Assessment of global cardiac I-123 MIBG uptake and washout using volumetric quantification of SPECT acquisitions

被引:17
|
作者
van der Veen, Berlinda J. [1 ]
Al Younis, Imad [1 ]
de Roos, Albert
Stokkel, Marcel P. M. [2 ]
机构
[1] Leiden Univ, Med Ctr, Dept Nucl Med, NL-2300 RC Leiden, Netherlands
[2] Antoni van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Nucl Med, Amsterdam, Netherlands
关键词
I-123; meta-iodobenzylguanidine; myocardial innervation; SPECT; quantitative analysis; SYMPATHETIC INNERVATION; VENTRICULAR-ARRHYTHMIAS; MYOCARDIAL-INFARCTION; VIABLE MYOCARDIUM; PROGNOSTIC VALUE; DISEASE; SCINTIGRAPHY; IODINE-123-MIBG; SYSTEM; RISK;
D O I
10.1007/s12350-012-9539-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Assessment of cardiac innervation using single-photon emission computer tomography (SPECT) is less established than planar imaging, but may be more suitable for quantification. Therefore, a volumetric quantification of I-123 MIBG SPECT acquisitions was performed. Reproducibility, the effects of extra cardiac I-123 MIBG uptake and the relation with conventional planar indices were evaluated. 54 patients referred for planar and SPECT I-123 MIBG acquisitions were included. Ellipsoidal or box-shaped volumes of interest were placed on the left ventricle, cardiac lumen, mediastinum, lung and liver. SPECT segmentation was performed twice in all patients. Indices were determined based on the heart-to-mediastinum (HM), myocardial wall-to-mediastinum and myocardial wall-to-lumen regions. HM ratios and washout rates were also determined based on anterior planar images. Cardiac count densities were highly reproducible (CV 1.5-5.4, ICC 0.96-0.99) and inter-rater variability was low (CV 1.8-6.8, ICC 0.94-0.99). Mediastinal uptake was an important explanatory variable of uptake in the entire heart (early R (2) = 0.36; delayed R (2) =0.43) and myocardial wall (early R (2) = 0.28; delayed R (2) = 0.37). Lung washout was an explanatory variable of organ washout of the heart (heart R (2) = 0.38; myocardial wall R (2) = 0.33). In general, SPECT indices showed moderate-to-good correlations with the planar uptake (PCC 0.497-0.851). By applying a volumetric segmentation method we were able to segment the heart in all patients. SPECT I-123 MIBG quantification was found to be highly reproducible and had a moderate to good correlation with the planar indices.
引用
收藏
页码:752 / 762
页数:11
相关论文
共 50 条
  • [21] The reversibility of cardiac neuronal function after removal of a pheochromocytoma - An I-123 MIBG scintigraphic study
    Agostini, D
    Darlas, Y
    Filmont, JE
    Dronne, F
    Babatasi, G
    Grollier, G
    Potier, JC
    Bouvard, G
    CLINICAL NUCLEAR MEDICINE, 1999, 24 (07) : 514 - 518
  • [22] Quantification and Determination of Normal 123I-Meta Iodobenzylguanidine Heart-to-Mediastinum Ratio (HMR) from Cardiac SPECT/CT and Correlation with Planar HMR
    Alvi, Raza
    Miller, Edward J.
    Zonouz, Taraneh Hashemi
    Sandoval, Veronica
    Tariq, Noor
    Lampert, Rachel
    Sinusas, Albert J.
    Liu, Yi-Hwa
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (04) : 652 - 658
  • [23] Compensatory uptake of I-123 MIBG in the contralateral adrenal gland after removal of a pheochromocytoma
    Boersma, HH
    Wensing, JW
    Kho, TL
    De Brauw, LM
    Liem, IH
    van Kroonenburgh, MJPG
    CLINICAL NUCLEAR MEDICINE, 2002, 27 (02) : 113 - 116
  • [24] Assessment of cardiac sympathetic innervation with 123I-mIBG SPECT comes to life: need for standardization!
    Verberne, Hein J.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (04) : 391 - 392
  • [25] I-123 MIBG cardiac scintigraphy and autonomic test evaluation in multiple sclerosis patients
    Lorberboym, Mordechai
    Lampl, Yair
    Nikolov, Galina
    Sadeh, Menachem
    Gilad, Ronit
    JOURNAL OF NEUROLOGY, 2008, 255 (02) : 211 - 216
  • [26] A Pictorial Review of I-123 MIBG Imaging of Neuroblastoma Utilizing a State-of-the-Art CZT SPECT/CT System
    Sweet, Cassidy
    Shmuel, Natalie
    Shoaf, Jennifer N.
    Stoecklein, Marcy
    Muthukrishnan, Ashok
    Stern, Eli
    Nguyen, Nghi C.
    NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 58 (01) : 1 - 8
  • [27] I-123 MIBG cardiac scintigraphy and autonomic test evaluation in multiple sclerosis patients
    M. Lorberboym
    Y. Lampl
    G. Nikolov
    M. Sadeh
    R. Gilad
    Journal of Neurology, 2008, 255 : 211 - 216
  • [28] Individuals with impaired glucose tolerance demonstrate normal cardiac sympathetic innervation using I-123 mIBG scintigraphy
    O. Asghar
    P. Arumugam
    I. S. Armstrong
    S. G. Ray
    M. Schmitt
    R. A. Malik
    Journal of Nuclear Cardiology, 2015, 22 : 1262 - 1268
  • [29] Scatter correction by two-window method standardizes cardiac I-123 MIBG uptake in various gamma camera systems
    Kobayashi, H
    Momose, M
    Kanaya, S
    Kondo, C
    Kusakabe, K
    Mitsuhashi, N
    ANNALS OF NUCLEAR MEDICINE, 2003, 17 (04) : 309 - 313
  • [30] Determination of the Heart-to-Mediastinum Ratio of 123I-MIBG Uptake Using Dual-Isotope (123I-MIBG/99mTc-Tetrofosmin) Multipinhole Cadmium-Zinc-Telluride SPECT in Patients with Heart Failure
    Blaire, Tanguy
    Bailliez, Alban
    Ben Bouallegue, Faycal
    Bellevre, Dimitri
    Agostini, Denis
    Manrique, Alain
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (02) : 251 - 258