Imaging electric conductivity with MRI

被引:0
|
作者
Voigt, T. [1 ]
Katscher, U. [2 ]
Findeklee, C. [2 ]
Doessel, O. [1 ]
机构
[1] Univ Karlsruhe, Inst Biomed Engn, Karlsruhe, Germany
[2] Sect Med Imaging Syst, Philips Res Europe Hamburg, Hamburg, Germany
来源
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING | 2009年 / 25卷
关键词
Electric Conductivity; Magnetic Resonance Tomography; B1; mapping; IMPEDANCE TOMOGRAPHY MREIT; DIELECTRIC-PROPERTIES; MAGNETIC-RESONANCE; BIOLOGICAL TISSUES; CURRENT-DENSITY; STEADY-STATE; IN-VIVO; FREQUENCY; SYSTEM; FIELD;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The electric conductivity of human tissue could be used as an additional diagnostic parameter or might be helpful for the prediction of the local SAR during MR measurements. In this study, the approach "Electric Properties Tomography" (MR-EPT) is applied, which derives the patient's electric conductivity using a standard MR system. To this goal, the spatial transmit sensitivity distribution of the applied RF coil is measured. This sensitivity distribution represents the positive circularly polarized component of the magnetic field. It can be post-processed utilizing Faraday's and Ampere's law, yielding an estimation of the spatial distribution of the patient's electric conductivity. Thus, MR-EPT does not apply externally mounted electrodes, currents, or RF probes. In this study, phantom experiments underline the principle feasibility of MR-EPT. Furthermore, initial conductivity measurements in the brain allow distinguishing cerebro-spinal fluid from the surrounding grey and white matter.
引用
收藏
页码:42 / 45
页数:4
相关论文
共 50 条
  • [1] Electrical conductivity imaging using magnetic resonance tomography
    Katscher, Ulrich
    Voigt, Tobias
    Findeklee, Christian
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3162 - 3164
  • [2] Gradient-based electrical conductivity imaging using MR phase
    Gurler, Necip
    Ider, Yusuf Ziya
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (01) : 137 - 150
  • [3] Determination of Electric Conductivity and Local SAR Via B1 Mapping
    Katscher, Ulrich
    Voigt, Tobias
    Findeklee, Christian
    Vernickel, Peter
    Nehrke, Kay
    Doessel, Olaf
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (09) : 1365 - 1374
  • [4] Feasibility of conductivity imaging using subject eddy currents induced by switching of MRI gradients
    Oran, Omer Faruk
    Ider, Yusuf Ziya
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (05) : 1926 - 1937
  • [5] Error Analysis of Nonconstant Admittivity for MR-Based Electric Property Imaging
    Seo, Jin Keun
    Kim, Min-Oh
    Lee, Joonsung
    Choi, Narae
    Woo, Eung Je
    Kim, Hyung Joong
    Kwon, Oh In
    Kim, Dong-Hyun
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (02) : 430 - 437
  • [6] In vivo electric conductivity of cervical cancer patients based on B1+ maps at 3T MRI
    Balidemaj, E.
    de Boer, P.
    van Lier, A. L. H. M. W.
    Remis, R. F.
    Stalpers, L. J. A.
    Westerveld, G. H.
    Nederveen, A. J.
    van den Berg, C. A. T.
    Crezee, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (04): : 1596 - 1607
  • [7] Imaging Electric Properties of Biological Tissues by RF Field Mapping in MRI
    Zhang, Xiaotong
    Zhu, Shanan
    He, Bin
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (02) : 474 - 481
  • [8] Hybrid tomography for conductivity imaging
    Widlak, Thomas
    Scherzer, Otmar
    INVERSE PROBLEMS, 2012, 28 (08)
  • [9] Simultaneous Quantitative Imaging of Electrical Properties and Proton Density From B1 Maps Using MRI
    Liu, Jiaen
    Van de Moortele, Pierre-Francois
    Zhang, Xiaotong
    Wang, Yicun
    He, Bin
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (09) : 2064 - 2073
  • [10] Software Toolbox for Low-Frequency Conductivity and Current Density Imaging Using MRI
    Sajib, Saurav Z. K.
    Katoch, Nitish
    Kim, Hyung Joong
    Kwon, Oh In
    Woo, Eung Je
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (11) : 2505 - 2514