Optimization Analysis on Electrical Insulation Performance of ITER Axial Composite Insulation Break

被引:0
作者
Qiu, Yun-Lai [1 ]
Yang, Chang-Chun [1 ]
机构
[1] Jiujiang Univ, Coll Elect Engn, Jiujiang 332005, Peoples R China
来源
PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON MATERIAL SCIENCE AND APPLICATIONS (ICMSA 2015) | 2015年 / 3卷
关键词
Optimization Analysis; Electrical Insulation Performance; ITER; Insulation Break (IB);
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Optimization analysis on Electrical Insulation Performance was conducted using ANSYS soft for ITER axial insulation breaks. The optimal parameters of Li, and R have been achieved. The analysis results showed that the value of the maximal electric field in GFRP section is 3.396kV/mm. This position locates on the arc top of the interface between SS electrode and GFRP section. The field strength is respectively less than allowable 4kV/mm and 2kV/mm in GFRP and in air to meet the technical requirements of ITER axial insulation breaks.
引用
收藏
页码:819 / 823
页数:5
相关论文
共 6 条
  • [1] [吴诚 Wu Cheng], 2011, [低温与超导, Cryogenics and Superconductivity], V39, P12
  • [2] [杨长春 Yang Changchun], 2011, [低温与超导, Cryogenics and Superconductivity], V39, P07
  • [3] [杨长春 Yang Changchun], 2010, [核聚变与等离子体物理, Nuclear Fusion and Plasma Physics], V30, P272
  • [4] [杨长春 Yang Changchun], 2009, [低温工程, Cryogenics], P23
  • [5] [张远斌 ZHANG Yuanbin], 2007, [原子能科学技术, Atomic Energy Science and Technology], V41, P752
  • [6] [张远斌 ZHANG Yuanbin], 2007, [核聚变与等离子体物理, Nuclear Fusion and Plasma Physics], V27, P137