Non-invasive Assessment of in Vivo Auricular Cartilage by Ultra-short Echo Time (UTE) T2* Mapping

被引:0
|
作者
Li, Xue [1 ]
Zhao, Cheng [1 ]
Zhang, Weiwei [1 ]
机构
[1] Chinese Acad Med Sci & Peking Union Med Coll, Inst Basic Med Sci, Beijing, Peoples R China
关键词
Auricular cartilage; Non-invasive assessment; Ultra-short echo time T-2*; Component analysis;
D O I
10.1007/978-3-030-32254-0_11
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this paper, Ultra-short Echo Time (UTE) T-2* mapping is proposed to non-invasively evaluate auricular cartilages from volunteers and donated bodies. The mono- and bi-exponential models were used for mono- and bi-component analysis (short component T-2* and long component T-2*) respectively. The external ears were manually segmented from images and then reconstructed into 3D T-2* mappings. In the monocomponent analysis, the mean T-2* value for 3 volunteers was 34.987 +/- 2.266 ms. As for results from the bi-component analysis, the mean values for 3 volunteers were 8.992 +/- 0.466 ms and 53.648 +/- 1.961 ms for short component T-2* and long component T-2* respectively, with the ratio of bound water to free water of 0.464 +/- 0.020. The bi-exponential fitting model performed better than the mono-exponential fitting model on the curve fitting in volunteers, with R-2[bi] = 0.999 +/- 0.131 vs. R-2 [mono] = 0.972 +/- 0.144. According to the bi-component analysis from donated specimens of auricular cartilage, the ratio of bound water to free water was 0.023 +/- 0.018, which was significantly different from that of volunteers (p < 0.01), but the fitting curves of specimens showed similar findings with volunteers, with R-2 [bi] = 0.999 +/- 0.001 vs. R-2 [mono] = 0.903 +/- 0.005. Our preliminary results demonstrated that the proposed UTE T-2* apping is a feasible non-invasive means for evaluating the development of auricular cartilage scaffold with bio-inks in reconstructive surgery using 3D bioprinting technique.
引用
收藏
页码:92 / 100
页数:9
相关论文
共 50 条
  • [31] T2*WEIGHTED MRI: A NON-INVASIVE METHOD TO ASSESS PLACENTAL FUNCTION IN VIVO
    Sorensen, Anne
    PLACENTA, 2021, 112 : E17 - E17
  • [32] T2 mapping for quantitative assessment of ankle cartilage of weightlifters
    Weibiao Wu
    Zhuanzhuan Kang
    Di Mu
    Huiyu Zhao
    Feng Yang
    Scientific Reports, 13
  • [33] T2 mapping for quantitative assessment of ankle cartilage of weightlifters
    Wu, Weibiao
    Kang, Zhuanzhuan
    Mu, Di
    Zhao, Huiyu
    Yang, Feng
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [34] Ex vivo imaging of subacute myocardial ischemia with ultra-short echo time 3-D quantitative T1-mapping MRI in mice
    Raty, I.
    Paajanen, A.
    Nissi, M. J.
    Ruotsalainen, A-K.
    Laidinen, S.
    Yla-Herttuala, S.
    Yla-Herttuala, E.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [35] Quantification Of Neonatal Lung Parenchymal Density Via Ultra-Short Echo-Time (ute) Magnetic Resonance Imaging (mri)
    Higano, N. S.
    Walkup, L. L.
    Hahn, A.
    Thomen, R.
    Merhar, S.
    Kingma, P. S.
    Tkach, J. A.
    Fain, S.
    Woods, J. C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [36] T2 Relaxation Time Mapping of the Cartilage Cap of Osteochondromas
    Kim, Hee Kyung
    Horn, Paul
    Dardzinski, Bernard J.
    Kim, Dong Hoon
    Laor, Tal
    KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (01) : 159 - 165
  • [37] A black-blood ultra-short echo time (UTE) sequence for 3D isotropic resolution imaging of the lungs
    Delacoste, Jean
    Feliciano, Helene
    Yerly, Jerome
    Dunet, Vincent
    Beigelman-Aubry, Catherine
    Ginami, Giulia
    van Heeswijk, Ruud B.
    Piccini, Davide
    Stuber, Matthias
    Sauty, Alain
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (06) : 3808 - 3818
  • [38] Magnetic resonance imaging of short T2 relaxation components in tissue using ultrashort echo time (UTE) pulse sequences
    Bydder, M
    Znamirowski, RM
    Bydder, GM
    CURRENT MEDICAL IMAGING REVIEWS, 2006, 2 (01) : 79 - 90
  • [39] Weighted subtraction in 3D ultrashort echo time (UTE) imaging for visualization of short T2 tissues of the knee
    Lee, Young Han
    Kim, Sungjun
    Song, Ho-Taek
    Kim, InSeong
    Suh, Jin-Suck
    ACTA RADIOLOGICA, 2014, 55 (04) : 454 - 461
  • [40] Overview of Short and Ultrashort T-2/T-2* Echo Time (UTE) Imaging
    Young, Ian
    EMAGRES, 2012, 1 (04): : 747 - 755