Design of passive mixers utilizing microfluidic self-circulation in the mixing chamber

被引:66
作者
Chung, YC [1 ]
Hsu, YL
Jen, CP
Lu, MC
Lin, YC
机构
[1] Elect Res & Serv Org, Ind Technol Res Inst, Hsinchu, Taiwan
[2] Natl Tsing Hua Univ, Dept Life Sci, Hsinchu, Taiwan
[3] Natl Cheng Kung Univ, Dept Engn Sci, Tainan 70101, Taiwan
[4] Ind Technol Res Inst, Energy & Resources Labs, Hsinchu, Taiwan
关键词
D O I
10.1039/b310848c
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper proposes the design of a passive micromixer that utilizes the self-circulation of the fluid in the mixing chamber for applications in the Micro Total Analysis Systems (muTAS). The micromixer with a total volume of about 20 muL and consisting of an inlet port, a circular mixing chamber and an outlet port was designed. The device was actuated by a pneumatic pump to induce self-circulation of the fluid. The self-circulation phenomenon in the micromixer was predicted by the computational simulation of the microfluidic dynamics. Flow visualization with fluorescence tracer was used to verify the numerical simulations and indicated that the simulated and the experimental results were in good agreement. Besides, an index for quantifying the mixing performance was employed to compare different situations and to demonstrate the advantages of the self-circulation mixer. The mixing efficiencies in the mixer under different Reynolds numbers ( Re) were evaluated numerically. The numerical results revealed that the mixing efficiency of the mixer with self-circulation was 1.7 to 2 times higher than that of the straight channel without a mixing chamber at Re = 150. When Re was as low as 50, the mixing efficiency of the mixer with self-circulation in the mixing chamber was improved approximately 30% higher than that in the straight channel. The results indicated that the self-circulation in the mixer could enhance the mixing even at low Re. The features of simple mixing method and fabrication process make this micromixer ideally suitable for mTAS applications.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 23 条
  • [1] BABA Y, 2002, MICRO TOTAL ANAL SYS
  • [2] Bird R.B., 2006, TRANSPORT PHENOMENA, Vsecond, DOI 10.1002/aic.690070245
  • [3] Bohm S, 2001, P MU TAS 2001 S CAL, P25
  • [4] Fast mixing by lamination.
    Branebjerg, J
    Gravesen, P
    Krog, JP
    Nielsen, CR
    [J]. NINTH ANNUAL INTERNATIONAL WORKSHOP ON MICRO ELECTRO MECHANICAL SYSTEMS, IEEE PROCEEDINGS: AN INVESTIGATION OF MICRO STRUCTURES, SENSORS, ACTUATORS, MACHINES AND SYSTEMS, 1996, : 441 - 446
  • [5] BRANEBJERG J, 1994, P MICR TOT AN SYST W, P141
  • [6] An integrated nanoliter DNA analysis device
    Burns, MA
    Johnson, BN
    Brahmasandra, SN
    Handique, K
    Webster, JR
    Krishnan, M
    Sammarco, TS
    Man, PM
    Jones, D
    Heldsinger, D
    Mastrangelo, CH
    Burke, DT
    [J]. SCIENCE, 1998, 282 (5388) : 484 - 487
  • [7] Evans J, 1997, PROC IEEE MICR ELECT, P96
  • [8] Mixing characteristics of T-type microfluidic mixers
    Gobby, D
    Angeli, P
    Gavriilidis, A
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2001, 11 (02) : 126 - 132
  • [9] HONG CC, 2001, P MU TAS 2001 S CAL, P3133
  • [10] Jen CP, 2003, SENSOR ACTUAT B-CHEM, V96, P701, DOI [10.1016/S0925-4005(03)00553-7, 10.1016/S0925-4005(03)0553-7]