Secondary radiation in transmission-type X-ray tubes: Simulation, practical issues and solution in the context of X-ray microtomography

被引:15
|
作者
Boone, Matthieu N. [1 ]
Vlassenbroeck, Jelle [2 ]
Peetermans, Steven [3 ]
Van Loo, Denis [1 ,4 ]
Dierick, Manuel [1 ]
Van Hoorebeke, Luc [1 ]
机构
[1] Univ Ghent, Dept Phys & Astron, B-9000 Ghent, Belgium
[2] InCT, B-9052 Zwijnaarde, Belgium
[3] Paul Scherrer Inst, Neutron Imaging & Activat Grp, Villigen, Switzerland
[4] Univ Ghent, Dept Soil Management & Soil Care, B-9000 Ghent, Belgium
关键词
X-ray tube; Focal spot; Monte Carlo simulation; Secondary radiation; Off-focal radiation; BEAMnrc; EGSNRC; BEAM;
D O I
10.1016/j.nima.2011.09.046
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In laboratory-based X-ray radiography and computed tomography, the X-rays are assumed to originate from one single focal spot with a finite spot size, which is generated by focussing accelerated electrons on the target material. However, apart from this focal spot, X-rays can also be produced elsewhere in the tube system. A major contribution of this parasitic radiation originates from electrons that are backscattered from the target material, into the X-ray tube system, where they can produce so-called off-focus or secondary X-rays. This phenomenon has been widely studied for rotating anode X-ray tubes in medical imaging systems, but not for transmission-type microfocus X-ray tubes. This paper presents a study on the origin of secondary radiation in this kind of X-ray tubes, which is performed by Monte Carlo simulations and by experimental measurements. The impact of this phenomenon on the imaging process is studied, and two correction methods are proposed, both on the hardware and on the software levels. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [1] Optimization of transmission-type anode target in microfocus X-ray tube
    Zheng, Lei
    Liu, Huarong
    Sun, Buliang
    Wang, Junting
    Luo, Tingting
    Li, Yijing
    Zhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology, 2015, 35 (12): : 1443 - 1448
  • [2] Comparison of Monte Carlo tally techniques for dosimetry in a transmission-type x-ray tube
    Feng, Chen-Ju
    Lin, Chin-Hsiung
    Wu, Shu-Wei
    Luo, Shih-Yong
    Yang, Ya-Ru
    Lee, Chao-Hua
    Tseng, Shao-Chun
    Lee, Shen-Hao
    Hsu, Shih-Ming
    Wu, Chin-Hui
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (06):
  • [3] Prospects for the Use of X-Ray Tubes with a Field-Emission Cathode and a Through-Type Anode in the Range of Soft X-Ray Radiation
    M. M. Barysheva
    S. Yu. Zuev
    A. Ya. Lopatin
    V. I. Luchin
    A. E. Pestov
    N. N. Salashchenko
    N. N. Tsybin
    N. I. Chkhalo
    Technical Physics, 2020, 65 : 1726 - 1735
  • [4] Prospects for the Use of X-Ray Tubes with a Field-Emission Cathode and a Through-Type Anode in the Range of Soft X-Ray Radiation
    Barysheva, M. M.
    Zuev, S. Yu.
    Lopatin, A. Ya.
    Luchin, V. I.
    Pestov, A. E.
    Salashchenko, N. N.
    Tsybin, N. N.
    Chkhalo, N. I.
    TECHNICAL PHYSICS, 2020, 65 (11) : 1726 - 1735
  • [5] Fast method for the estimation of the absorbed dose in X-ray microtomography
    De Muynck, Amelie
    Bonte, Stijn
    Dhaene, Jelle
    Dierick, Manuel
    Bacher, Klaus
    Van Hoorebeke, Luc
    Boone, Matthieu N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 452 : 40 - 47
  • [6] X-Ray Refractive Large Aperture Rolled Prism Lenses as Condensers for X-Ray Tubes
    Vogt, H.
    Simon, M.
    Last, A.
    Marschall, F.
    Mohr, J.
    Nazmov, V.
    Eisenhower, R.
    Mettendorf, K. U.
    OPTICAL DESIGN AND ENGINEERING IV, 2011, 8167
  • [7] Polarization properties of X-ray tubes used for Imaging X-ray Polarimetry Explorer calibration
    Ratheesh, Ajay
    Rankin, John
    Costa, Enrico
    Del Monte, Ettore
    Di Marco, Alessandro
    Fabiani, Sergio
    La Monaca, Fabio
    Muleri, Fabio
    Rubini, Alda
    Soffitta, Paolo
    Baldini, Luca
    Minuti, Massimo
    Pinchera, Michele
    Sgro, Carmelo
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2023, 9 (03)
  • [8] A design of transmission-type multi-target X-ray tube based on electric field modulation
    Zhao, Lei
    Jia, Wenbao
    Jin, Limin
    Shan, Qing
    Cheng, Can
    Zhu, Hongkui
    Hei, Daqian
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (09) : 3026 - 3034
  • [9] Modification of the TASMIP x-ray spectral model for the simulation of microfocus x-ray sources
    Sisniega, A.
    Desco, M.
    Vaquero, J. J.
    MEDICAL PHYSICS, 2014, 41 (01)
  • [10] X-ray scattering in X-ray fluorescence spectra with X-ray tube excitation - Modelling, experiment, and Monte-Carlo simulation
    Hodoroaba, V. -D.
    Radtke, M.
    Vincze, L.
    Rackwitz, V.
    Reuter, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (24) : 3568 - 3575