Imaging Retinal Capillaries Using Ultrahigh-Resolution Optical Coherence Tomography and Adaptive Optics

被引:60
|
作者
Wang, Qiang [1 ]
Kocaoglu, Omer P. [1 ]
Cense, Barry [1 ]
Bruestle, Jeremy [1 ]
Jonnal, Ravi S. [1 ]
Gao, Weihua [1 ]
Miller, Donald T. [1 ]
机构
[1] Indiana Univ, Sch Optometry, Bloomington, IN 47405 USA
关键词
FOVEAL AVASCULAR ZONE; PSYCHOPHYSICAL MEASUREMENT; PRIMATE AREA; HIGH ACUITY; MICROCIRCULATION; VISUALIZATION; FIXATION; OCT;
D O I
10.1167/iovs.10-6424
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Ultrahigh-resolution optical coherence tomography (UHR-OCT) with adaptive optics (AO) provides micrometer-scale 3D resolution that is attractive for imaging the retinal microvasculature. Such imaging may be useful for early detection of pathologic changes as in diabetic retinopathy. Here the authors investigate this potential for detecting individual capillaries in healthy subjects. METHODS. UHR-AO-OCT volumes centered on the fovea were acquired from seven subjects (age range, 25-61 years) with three preselected with no foveal avascular zone (FAZ). Images were compared with entoptic diagrams using the capillaries at the rim of the FAZ. Methods of comparison were testing for the presence of a FAZ, noting distinct features in the capillary pattern, and measuring the size of the FAZ. Additional analysis included measurements of capillary diameter and depth range with retinal eccentricity. RESULTS. UHR-AO-OCT results are consistent with entoptic observations for all three methods of comparison. FAZ diameters measured by UHR-AO-OCT and entoptic imaging are strongly correlated (R-2 = 0.86). Average capillary diameter near the FAZ rim is 5.1 (4.6) +/- 1.4 mu m, with the value in parentheses accounting for axial image blur. This is consistent with histology (average, similar to 4.7 mu m). Depth range of the capillaries increases monotonically with eccentricity (0 degrees-1.25 degrees) and is larger and more variable for subjects without FAZ. CONCLUSIONS. UHR-AO-OCT permits observation of many of the capillaries proximal to the FAZ, including those of average size based on published histology. This supports the view that the vast majority of capillaries in the retina are likely detectable with UHR-AO-OCT. (Invest Ophthalmol Vis Sci. 2011;52:6292-6299) DOI:10.1167/iovs.10-6424
引用
收藏
页码:6292 / 6299
页数:8
相关论文
共 50 条
  • [1] Adaptive-optics ultrahigh-resolution optical coherence tomography
    Hermann, B
    Fernández, EJ
    Unterhuber, A
    Sattmann, H
    Fercher, AF
    Drexler, W
    Prieto, PM
    Artal, P
    OPTICS LETTERS, 2004, 29 (18) : 2142 - 2144
  • [2] Ultrahigh-Resolution Adaptive Optics -: Optical Coherence Tomography:: Towards isotropic 3 μm resolution for in vivo retinal imaging
    Zawadzki, Robert J.
    Zhang, Yan
    Jones, Steven M.
    Ferguson, R. Daniel
    Choi, Stacey S.
    Cense, Barry
    Evans, Julia W.
    Chen, Diana
    Miller, Donald T.
    Olivier, Scot S.
    Werner, John S.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XI, 2007, 6429
  • [3] Retinal oximetry using ultrahigh-resolution optical coherence tomography
    Ye, Yufeng
    Jiang, Hong
    Shen, Meixiao
    Lam, Byron L.
    DeBuc, Delia Cabrera
    Ge, Lili
    Sehi, Mitra
    Wang, Jianhua
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 2085 - 2092
  • [4] Ultrahigh-Speed Ultrahigh-Resolution Adaptive Optics - Optical Coherence Tomography System for In-vivo Small Animal Retinal Imaging
    Jian, Yifan
    Xu, Jing
    Zawadzki, Robert J.
    Sarunic, Marinko V.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XVII, 2013, 8571
  • [5] Volumetric retinal imaging with ultrahigh-resolution spectral-domain optical coherence tomography and adaptive optics using two broadband light sources
    Cense, Barry
    Koperda, Eric
    Brown, Jeffrey M.
    Kocaoglu, Omer P.
    Gao, Weihua
    Jonnal, Ravi S.
    Miller, Donald T.
    OPTICS EXPRESS, 2009, 17 (05): : 4095 - 4111
  • [6] Adaptive optics using a liquid crystal spatial light modulator for ultrahigh-resolution optical coherence tomography
    Fernandez, Enrique J.
    Povazay, Boris
    Hermann, Boris
    Unterhuber, Angelika
    Sattmann, Harald
    Prieto, Pedro M.
    Leitgeb, Rainer
    Ahnelt, Peter
    Artal, Pablo
    Drexler, Wolfgang
    OPHTHALMIC TECHNOLOGIES XVI, 2006, 6138
  • [7] Ultrahigh-resolution optical coherence tomography of canthaxanthine retinal crystals
    Chan, A
    Ko, TH
    Duker, JS
    OPHTHALMIC SURGERY LASERS & IMAGING, 2006, 37 (02) : 138 - 139
  • [8] Ultrahigh-resolution optical coherence tomography
    Drexler, W
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) : 47 - 74
  • [9] Adaptive optics ultrahigh resolution optical coherence tomography
    Drexler, W
    Fernandez, EJ
    Hermann, B
    Unterhuber, B
    Sattmann, H
    Prieto, PM
    Fercher, AF
    Artal, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U929 - U929
  • [10] Myocardial imaging using ultrahigh-resolution spectral domain optical coherence tomography
    Yao, Xinwen
    Gan, Yu
    Marboe, Charles C.
    Hendon, Christine P.
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (06)