Azman
    RHEUMATOLOGY INTERNATIONAL, 2015, 35 (01) : 1 - 16
  • [49] A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage
    Juras, Vladimir
    Bohndorf, Klaus
    Heule, Rahel
    Kronnerwetter, Claudia
    Szomolanyi, Pavol
    Hager, Benedikt
    Bieri, Oliver
    Zbyn, Stefan
    Trattnig, Siegfried
    EUROPEAN RADIOLOGY, 2016, 26 (06) : 1905 - 1912
  • [50] A comparison of multi-echo spin-echo and triple-echo steady-state T2 mapping for in vivo evaluation of articular cartilage
    Vladimir Juras
    Klaus Bohndorf
    Rahel Heule
    Claudia Kronnerwetter
    Pavol Szomolanyi
    Benedikt Hager
    Oliver Bieri
    Stefan Zbyn
    Siegfried Trattnig
    European Radiology, 2016, 26 : 1905 - 1912