Method for mounting radulae for SEM using an adhesive tape desiccation chamber

被引:0
作者
Moretzsohn, F [1 ]
机构
[1] Univ Hawaii, Dept Zool, Honolulu, HI 96822 USA
关键词
radula; SEM; mounting; method; desiccation;
D O I
暂无
中图分类号
Q17 [水生生物学];
学科分类号
071004 ;
摘要
A method to mount radulae for low-magnification SEM study is described. The wet radula was arranged over the adhesive side of a piece of adhesive tape. The addition of a few drops of liquid delayed desiccation, permitting the radula to be positioned. A piece of clear plastic film was added to form a desiccation chamber. Pinpricks around the radula allowed it to desiccate slowly. The desiccation chamber was then cut near the radula, and the radula and its adhesive base were mounted on an SEM stub. The method is simple and prepares radulae with little deformation.
引用
收藏
页码:145 / 146
页数:2
相关论文
共 26 条
[1]   A method for yield prediction using a SEM-ADC [J].
Mizuno, F ;
Isogai, S .
IN-LINE CHARACTERIZATION, YIELD RELIABILITY, AND FAILURE ANALYSES IN MICROELECTRONIC MANUFACTURING, 1999, 3743 :332-342
[2]   An improved quantification method for characterisation of clay microstructure using SEM [J].
Xu, Liyang ;
Xu, Riqing ;
Shashank, Bettadapura Subramanyam ;
Chen, Xiaohui ;
Yu, Jianlin ;
Wu, Chuangzhou .
ENVIRONMENTAL GEOTECHNICS, 2022, 11 (04) :319-338
[3]   Strain analysis on porous TiNiSMA using SEM Moire method [J].
Du, Hua ;
Xie, Huimin ;
Jiang, Haichang ;
Rong, Lijian ;
Luo, Qiang ;
Gu, Changzhi ;
Zhao, Yapu .
Experimental Mechanics in Nano and Biotechnology, Pts 1 and 2, 2006, 326-328 :79-82
[4]   Sticker method for preparation of frozen section using adhesive film [J].
Ryu, Bikei ;
Sekine, Hidekazu ;
Kawamata, Takakazu ;
Shimizu, Tatsuya .
JOURNAL OF NEUROSCIENCE METHODS, 2019, 328
[5]   3-D measurement method based on Wavelet transform by using SEM [J].
Arai, Y. ;
Ando, M. ;
Yokozeki, S. .
OPTICAL INSPECTION AND METROLOGY FOR NON-OPTICS INDUSTRIES, 2009, 7432
[6]   In situ cryo-FIB/SEM Specimen Preparation Using the Waffle Method [J].
Klykov, Oleg ;
Bobe, Daija ;
Paraan, Mohammadreza ;
Johnston, Jake D. ;
Potter, Clinton S. ;
Carragher, Bridget ;
Kopylov, Mykhailo ;
Noble, Alex J. .
BIO-PROTOCOL, 2022, 12 (21)
[7]   Improved monitoring of cryptogam gas-exchange and volatile emissions during desiccation-rehydration cycles with a within-chamber hydration method [J].
Morales-Sanchez, Jose Angel ;
Mark, Kristiina ;
Talts, Eero ;
Rasulov, Bakhtier ;
Niinemets, Ulo .
PLANT SCIENCE, 2023, 333
[8]   Analyses of the spreading kinetics of AgCuTi melts on silicon carbide below 900 °C, using a large-chamber SEM [J].
Tillmann, Wolfgang ;
Pfeiffer, Jan ;
Sievers, Norman ;
Boettcher, Konrad .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2015, 468 :167-173
[9]   New Method in SEM Analysis Using the Apriori Algorithm to Accelerate the Goodness of Fit Model [J].
Novita, Dien ;
Ermatita ;
Samsuryadi ;
Rini, Dian Palupi .
INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2024, 15 (11) :628-636
[10]   A study on customer satisfaction in mobile telecommunication market by using SEM and system dynamic method [J].
Li, Yuanquan ;
Qi, Jiayin ;
Shu, Huaying .
RESEARCH AND PRACTICAL ISSUES OF ENTERPRISE INFORMATION SYSTEMS II, VOL 2, 2008, 255 :1221-+