3D medical thermography device

被引:5
作者
Moghadam, Peyman [1 ]
机构
[1] CSIRO, Autonomous Syst, Pullenvale, Qld 4069, Australia
来源
THERMOSENSE: THERMAL INFRARED APPLICATIONS XXXVII | 2015年 / 9485卷
关键词
3D medical thermography; handheld; thermal-infrared; medical thermal imaging; thermogram;
D O I
10.1117/12.2177880
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a novel handheld 3D medical thermography system is introduced. The proposed system consists of a thermal-infrared camera, a color camera and a depth camera rigidly attached in close proximity and mounted on an ergonomic handle. As a practitioner holding the device smoothly moves it around the human body parts, the proposed system generates and builds up a precise 3D thermogram model by incorporating information from each new measurement in real-time. The data is acquired in motion, thus it provides multiple points of view. When processed, these multiple points of view are adaptively combined by taking into account the reliability of each individual measurement which can vary due to a variety of factors such as angle of incidence, distance between the device and the subject and environmental sensor data or other factors influencing a confidence of the thermal-infrared data when captured. Finally, several case studies are presented to support the usability and performance of the proposed system.
引用
收藏
页数:8
相关论文
共 38 条
  • [31] First demonstration of 3-D lymphatic mapping in breast cancer using freehand SPECT
    Wendler, Thomas
    Herrmann, Ken
    Schnelzer, Andreas
    Lasser, Tobias
    Traub, Joerg
    Kutter, Olivier
    Ehlerding, Alexandra
    Scheidhauer, Klemens
    Schuster, Tibor
    Kiechle, Marion
    Schwaiger, Markus
    Navab, Nassir
    Ziegler, Sibylle I.
    Buck, Andreas K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (08) : 1452 - 1461
  • [32] Effects of integrated takeover request warning with personal portable device on takeover time and post-takeover performance in level 3 driving automation
    Talukder, Niloy
    Lee, Chris
    Kim, Yong Hoon
    Balasingam, Balakumar
    Biondi, Francesco
    Murugan, Aditya Subramani
    Kim, Eunsik
    JOURNAL OF SAFETY RESEARCH, 2024, 91 : 314 - 325
  • [33] Dual modality handheld adaptive optics optical coherence tomography probe for in vivo 3-D photoreceptor imaging
    Hagan, Kristen
    Park, Jongwan
    DuBose, Theodore B.
    Soltanian-Zadeh, Somayyeh
    Dhalla, Al-Hafeez
    Kuo, Anthony N.
    McNabb, Ryan P.
    Izatt, Joseph A.
    Farsiu, Sina
    OPHTHALMIC TECHNOLOGIES XXXIII, 2023, 12360
  • [34] Assessment and Correction of the On-Orbit Radiometric Calibration in FY-3D MERSI-2 Thermal Infrared Channels
    Jiang, Geng-Ming
    Zou, Yi
    Chen, Hao
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60
  • [35] An Inexpensive 3D-Printable Do-It-Yourself Visible Spectrophotometer for Online, Hybrid, and Classroom-Based Learning
    Pap, Levente G.
    JOURNAL OF CHEMICAL EDUCATION, 2021, 98 (08) : 2584 - 2591
  • [36] Simulation of at-sensor radiance over land for proposed thermal channels of Imager payload onboard INSAT-3D satellite using MODTRAN model
    Pandya, M. R.
    Shah, D. B.
    Trivedi, H. J.
    Panigrahy, S.
    JOURNAL OF EARTH SYSTEM SCIENCE, 2011, 120 (01): : 19 - 25
  • [37] The first evaluation of the FY-3D/MERSI-2 sensor's thermal infrared capabilities for deriving land surface temperature in volcanic regions: a case study of Mount Etna
    Aveni, S.
    Blackett, M.
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2022, 43 (08) : 2777 - 2792
  • [38] On-orbit Radiometric Calibration for Thermal Infrared Band of FY3D/MERSI-II Satellite Remote Sensor Based on Qinghai Lake Radiation Calibration Test-site
    Zhang Yun-xiang
    Li Xin
    Zhang Meng
    Kang Qing
    Wei Wei
    Zheng Xiao-bing
    Zhang Yong
    ACTA PHOTONICA SINICA, 2020, 49 (05)