In laboratory-based X-ray radiography and computed tomography, the X-rays are assumed to originate from one single focal spot with a finite spot size, which is generated by focussing accelerated electrons on the target material. However, apart from this focal spot, X-rays can also be produced elsewhere in the tube system. A major contribution of this parasitic radiation originates from electrons that are backscattered from the target material, into the X-ray tube system, where they can produce so-called off-focus or secondary X-rays. This phenomenon has been widely studied for rotating anode X-ray tubes in medical imaging systems, but not for transmission-type microfocus X-ray tubes. This paper presents a study on the origin of secondary radiation in this kind of X-ray tubes, which is performed by Monte Carlo simulations and by experimental measurements. The impact of this phenomenon on the imaging process is studied, and two correction methods are proposed, both on the hardware and on the software levels. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 15 条
[1]   Quantifying the effect of off-focal radiation on the output of kilovoltage x-ray systems [J].
Ali, E. S. M. ;
Rogers, D. W. O. .
MEDICAL PHYSICS, 2008, 35 (09) :4149-4160
[2]   Benchmarking EGSnrc in the kilovoltage energy range against experimental measurements of charged particle backscatter coefficients [J].
Ali, E. S. M. ;
Rogers, D. W. O. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (06) :1527-1543
[3]   Energy spectra and angular distributions of charged particles backscattered from solid targets [J].
Ali, E. S. M. ;
Rogers, D. W. O. .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2008, 41 (05)
[4]  
[Anonymous], THESIS GHENT U
[5]   SPECTRUM AND INTENSITY OF EXTRA-FOCAL (OFF-FOCUS) RADIATION [J].
BIRCH, R .
BRITISH JOURNAL OF RADIOLOGY, 1976, 49 (587) :951-955
[6]   Fast, accurate photon beam accelerator modeling using BEAMnrc: A systematic investigation of efficiency enhancing methods and cross-section data [J].
Fragoso, Margarida ;
Kawrakow, Iwan ;
Faddegon, Bruce A. ;
Solberg, Timothy D. ;
Chetty, Indrin J. .
MEDICAL PHYSICS, 2009, 36 (12) :5451-5466
[7]  
Hsieh J, 2003, COMPUT TOMOGR, DOI DOI 10.1117/3.2197756
[8]   Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version [J].
Kawrakow, I .
MEDICAL PHYSICS, 2000, 27 (03) :485-498
[9]   Efficient x-ray tube simulations [J].
Mainegra-Hing, Ernesto ;
Kawrakow, Iwan .
MEDICAL PHYSICS, 2006, 33 (08) :2683-2690
[10]   UGCT: New x-ray radiography and tomography facility [J].
Masschaele, B. C. ;
Cnudde, V. ;
Dierick, M. ;
Jacobs, P. ;
Van Hoorebeke, L. ;
Vlassenbroeck, J. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01) :266-269