Effects of EDTA on chemiluminescent immunoassay measurement of ACTH, cortisol, and thyroid hormones in dogs

被引:2
作者
Hirsch, A. L. [1 ]
Fletcher, J. M. [1 ,2 ]
Mitchell, M. A. [1 ]
机构
[1] Louisiana State Univ, Sch Vet Med, Dept Vet Clin Sci, Baton Rouge, LA 70803 USA
[2] Louisiana State Univ, Louisiana Anim Dis Diagnost Lab, Baton Rouge, LA 70803 USA
关键词
Cortisol; EDTA; Assay interference; Alkaline phosphatase; Chemiluminescent immunoassay; ADRENOCORTICOTROPIC HORMONE; BASAL SERUM; PLASMA; DIAGNOSIS; HYPOADRENOCORTICISM; VALIDATION; THYROXINE; STORAGE; RADIOIMMUNOASSAY; ASSAY;
D O I
10.1016/j.domaniend.2021.106707
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
A B S T R A C T When measuring blood hormones, pre-analytical sample handling can impact the quality of the results. Previous studies have shown improved stability of canine cortisol in ethylenediaminetetraacetic acid (EDTA) plasma compared to serum and interchangeability of serum and plasma when cortisol is measured by radioimmunoassay. Additionally, cortisol samples were also interchangeable when measured by chemiluminescent immunoassay if the EDTA concentration was consistent with that of optimally filled tubes, whereas excess EDTA interfered with the measurement of cortisol and serum and EDTA plasma were not interchangeable when measuring total thyroxine (TT4). The main limitation of these studies was that they were performed by spiking pooled serum samples with EDTA or in previously collected blood samples submitted to a clinical pathology laboratory. The purpose of the present study was to evaluate the effect of EDTA on the measurement of adrenocorticotropic hormone (ACTH), cortisol, TT4, free thyroxine (FT4), and thyroid stimulating hormone (TSH) in healthy dogs using the Siemens IMMULITE 10 0 0. Whole blood from forty dogs was aliquoted into three Monoject sample tubes: no additive, completely filled EDTA tube, and 50% filled EDTA tube. Handling and storage conditions were identical, and all samples were analyzed on the same day. Bland-Altman plots and Passing-Bablok regression were used to assess agreement and risks for error, respectively. Proportional errors were found between serum and plasma samples for ACTH, cortisol, TT4, FT4, and TSH; systematic errors were also found for FT4. There was poor agreement and clinically significant differences between the measured concentrations of all hormones in serum and plasma, proving that these sample types are not interchangeable. Incompletely filled EDTA tubes were associated with significantly lower ACTH concentrations compared to completely filled EDTA tubes. When measured by chemiluminescent immunoassays that utilize alkaline phosphatase at the reporter enzyme, serum should be used for cortisol, TT4, FT4, and TSH, while plasma from completely filled EDTA tubes should be used for ACTH.(c) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页数:7
相关论文
共 24 条
[1]   Issue Information [J].
Arnold, Jill E. ;
Camus, Melinda S. ;
Freeman, Kathy P. ;
Giori, Luca ;
Hooijberg, Emma H. ;
Jeffery, Unity ;
Korchia, Jeremie ;
Meindel, Mandy J. ;
Moore, A. Russell ;
Sisson, Sandra C. ;
Vap, Linda M. ;
Cook, Jennifer R. .
VETERINARY CLINICAL PATHOLOGY, 2019, 48 (04) :542-618
[2]  
Behrend EN, 1998, J AM VET MED ASSOC, V212, P1564
[3]  
Bonini P, 2002, CLIN CHEM, V48, P691
[4]   Interferences from blood collection tube components on clinical chemistry assays [J].
Bowen, Raffick A. R. ;
Remaley, Alan T. .
BIOCHEMIA MEDICA, 2014, 24 (01) :31-44
[5]   Current laboratory requirements for adrenocorticotropic hormone and renin/aldosterone sample handling are unnecessarily restrictive [J].
Chakera, Ali J. ;
McDonald, Timothy J. ;
Knight, Bridget A. ;
Vaidya, Bijay ;
Jones, Angus G. .
CLINICAL MEDICINE, 2017, 17 (01) :18-21
[6]  
Glendenning P, 2002, CLIN CHEM, V48, P566
[7]   Evaluation of Basal Serum or Plasma Cortisol Concentrations for the Diagnosis of Hypoadrenocorticism in Dogs [J].
Gold, A. J. ;
Langlois, D. K. ;
Refsal, K. R. .
JOURNAL OF VETERINARY INTERNAL MEDICINE, 2016, 30 (06) :1798-1805
[8]  
HEGSTAD RL, 1990, AM J VET RES, V51, P1941
[9]   Excess EDTA interferes with cortisol measurement using a solid-phase, chemiluminescent enzyme immunoassay [J].
Kemppainen, Robert J. ;
Behrend, Ellen N. ;
Carter, Stephanie F. ;
Cole, Janeva E. .
JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2018, 30 (03) :438-441
[10]   Use of the Cortisol-to-ACTH Ratio for Diagnosis of Primary Hypoadrenocorticism in Dogs [J].
Lathan, P. ;
Scott-Moncrieff, J. C. ;
Wills, R. W. .
JOURNAL OF VETERINARY INTERNAL MEDICINE, 2014, 28 (05) :1546-1550