Synchrotron X-ray computed microtomography: studies on vesiculated basaltic rocks

被引:60
|
作者
Song, SR
Jones, KW
Lindquist, WB
Dowd, BA
Sahagian, DL
机构
[1] Natl Taiwan Univ, Dept Geosci, Taipei 10764, Taiwan
[2] Brookhaven Natl Lab, Dept Appl Sci, Upton, NY 11973 USA
[3] Univ New Hampshire, Dept Earth Sci, Inst Earth Oceans & Space, Durham, NH 03824 USA
基金
美国国家科学基金会;
关键词
volcanology; image analysis; tomography; vesicularity;
D O I
10.1007/s004450100141
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Synchrotron X-ray computed microtomography (CMT) was applied to five basalt samples from different locations in order to determine the microgeometrical structures and physical properties of vesicles. Two vesiculated basaltic lavas and one calcite-filled vesiculated basaltic lava were collected from the Lesotho Highland, South Africa, and two basaltic scoria tephra were taken from the Lungkuan Volcano Group in northeast China. They were examined with CMT on the X27C beam line of the Brookhaven National Synchrotron Light Source. The voxel size varied from 10 to 20 mum depending on the chosen field of view of the tomographic instrument. A fast-filtered back-transform (FFBT) algorithm was employed in the tomographic reconstruction. A 3D image geometry analysis package was used to measure the vesicularity, specific surface area and interconnectivity of the vesicles. The results of the analyses showed that the bubbles have roughly spheroidal forms of different sizes. Vesicularity ranged from 45% for lavas to 80% for scoria. At least 90% of the vesicles are interconnected. Specific surface area was determined both by counting voxel faces and by use of two-point correlation functions.
引用
收藏
页码:252 / 263
页数:12
相关论文
共 50 条
  • [21] USE OF X-RAY COMPUTED MICROTOMOGRAPHY IN THE HETEROGENEITY ANALYSIS OF POLISH ZECHSTEIN CARBONATE ROCKS
    Kaczmarek, Lukasz
    Maksimczuk, Michal
    Wejrzanowski, Tomasz
    Krzyzak, Artur
    16TH INTERNATIONAL MULTIDISCIPLINARY SCIENTIFIC GEOCONFERENCE, SGEM 2016: SCIENCE AND TECHNOLOGIES IN GEOLOGY, EXPLORATION AND MINING, VOL III, 2016, : 1027 - +
  • [22] BEATS: BEAmline for synchrotron X-ray microTomography at SESAME
    Iori, Gianluca
    Alzu'bi, Mustafa
    Abbadi, Anas
    Al Momani, Yazeed
    Hasoneh, Abdel Rahman
    Van Vaerenbergh, Pierre
    Cudin, Ivan
    Marcos, Jordi
    Ahmad, Abdalla
    Mohammad, Anas
    Matalgah, Salman
    Foudeh, Ibrahim
    Al Najdawi, Mohammad
    Amro, Adel
    Rehman, Abid Ur
    Abugharbiyeh, Mohammad
    Khrais, Rami
    Aljadaa, Amro
    Nour, Mohammad
    Al Mohammad, Hussam
    Al Omari, Farouq
    Salama, Majeda
    Fuste, Maria Jose Garcia
    Reyes-Herrera, Juan
    Morawe, Christian
    Attal, Maher
    Kasaei, Samira
    Chrysostomou, Charalambos
    Kolodziej, Tomasz
    Boruchowski, Mateusz
    Nowak, Pawel
    Wiechecki, Jaroslaw
    Fatima, Anis
    Ghigo, Andrea
    Wawrzyniak, Adriana, I
    Lorentz, Kirsi
    Paolucci, Giorgio
    Lehner, Frank
    Krisch, Michael
    Stampanoni, Marco
    Rack, Alexander
    Kaprolat, Axel
    Lausi, Andrea
    JOURNAL OF SYNCHROTRON RADIATION, 2024, 31 : 1358 - 1372
  • [23] Synchrotron X-Ray microtomography of the interior microstructure of chocolate
    Luegger, Svenja K.
    Wilde, Fabian
    Duelger, Nihan
    Reinke, Lennart M.
    Kozhar, Sergii
    Beckmann, Felix
    Greving, Imke
    Vieira, Joselio
    Heinrich, Stefan
    Palzer, Stefan
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [24] X-ray diffraction microtomography using synchrotron radiation
    Barroso, RC
    Lopes, RT
    de Jesus, EFO
    Oliveira, LF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2): : 75 - 79
  • [25] USING SYNCHROTRON X-RAY MICROTOMOGRAPHY TO DETECT DEFECTS
    MILEWSKI, JO
    HMELO, AB
    DAMICO, KL
    DUNSMUIR, JH
    FERGUSON, SR
    WELDING JOURNAL, 1994, 73 (02) : 45 - 49
  • [26] Contrasting of Biological Samples for X-Ray Synchrotron Microtomography
    Efimova, O. I.
    Khlebnikov, A. S.
    Senin, R. A.
    Voronin, P. A.
    Anokhin, K. V.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2013, 155 (04) : 413 - 416
  • [27] X-ray transmission microtomography using synchrotron radiation
    Lopes, RT
    Rocha, HS
    de Jesus, EFO
    Barroso, RC
    de Oliveira, LF
    Anjos, MJ
    Braz, D
    Moreira, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 604 - 607
  • [28] Contrasting of Biological Samples for X-Ray Synchrotron Microtomography
    O. I. Efimova
    A. S. Khlebnikov
    R. A. Senin
    P. A. Voronin
    K. V. Anokhin
    Bulletin of Experimental Biology and Medicine, 2013, 155 : 413 - 416
  • [29] X-ray Microtomography at Shanghai Synchrotron Radiation Facility
    Chen, Rongchang
    Xie, Honglan
    Deng, Biao
    Du, Guohao
    Ren, Yuqi
    Wang, Yudan
    Zhou, Guangzhao
    Tan, Hai
    Yang, Yiming
    Xu, Liang
    Hu, Tao
    Li, Qiao
    Feng, Binggang
    Wang, Feixiang
    Xiao, Tiqiao
    DEVELOPMENTS IN X-RAY TOMOGRAPHY X, 2016, 9967
  • [30] Mapping metal catalysts using synchrotron computed microtomography and micro X-ray fluorescence.
    Jones, KW
    Feng, H
    Mahajan, D
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 226 : U569 - U569