Locked plating as an external fixator in treating tibial fractures A PRISMA-compliant systematic review

被引:13
|
作者
Luo, Peng [1 ,2 ,3 ]
Xu, Ding [4 ]
Wu, Jia [5 ]
Chen, Yi-Heng [1 ,2 ,3 ]
机构
[1] Wenzhou Med Univ, Affiliated Hosp 2, Dept Trauma Orthoped, Wenzhou, Peoples R China
[2] Wenzhou Med Univ, Yuying Childrens Hosp, Wenzhou, Peoples R China
[3] Zhejiang Prov Key Lab Orthopaed, Wenzhou, Peoples R China
[4] Shangyu Peoples Hosp Shaoxing City, Dept Trauma Orthoped, Shaoxing, Peoples R China
[5] Wenzhou Med Univ, Key Lab Lab Med, Zhejiang Prov Key Lab Med Genet, Minist Educ,Sch Lab Med & Life Sci, Wenzhou, Zhejiang, Peoples R China
关键词
external fixator; fracture fixation; locked plating; tibia; LOCKING COMPRESSION PLATE; OSTEOSYNTHESIS; BONE;
D O I
10.1097/MD.0000000000009083
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: This article is a systematic review of the published literature about the biomechanics, functional outcomes, and complications of a locked plate as an external fixator in treating tibial fractures. Methods: We searched the PubMed, Ovid Medline, Embase, ScienceDirect, and Cochrane Library databases to retrieve the relevant studies. Studies published in English and Chinese which assessed adult patients and more than 4 cases who had sustained any type of fresh tibial fracture treated with the external locking plate, provided that they reported functional outcomes, range of motion (ROM), union or complication rates, and the biomechanical studies of external locked plating are also included. Results: The electronic search strategy revealed 248 studies, and 2 studies were identified as relevant through manual search of references. Finally, 12 studies were included in this systematic review. These consist of 3 pure biomechanical studies, 8 case series, and 1 study including both of biomechanics and case series. Due to the heterogeneity of biomechanical studies, we can only conclude that external locked plate shows inferior structural stiffness than internal locked plate. The clinical studies reported that external locked plating gave a satisfactory ROM of the knee and ankle, functional outcomes, union rate, and low complication rate. Conclusions: We can only conclude that external locked plate shows inferior structural stiffness than internal locked plate because of the heterogeneity of biomechanical studies. The clinical studies showed locked plating as an external fixator in treating tibial fractures can be considered as a safe and successful procedure. However, as yet, there is unconvincing evidence that it is superior to standard techniques with regards to clinical and functional outcomes. More and well-designed studies about this technique should be carried out.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] External fixator versus Ilizarov external fixator for pediatric tibial shaft fractures: A retrospective comparative study
    Hui, Taotao
    Wang, Jun
    Yu, Yinghao
    Dong, Haojuan
    Lin, Weifeng
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (04):
  • [12] Tibial pilon fractures treated with hybrid external fixator: analysis of 75 cases
    Scaglione M.
    Celli F.
    Casella F.
    Fabbri L.
    MUSCULOSKELETAL SURGERY, 2019, 103 (1) : 83 - 89
  • [13] Locking compression plate as an external fixator in the treatment of closed distal tibial fractures
    Yu Zhou
    Yanbiao Wang
    Lifeng Liu
    Zhenyu Zhou
    Xuecheng Cao
    International Orthopaedics, 2015, 39 : 2227 - 2237
  • [14] Locking compression plate as an external fixator in the treatment of closed distal tibial fractures
    Zhou, Yu
    Wang, Yanbiao
    Liu, Lifeng
    Zhou, Zhenyu
    Cao, Xuecheng
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (11) : 2227 - 2237
  • [15] Dual locked plating of unstable bicondylar tibial plateau fractures
    Ozkaya, Ufuk
    Parmaksizoglu, Atilla Sancar
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 : S9 - S13
  • [16] Staged external and internal locked plating for open distal tibial fractures A retrospective study of 16 patients
    Ma, Ching-Hou
    Yu, Shang-Won
    Tu, Yuan-Kun
    Yen, Cheng-Yo
    Yeh, James Jih-Hsi
    Wu, Chin-Hsien
    ACTA ORTHOPAEDICA, 2010, 81 (03) : 382 - 386
  • [17] Plating after tibial lengthening: unilateral monoaxial external fixator and locking plate
    Cha, Soo-Min
    Shin, Hyun-Dae
    Kim, Kyung-Cheon
    Song, Jae-Hwang
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2013, 22 (06): : 571 - 576
  • [18] Single-Stage Externalized Locked Plating for Treatment of Unstable Meta-Diaphyseal Tibial Fractures
    Makelov, Biser
    Mischler, Dominic
    Varga, Peter
    Apivatthakakul, Theerachai
    Fletcher, James W. A.
    Veselinov, Deyan
    Berk, Till
    Raykov, Dimitur
    Gueorguiev, Boyko
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (04)
  • [19] Is the external fixator yet useful for treating fractures of the distal radius?
    Rongières M.
    European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (8) : 1495 - 1497
  • [20] The role of plating in the operative treatment of severe open tibial fractures: a systematic review
    Giannoudis, Peter V.
    Papakostidis, Costas
    Kouvidis, George
    Kanakaris, Nikolaos K.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (01) : 19 - 26