Assessment of global cardiac I-123 MIBG uptake and washout using volumetric quantification of SPECT acquisitions

被引:17
|
作者
van der Veen, Berlinda J. [1 ]
Al Younis, Imad [1 ]
de Roos, Albert
Stokkel, Marcel P. M. [2 ]
机构
[1] Leiden Univ, Med Ctr, Dept Nucl Med, NL-2300 RC Leiden, Netherlands
[2] Antoni van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Nucl Med, Amsterdam, Netherlands
关键词
I-123; meta-iodobenzylguanidine; myocardial innervation; SPECT; quantitative analysis; SYMPATHETIC INNERVATION; VENTRICULAR-ARRHYTHMIAS; MYOCARDIAL-INFARCTION; VIABLE MYOCARDIUM; PROGNOSTIC VALUE; DISEASE; SCINTIGRAPHY; IODINE-123-MIBG; SYSTEM; RISK;
D O I
10.1007/s12350-012-9539-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Assessment of cardiac innervation using single-photon emission computer tomography (SPECT) is less established than planar imaging, but may be more suitable for quantification. Therefore, a volumetric quantification of I-123 MIBG SPECT acquisitions was performed. Reproducibility, the effects of extra cardiac I-123 MIBG uptake and the relation with conventional planar indices were evaluated. 54 patients referred for planar and SPECT I-123 MIBG acquisitions were included. Ellipsoidal or box-shaped volumes of interest were placed on the left ventricle, cardiac lumen, mediastinum, lung and liver. SPECT segmentation was performed twice in all patients. Indices were determined based on the heart-to-mediastinum (HM), myocardial wall-to-mediastinum and myocardial wall-to-lumen regions. HM ratios and washout rates were also determined based on anterior planar images. Cardiac count densities were highly reproducible (CV 1.5-5.4, ICC 0.96-0.99) and inter-rater variability was low (CV 1.8-6.8, ICC 0.94-0.99). Mediastinal uptake was an important explanatory variable of uptake in the entire heart (early R (2) = 0.36; delayed R (2) =0.43) and myocardial wall (early R (2) = 0.28; delayed R (2) = 0.37). Lung washout was an explanatory variable of organ washout of the heart (heart R (2) = 0.38; myocardial wall R (2) = 0.33). In general, SPECT indices showed moderate-to-good correlations with the planar uptake (PCC 0.497-0.851). By applying a volumetric segmentation method we were able to segment the heart in all patients. SPECT I-123 MIBG quantification was found to be highly reproducible and had a moderate to good correlation with the planar indices.
引用
收藏
页码:752 / 762
页数:11
相关论文
共 50 条
  • [1] Assessment of global cardiac I-123 MIBG uptake and washout using volumetric quantification of SPECT acquisitions
    Berlinda J. van der Veen
    Imad Al Younis
    Albert de Roos
    Marcel P. M. Stokkel
    Journal of Nuclear Cardiology, 2012, 19 : 752 - 762
  • [2] I-123 MIBG Cardiac Imaging
    Soman, Prem
    Travin, Mark I.
    Gerson, Myron
    Cullom, S. James
    Thompson, Randall
    JOURNAL OF NUCLEAR CARDIOLOGY, 2015, 22 (04) : 677 - 685
  • [3] A step forward in the use of SPECT imaging with I-123 MIBG
    Abdallah, Mouhamad
    Gerson, Myron C.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (01) : 16 - 18
  • [4] Quantitative I-123 mIBG SPECT in differentiating abnormal and normal mIBG myocardial uptake
    Ji Chen
    Russell D. Folks
    Liudmila Verdes
    Daya N. Manatunga
    Arnold F. Jacobson
    Ernest V. Garcia
    Journal of Nuclear Cardiology, 2012, 19 (1) : 92 - 99
  • [5] Additional value of I-123 MIBG SPECT in neuroblastoma
    Pirson, AS
    Krug, B
    Tuerlinckx, D
    Lacrosse, M
    Luyx, D
    Vander Borght, T
    CLINICAL NUCLEAR MEDICINE, 2005, 30 (02) : 100 - 101
  • [6] Uniformity of cardiac123I-MIBG uptake on SPECT images in older adults with normal cognition and patients with dementia
    Roberts, Gemma
    Lloyd, Jim J.
    Jefferson, Elizabeth
    Kane, Joseph P. M.
    Durcan, Rory
    Lawley, Sarah
    Petrides, George S.
    Howe, Kim
    Haq, Iftikhar
    O'Brien, John T.
    Thomas, Alan J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (05) : 2151 - 2163
  • [7] Comparison of I-123 MIBG planar imaging and SPECT for the detection of decreased heart uptake in Parkinson disease
    Oh, Jin-Kyoung
    Choi, Eun-Kyoung
    Song, In-Uk
    Kim, Joong-Seok
    Chung, Yong-An
    JOURNAL OF NEURAL TRANSMISSION, 2015, 122 (10) : 1421 - 1427
  • [8] Metastatic pulmonary pheochromocytomas: Positive I-123 MIBG SPECT with negative I-131 MIBG and equivocal I-123 MIBG planar imaging
    Tsuchimochi, S
    Nakajo, M
    Nakabeppu, Y
    Tani, A
    CLINICAL NUCLEAR MEDICINE, 1997, 22 (10) : 687 - 690
  • [9] The Utility of Segmental Analysis in Cardiac I-123 MIBG SPECT in Parkinson’s Disease
    Kwon S.H.
    Yoon J.-K.
    Yoon J.H.
    Lee S.J.
    Jo K.S.
    Lee D.H.
    An Y.-S.
    Nuclear Medicine and Molecular Imaging, 2015, 49 (4) : 298 - 302
  • [10] Radioactive defect on I-123 MIBG myocardial SPECT imaging in a patient with cardiac sarcoidosis
    Imai, E
    Kaminaga, T
    Takada, K
    Kutomi, K
    Furui, S
    CLINICAL NUCLEAR MEDICINE, 2002, 27 (10) : 729 - 730