Multisite EPR oximetry from multiple quadrature harmonics

被引:4
作者
Ahmad, R. [1 ]
Som, S. [2 ]
Johnson, D. H. [1 ]
Zweier, J. L. [1 ]
Kuppusamy, P. [1 ]
Potter, L. C. [3 ]
机构
[1] Ohio State Univ, Dept Internal Med, Davis Heart & Lung Res Inst, Columbus, OH 43210 USA
[2] Georgia Inst Technol, Sch Elect & Comp Engn, Atlanta, GA 30308 USA
[3] Ohio State Univ, Dept Elect & Comp Engn, Columbus, OH 43210 USA
关键词
EPR; Digital detection; Overmodulation; Quadrature harmonics; Multisite; Oximetry; IN-VIVO EPR; LINEWIDTH; SIGNAL; RECONSTRUCTION; SPECTROMETER; MODULATION; HYPEROXIA; SPECTRUM; HYPOXIA; TISSUES;
D O I
10.1016/j.jmr.2011.10.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Multisite continuous wave (CW) electron paramagnetic resonance (EPR) oximetry using multiple quadrature field modulation harmonics is presented. First, a recently developed digital receiver is used to extract multiple harmonics of field modulated projection data. Second, a forward model is presented that relates the projection data to unknown parameters, including linewidth at each site. Third, a maximum likelihood estimator of unknown parameters is reported using an iterative algorithm capable of jointly processing multiple quadrature harmonics. The data modeling and processing are applicable for parametric lineshapes under nonsaturating conditions. Joint processing of multiple harmonics leads to 2-3-fold acceleration of EPR data acquisition. For demonstration in two spatial dimensions, both simulations and phantom studies on an L-band system are reported. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:135 / 143
页数:9
相关论文
共 31 条
[21]   Novel particulate spin probe for targeted determination of oxygen in cells and tissues [J].
Pandian, RP ;
Parinandi, NL ;
Ilangovan, G ;
Zweier, JL ;
Kuppusamy, P .
FREE RADICAL BIOLOGY AND MEDICINE, 2003, 35 (09) :1138-1148
[22]   Linewidth analysis of spin labels in liquids - I. Theory and data analysis [J].
Robinson, BH ;
Mailer, C ;
Reese, AW .
JOURNAL OF MAGNETIC RESONANCE, 1999, 138 (02) :199-209
[23]   Half-Life Mapping of Nitroxyl Radicals with Three-Dimensional Electron Paramagnetic Resonance Imaging at an Interval of 3.6 Seconds [J].
Sato-Akaba, Hideo ;
Kuwahara, Yoko ;
Fujii, Hirotada ;
Hirata, Hiroshi .
ANALYTICAL CHEMISTRY, 2009, 81 (17) :7501-7506
[24]   Hypoxia induces chemoresistance in ovarian cancer cells by activation of signal transducer and activator of transcription 3 [J].
Selvendiran, Karuppaiyah ;
Bratasz, Anna ;
Kuppusamy, M. Lakshmi ;
Tazi, Mia F. ;
Rivera, Brian K. ;
Kuppusamy, Periannan .
INTERNATIONAL JOURNAL OF CANCER, 2009, 125 (09) :2198-2204
[25]  
Smirnov A., 1993, MAGN RESON MED, P213
[26]  
Smirnov A., 2004, CONVOLUTION BASED AL, P277
[27]   EPR oximetry in three spatial dimensions using sparse spin distribution [J].
Som, Subhojit ;
Potter, Lee C. ;
Ahmad, Rizwan ;
Vikram, Deepti S. ;
Kuppusamy, Periannan .
JOURNAL OF MAGNETIC RESONANCE, 2008, 193 (02) :210-217
[28]   A parametric approach to spectral-spatial EPR imaging [J].
Som, Subhojit ;
Potter, Lee C. ;
Ahmad, Rizwan ;
Kuppusamy, Periannan .
JOURNAL OF MAGNETIC RESONANCE, 2007, 186 (01) :1-10
[29]  
Tseitlin MP, 2009, APPL MAGN RESON, V35, P569, DOI [10.1007/s00723-009-0186-0, 10.1007/S00723-009-0186-0]
[30]   Reconstruction of the first-derivative EPR spectrum from multiple harmonics of the field-modulated continuous wave signal [J].
Tseitlin, Mark ;
Eaton, Sandra S. ;
Eaton, Gareth R. .
JOURNAL OF MAGNETIC RESONANCE, 2011, 209 (02) :277-281