Mechanical torque measurement for in vivo quantification of bone strength in the proximal femur

被引:6
作者
Mueller, Marc Andreas [1 ]
Hengg, Clemens [2 ]
Hirschmann, Michael [3 ]
Schmid, Denise [4 ]
Sprecher, Christoph [5 ]
Audige, Laurent [4 ]
Suhm, Norbert [1 ]
机构
[1] Univ Basel Hosp, Dept Orthoped Surg & Traumatol, CH-4031 Basel, Switzerland
[2] Univ Innsbruck Hosp, Dept Trauma Surg & Sports Med, Innsbruck, Austria
[3] Cantonal Hosp Bruderholz, Dept Orthoped Surg, Bruderholz, Switzerland
[4] AO Fdn, AO Inst Clin Invest & Documentat, Dubendorf, Switzerland
[5] AO Fdn, AO Res Inst, Davos, Switzerland
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2012年 / 43卷 / 10期
关键词
Bone strength; In vivo mechanical measurement; Bone quality; Bone mineral density; Densitometry; Hip fracture fixation; FEMORAL-NECK; MINERAL DENSITY; FRACTURES; DETERMINANTS; FIXATION; QUALITY; OSTEOPOROSIS; SCREW; SPINE;
D O I
10.1016/j.injury.2012.06.014
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Bone strength determines fracture risk and fixation strength of osteosynthesis implants. In vivo, bone strength is currently measured indirectly by quantifying bone mineral density (BMD) which is however only one determinant of the bone's biomechanical competence besides the bone's macro- and micro-architecture and tissue related parameters. We have developed a measurement principle (DensiProbe (TM) Hip) for direct, mechanical quantification of bone strength within the proximal femur upon hip fracture fixation. Previous cadaver tests indicated a close correlation between DensiProbe (TM) Hip measurements, 3D micro-CT analysis and biomechanical indicators of bone strength. The goal of this study was to correlate DensiProbe (TM) Hip measurements with areal bone mineral density (BMD). Methods: Forty-three hip fracture patients were included in this study. Intraoperatively, DensiProbe (TM) Hip was inserted to the subsequent hip screw tip position within the femoral head. Peak torque to breakaway of local cancellous bone was registered. Thirty-seven patients underwent areal BMD measurements of the contralateral proximal femur. Failure of fixation was assessed radio graphically 6 and 12 weeks postoperatively. Results: Peak torque and femoral neck BMD showed significant correlations (R = 0.60, P = 0.0001). In regression analysis, areal BMD explained 46% of femoral neck BMD variance in a quadratic relationship. Throughout the 12-week follow-up period, no failure of fixation was observed. Conclusions: DensiProbe (TM) Hip may capture variations of bone strength beyond areal BMD which are currently difficult to measure in vivo. A multicenter study will clarify if peak torque predicts fixation failure. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1712 / 1717
页数:6
相关论文
共 28 条
[2]   Treatment strategies for proximal femur fractures in osteoporotic patients [J].
Bonnaire, Felix ;
Zenker, Henry ;
Lill, Christoph ;
Weber, Andreas T. ;
Linke, Berend .
OSTEOPOROSIS INTERNATIONAL, 2005, 16 (Suppl 2) :S93-S102
[3]  
Bonnick Sydney Lou, 2007, Curr Opin Endocrinol Diabetes Obes, V14, P451, DOI 10.1097/MED.0b013e3282f154a7
[4]  
BOSKEY AL, 1990, ORTHOP CLIN N AM, V21, P19
[5]   Quantifying the material and structural determinants of bone strength [J].
Bouxsein, Mary L. ;
Seeman, Ego .
BEST PRACTICE & RESEARCH IN CLINICAL RHEUMATOLOGY, 2009, 23 (06) :741-753
[6]   High-resolution Computed Tomography for Clinical Imaging of Bone Microarchitecture [J].
Burghardt, Andrew J. ;
Link, Thomas M. ;
Majumdar, Sharmila .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (08) :2179-2193
[7]   Microdamage and bone strength [J].
Burr, D .
OSTEOPOROSIS INTERNATIONAL, 2003, 14 (Suppl 5) :S67-S72
[8]   Clinical use of bone densitometry - Scientific review [J].
Cummings, SR ;
Bates, D ;
Black, DM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 288 (15) :1889-1897
[9]   Radiation exposure in X-ray-based imaging techniques used in osteoporosis [J].
Damilakis, John ;
Adams, Judith E. ;
Guglielmi, Giuseppe ;
Link, Thomas M. .
EUROPEAN RADIOLOGY, 2010, 20 (11) :2707-2714
[10]   Microindentation for In Vivo Measurement of Bone Tissue Mechanical Properties in Humans [J].
Diez-Perez, Adolfo ;
Guerri, Roberto ;
Nogues, Xavier ;
Caceres, Enric ;
Jesus Pena, Maria ;
Mellibovsky, Leonardo ;
Randall, Connor ;
Bridges, Daniel ;
Weaver, James C. ;
Proctor, Alexander ;
Brimer, Davis ;
Koester, Kurt J. ;
Ritchie, Robert O. ;
Hansma, Paul K. .
JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (08) :1877-1885