Secondary radiation in transmission-type X-ray tubes: Simulation, practical issues and solution in the context of X-ray microtomography

被引:15
|
作者
Boone, Matthieu N. [1 ]
Vlassenbroeck, Jelle [2 ]
Peetermans, Steven [3 ]
Van Loo, Denis [1 ,4 ]
Dierick, Manuel [1 ]
Van Hoorebeke, Luc [1 ]
机构
[1] Univ Ghent, Dept Phys & Astron, B-9000 Ghent, Belgium
[2] InCT, B-9052 Zwijnaarde, Belgium
[3] Paul Scherrer Inst, Neutron Imaging & Activat Grp, Villigen, Switzerland
[4] Univ Ghent, Dept Soil Management & Soil Care, B-9000 Ghent, Belgium
关键词
X-ray tube; Focal spot; Monte Carlo simulation; Secondary radiation; Off-focal radiation; BEAMnrc; EGSNRC; BEAM;
D O I
10.1016/j.nima.2011.09.046
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In laboratory-based X-ray radiography and computed tomography, the X-rays are assumed to originate from one single focal spot with a finite spot size, which is generated by focussing accelerated electrons on the target material. However, apart from this focal spot, X-rays can also be produced elsewhere in the tube system. A major contribution of this parasitic radiation originates from electrons that are backscattered from the target material, into the X-ray tube system, where they can produce so-called off-focus or secondary X-rays. This phenomenon has been widely studied for rotating anode X-ray tubes in medical imaging systems, but not for transmission-type microfocus X-ray tubes. This paper presents a study on the origin of secondary radiation in this kind of X-ray tubes, which is performed by Monte Carlo simulations and by experimental measurements. The impact of this phenomenon on the imaging process is studied, and two correction methods are proposed, both on the hardware and on the software levels. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [21] Studies on CNT Cathode Based X-ray Tubes
    Li, Xinghui
    Bai, Guodong
    Kou, Jianyong
    Li, Hanyan
    Hu, Yinfu
    Cai, Jun
    Ding, Mingqing
    Feng, Jinjun
    Liao, Fujiang
    2016 IEEE INTERNATIONAL VACUUM ELECTRONICS CONFERENCE (IVEC), 2016,
  • [22] Simulation and modeling of alignment-free field emission X-ray tubes
    Youh, Meng-Jey
    Chou, Yi-Ping
    Liu, Yih-Ming
    Ger, Ming-Der
    Hou, Kung-Hsu
    Pu, Nen-Wen
    APPLIED MATHEMATICAL MODELLING, 2015, 39 (19) : 5896 - 5906
  • [23] NEW X-RAY TUBES FOR WAFER LEVEL INSPECTION
    Bryant, Keith
    2020 INTERNATIONAL WAFER LEVEL PACKAGING CONFERENCE (IWLPC), 2020,
  • [24] Dual layer X-ray detector simulation
    Engel, Klaus Juergen
    Menser, Bernd
    Rohr, Pierre
    Ruetten, Walter
    Simon, Matthias
    Thran, Axel
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [25] Modeling and Objectification of Skiagraphy Image Quality Deterioration Caused by X-Ray Secondary Irradiation on Mobile X-Ray Device
    Fiedorova, Klara
    Augustynek, Martin
    Kubicek, Jan
    Penhaker, Marek
    Vodakova, Andrea
    Korhelik, Karol
    XV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING - MEDICON 2019, 2020, 76 : 1599 - 1608
  • [26] Monte-Carlo simulation of secondary electron emission by x-ray irradiation - an application of x-ray absorption near-edge structure (XANES)
    Iyasu, T
    Tamura, K
    Shimizu, R
    Zhang, ZM
    Koshikawa, T
    Yoshikawa, H
    Fukushima, S
    SURFACE AND INTERFACE ANALYSIS, 2004, 36 (10) : 1413 - 1416
  • [27] Radiation Charging Simulation of Alumina Ceramic Irradiated by Intense Pulsed X-ray
    Zhang, Yuqi
    Chen, Yu
    Yang, Yuxin
    Zhao, Yihan
    Zhu, Xiaofeng
    2018 IEEE 2ND INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), 2018,
  • [28] MEASUREMENT OF FOCAL SPOT SIZE IN MAMMOGRAPHY X-RAY TUBES
    LAW, J
    BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (781) : 44 - 50
  • [29] Calculation of x-ray transmission through a multileaf collimator
    Chen, Y
    Boyer, AL
    Ma, CM
    MEDICAL PHYSICS, 2000, 27 (08) : 1717 - 1726
  • [30] X-ray energy optimization in minibeam radiation therapy
    Prezado, Y.
    Thengumpallil, S.
    Renier, M.
    Bravin, A.
    MEDICAL PHYSICS, 2009, 36 (11) : 4897 - 4902