Propensity-matched analysis of a side-clamp versus an anastomosis assist device in cases of isolated coronary artery bypass grafting

被引:6
作者
Saito, Aya [1 ]
Kumamaru, Hiraku [2 ]
Ono, Minoru [3 ]
Miyata, Hiroaki [4 ]
Motomura, Noboru [1 ]
机构
[1] Toho Univ, Sakura Med Ctr, Div Cardiovasc Surg, 7-3-1 564-1 Shimoshizu, Sakura, Chiba 2858741, Japan
[2] Univ Tokyo, Grad Sch Med, Dept Healthcare Qual Assessment, Tokyo, Japan
[3] Univ Tokyo, Dept Cardiothorac Surg, Tokyo, Japan
[4] Keio Univ, Dept Hlth Policy & Management, Tokyo, Japan
关键词
Anastomosis assist device; Off-pump coronary artery bypass grafting; Stroke; Side-biting clamp; OFF-PUMP; PROXIMAL ANASTOMOSIS; NO-TOUCH; STROKE; RISK; TRANSFUSION; EXPERIENCE; MORTALITY; SURGERY; SYSTEM;
D O I
10.1093/ejcts/ezy177
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: The use of an anastomosis assist device during coronary artery bypass grafting (CABG) is considered less invasive for the ascending aorta than the use of a side-biting clamp (Side-clamp) and to possibly be associated with a lower incidence of postoperative stroke. However, this benefit has not yet been clearly demonstrated. This study was to evaluate whether the use of an anastomosis assist device will minimize the postoperative stroke and other complications in patients undergoing off-pump CABG in comparison with the use of the Side-clamp. METHODS: Patients undergoing isolated off-pump CABG were retrospectively reviewed using the Japan Adult Cardiovascular Surgery Database (2013-2016). We performed a one-to-one matched analysis based on the estimated propensity scores of those who underwent off-pump CABG with an anastomosis assist device (Device group, n = 14 213) or a side-biting clamp (Side-clamp group, n = 7374) and obtained 2 cohorts (n = 7348 each). We compared the early outcomes and the details of postoperative complications using the Pearson's chi(2) test. P-values of <0.05 were considered to indicate statistical significance. RESULTS: No significant differences were observed in the rates of 30-day mortality (Side-clamp versus Device: 0.8% vs 0.8%, P = 0.93) or stroke (1.4% vs 1.4%, P = 0.46). Transient ischaemic attack/reversible ischaemic neurological deficit/delirium occurred more frequently in the Side-clamp group (1.3% vs 0.9%, P = 0.020), whereas new-onset atrial fibrillation (11.0% vs 12.8%, P < 0.001) and prolonged ventilation (2.0% vs 2.9%, P < 0.001) occurred more frequently in the Device group. There was no difference in the length of intensive care unit stay. CONCLUSIONS: The use of an anastomosis assist device partially provided better results with regard to the transient neurological complications; however, no overall benefit was observed in this study.
引用
收藏
页码:889 / 895
页数:7
相关论文
共 28 条
[1]   Clinical experience with the Novare Enclose II manual proximal anastomotic device during off-pump coronary artery surgery [J].
Akpinar, B ;
Gulden, M ;
Sagbas, E ;
Sanisoglu, H ;
Ergenoglu, MU ;
Turkoglu, C .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 27 (06) :1070-1073
[2]   Blood Transfusion and the Risk of Atrial Fibrillation after Cardiac Surgery [J].
Alameddine, Abdallah K. ;
Visintainer, Paul ;
Alimov, Victor K. ;
Rousou, John A. .
JOURNAL OF CARDIAC SURGERY, 2014, 29 (05) :593-599
[3]   Evaluation of the enclose proximal anastomosis device in coronary artery bypass grafting [J].
Aranki, SF ;
Shekar, PS ;
Ehsan, A ;
Byrne-Taft, M ;
Couper, GS .
ANNALS OF THORACIC SURGERY, 2005, 80 (03) :1091-1095
[4]   Off-pump no-touch technique: 3-year results compared with the SYNTAX trial [J].
Arrigoni, Sara C. ;
Mecozzi, Gianclaudio ;
Grandjean, Jan G. ;
Hillege, Jan L. ;
Kappetein, Arie P. ;
Mariani, Massimo A. .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 20 (05) :601-604
[5]  
Athanasiou T, 2006, J CARDIAC SURG, V21, P69, DOI 10.1111/j.1540-8191.2006.00172.x
[6]   Patency of Vein Graft Anastomoses Facilitated With the Hexalon Device [J].
Ayad, Ramy F. ;
Bhella, Paul S. ;
Dockery, William D. ;
Schussler, Jeffrey M. .
ANNALS OF THORACIC SURGERY, 2011, 91 (03) :894-898
[7]   Spyder aortic connector system in off-pump coronary artery bypass surgery [J].
Biancari, Fausto ;
Lahtinen, Jarmo ;
Ojala, Risto ;
Ahvenjarvi, Lauri ;
Jartti, Airi ;
Mosorin, Martti ;
Heikkinen, Jouni ;
Taskinen, Panu ;
Lepojarvi, Martti .
ANNALS OF THORACIC SURGERY, 2007, 84 (01) :254-258
[8]   Meta-analysis on the use of the Heartstring anastomotic device to prevent stroke in patients undergoing off-pump coronary artery bypass grafting [J].
Biancari, Fausto ;
Yli-Pyky, Sanna .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 40 (05) :1236-1240
[9]  
Coca-Perraillon M., 2007, 1852007 SAS GLOB FOR, P1
[10]   No-Touch Aorta Off-Pump Coronary Bypass Operation: Arteriovenous Composite Grafts May Be Used as a Last Resort [J].
Davierwala, Piroze M. ;
Leontyev, Sergey ;
Misfeld, Martin ;
Rastan, Ardawan ;
Holzhey, David ;
Lehmann, Sven ;
Borger, Michael A. ;
Mohr, Friedrich W. .
ANNALS OF THORACIC SURGERY, 2013, 95 (03) :846-853